Degree of protection | IP20 |
---|---|
Ambient temperature (operation) | -40 °C ... 80 °C |
Ambient temperature (storage/transport) | -40 °C ... 80 °C |
Altitude | ≤ 2000 m (amsl (above mean sea level)) |
Permissible humidity (operation) | 5 % ... 95 % |
Shock (operation) | 30g (Half-sine / 11 ms / 3x ±X, ±Y, ±Z) |
Vibration (operation) | 5g (10 ... 150 Hz/20 cycles/axis/X, Y, Z) |
EN type | T3 |
---|---|
IEC power supply system | TT |
TN-S | |
Number of ports | One |
Mode of protection | L-N |
L-PE | |
N-PE | |
(L+) - (L-) | |
(L+/L-) - PE | |
Mounting type | DIN rail: 35 mm |
Color | light grey RAL 7035 |
traffic grey A RAL 7042 | |
Housing material | PA 6.6-FR 20% GF |
PA 6.6-FR | |
Degree of pollution | 2 |
Flammability rating according to UL 94 | V-0 |
Type | DIN rail module, two-section, divisible |
Number of positions | 2 |
Surge protection fault message | Optical, remote indicator contact |
Nominal voltage UN | 230 V AC (TN-S) |
---|---|
230 V AC (TT - only in use with RCD) | |
Nominal frequency fN | 50 Hz (60 Hz) |
Maximum continuous voltage UC | 264 V AC |
230 V DC | |
Rated load current IL | 26 A (30 °C) |
Residual current IPE | ≤ 5 µA |
Nominal discharge current In(8/20) µs | 3 kA |
Standby power consumption PC | ≤ 275 mVA (at UREF) |
≤ 300 mVA (at UC) | |
Reference test voltage UREF | 255 V AC |
Combination wave UOC | 6 kV |
Voltage protection level Up(L-N) | ≤ 1.35 kV |
Voltage protection level Up(L-PE) | ≤ 1.5 kV |
Voltage protection level Up(N-PE) | ≤ 1.5 kV |
TOV behavior at UT(L-N) | 440 V AC (5 s / withstand mode) |
440 V AC (120 min / withstand mode) | |
TOV behavior at UT(L-PE) | 440 V AC (5 s / withstand mode) |
440 V AC (120 min / withstand mode) | |
1455 V AC (200 ms / safe failure mode) | |
TOV behavior at UT(N-PE) | 1200 V AC (200 ms / safe failure mode) |
Response time tA(L-N) | ≤ 25 ns |
Response time tA(L-PE) | ≤ 100 ns |
Response time tA(N-PE) | ≤ 100 ns |
Short-circuit current rating ISCCR | 1.5 kA AC |
0.25 kA DC | |
Max. backup fuse with branch wiring | not required |
Maximum backup fuse for through wiring | 25 A (gG / B / C) |
Switching function | N/C contact |
---|---|
Operating voltage | 250 V AC |
125 V DC (200 mA DC) | |
Operating current | 3 A AC |
1 A DC (30 V DC) | |
Connection method | Screw connection |
Conductor cross section flexible | 0.2 mm² ... 2.5 mm² |
Conductor cross section solid | 0.2 mm² ... 4 mm² |
Conductor cross section AWG | 24 ... 12 |
Screw thread | M3 |
Tightening torque | 0.8 Nm |
Stripping length | 8 mm |
Connection method | Screw connection |
---|---|
Conductor cross section flexible | 0.2 mm² ... 2.5 mm² |
Conductor cross section solid | 0.2 mm² ... 4 mm² |
Conductor cross section AWG | 24 ... 12 |
Screw thread | M3 |
Tightening torque | 0.8 Nm |
Stripping length | 8 mm |
SPD Type | 4CA |
---|---|
Maximum continuous operating voltage MCOV | 255 V AC |
230 V DC | |
Nominal voltage | 230 V DC |
Rated load current IL | 25 A |
Mode of protection | L-N |
L-G | |
N-G | |
(L+) - (L-) | |
(L+) - G | |
(L-) - G | |
Power distribution system | Single phase |
Nominal frequency | 50/60 Hz |
Measured limiting voltage MLV (L-N) | 1290 V |
Measured limiting voltage MLV (L-G) | 1310 V |
Measured limiting voltage MLV (N-G) | 1310 V |
Measured limiting voltage MLV (L+) - (L-) | 1290 V |
Measured limiting voltage MLV (L+) - G | 1310 V |
Measured limiting voltage MLV (L-) - G | 1310 V |
Nominal discharge current In | 3 kA |
Tightening torque | 5 lbf-in. ... 7 lbf-in. |
---|---|
Conductor cross section AWG | 14 ... 12 |
REACh SVHC | Lead 7439-92-1 |
---|---|
China RoHS | Environmentally Friendly Use Period = 50 |
For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |
Title: | Size: | Type: |
---|---|---|
PDF CATALOG PHOENIX PROTECTION EN.pdf | 27 Mbytes | |
PHOENIX CONTACT-2905229-PLT-SEC-T3-230-FM | 326 Kbytes |
No customer reviews for the moment.
Rating: | |
Name: | |
Email: | |
Subject: | |
Text: | |
Do you recommend this product to buy? | |
Add review |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.