DEK-OV- 5DC/240AC/800 2964623 PHOENIX CONTACT Power solid-state relay terminal block, input: 5 V DC, output:.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

DEK-OV- 5DC/240AC/800 2964623 PHOENIX CONTACT Power solid-state relay terminal block, input: 5 V DC, output:..

DEK-OV- 5DC/240AC/800

2964623

PHOENIX_CONTACT

10

Available

Ship on today

Power solid-state relay terminal block, input: 5 V DC, output: 10 - 253 V AC/800 mA, terminal block width: 6.2 mm

More details


Programmable Logic Controllers Plcs

INTERFACE Signal converters, switching devices, and power supply units - PHOENIX CONTACT

INTERFACE Industrial Relays

* Brand new produt in its original packing covered by the warranties and certifications provided by PHOENIX_CONTACT

QuantityPrice
10+29,28 €
20+28,89 €
*This price is per unit and is the net value (not including taxes if applicable).

Related products

More info



Dimensions

Width6.2 mm
Height80 mm
Depth56 mm

Ambient conditions

Ambient temperature (operation)-20 °C ... 60 °C
Ambient temperature (storage/transport)-20 °C ... 70 °C

Input data

Nominal input voltage UN5 V DC
Input voltage range in reference to UN0.8 ... 1.2
Switching threshold "0" signal in reference to UN≤ 0.4
Switching threshold "1" signal in reference to UN≥ 0.8
Typical input current at UN10.2 mA
Typical response time< 10 ms
Typical turn-off time< 10 ms
Operating voltage displayYellow LED
Type of protectionProtection against polarity reversal
Surge protection
Protective circuit/componentPolarity protection diode
Transmission frequency10 Hz

Output data

Output voltage range10 V AC ... 253 V AC (50/60 Hz)
Limiting continuous current0.8 A (see derating curve)
Maximum inrush current30 A (t = 10 ms)
Min. load current10 mA
Leakage current1.2 mA
Surge current30 A (t = 10 ms)
Max. load value4.5 A2s
Peak offstate voltage600 V (Periodic peak reverse voltage)
Voltage drop at max. limiting continuous current≤ 1 V
Output circuit2-conductor floating, zero voltage switch
Type of protectionRCV circuit
Protective circuit/componentRCV circuit

Connection data, input side

Connection nameInput side
Connection methodScrew connection
Stripping length8 mm
Screw threadM3
Conductor cross section solid0.2 mm² ... 4 mm²
Conductor cross section flexible0.2 mm² ... 2.5 mm²
Conductor cross section AWG24 ... 12
Torque0.5 Nm

General

Test voltage input/output2.5 kV AC
2.5 kV (50 Hz, 1 min.)
Mounting positionany
Assembly instructionsIn rows with zero spacing
Operating mode100% operating factor
DesignationStandards/regulations
Standards/regulationsIEC 60664
EN 50178
IEC 62103
Rated surge voltage/insulationBasic insulation
Pollution degree2
Overvoltage categoryIII

Datasheet - PDF

Title:Language:Size:Type:
PHOENIX CONTACT-2964623-DEK-OV- 5DC/240AC/800English115 KbytesPHOENIX CONTACT-2964623-DEK-OV- 5DC/240AC/800

Reviews (0)