OPT-60DC/ 24DC/ 5 2982126 PHOENIX CONTACT Plug-in miniature solid-state relay, power solid-state relay, 1 N/.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

OPT-60DC/ 24DC/ 5 2982126 PHOENIX CONTACT Plug-in miniature solid-state relay, power solid-state relay, 1 N/..

OPT-60DC/ 24DC/ 5

2982126

PHOENIX_CONTACT

10

Available

Ship on today

Plug-in miniature solid-state relay, power solid-state relay, 1 N/O contact, input: 60 V DC, output: 3 - 33 V DC/5 A

More details


Programmable Logic Controllers Plcs

INTERFACE Signal converters, switching devices, and power supply units - PHOENIX CONTACT

INTERFACE Industrial Relays

* Brand new produt in its original packing covered by the warranties and certifications provided by PHOENIX_CONTACT

QuantityPrice
10+13,59 €
20+13,26 €
30+13,10 €
40+13,05 €
*This price is per unit and is the net value (not including taxes if applicable).

Related products

More info



Dimensions

Width12.7 mm
Height29 mm
Depth15.7 mm

Ambient conditions

Ambient temperature (operation)-25 °C ... 60 °C
Ambient temperature (storage/transport)-25 °C ... 70 °C

Input data

Nominal input voltage UN60 V DC
Input voltage range in reference to UN0.9 ... 1.1
Switching threshold "0" signal, voltage≤ 20 V DC
Switching threshold "1" signal voltage≥ 35 V DC
Typical input current at UN3 mA
Typical response time25 µs
Typical turn-off time400 µs
Type of protectionProtection against polarity reversal
Protective circuit/componentPolarity protection diode
Transmission frequency300 Hz

Output data

Output nominal voltage24 V DC
Output voltage range3 V DC ... 33 V DC
Limiting continuous current5 A (see derating curve)
Maximum inrush current15 A (10 ms)
Surge voltage protection> 33 V DC
Voltage drop at max. limiting continuous current≤ 200 mV
Output circuit2-wire, floating
Type of protectionProtection against polarity reversal
Surge protection
Protective circuit/componentPolarity protection diode

General

Test voltage input/output2.5 kV (50 Hz, 1 min.)
Mounting positionany
Assembly instructionsIn rows with zero spacing
Operating mode100% operating factor
Degree of protectionRT III (wash-proof)
Flammability rating according to UL 94V0
DesignationStandards/regulations
Standards/regulationsIEC 60664
EN 50178
IEC 62103
Rated surge voltage/insulationBasic insulation
Rated insulation voltage100 V DC
Pollution degree2
Overvoltage categoryIII

Datasheet - PDF

Title:Language:Size:Type:
PHOENIX CONTACT-2982126-OPT-60DC/ 24DC/ 5English120 KbytesPHOENIX CONTACT-2982126-OPT-60DC/ 24DC/ 5

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review