HC-MOT-AFL-SET 1409053 PHOENIX CONTACT Connector on motor side, EMC metal housing attachment incl. crimp con.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

HC-MOT-AFL-SET 1409053 PHOENIX CONTACT Connector on motor side, EMC metal housing attachment incl. crimp con..

HC-MOT-AFL-SET

1409053

PHOENIX_CONTACT

Available

Ship on today

Connector on motor side, EMC metal housing attachment incl. crimp contact insert, with flat seal and coated protective cover, without crimp contacts, housing with coatable thick-layer passivation

More details


Core End Sleeves Cable Crimp

PLUSCON Field cabling - PHOENIX CONTACT

Appliance plug connectors - PLUSCON device - PHOENIX CONTACT

* Brand new produt in its original packing covered by the warranties and certifications provided by PHOENIX_CONTACT

QuantityPrice
1+28,33 €
8+25,51 €
15+24,95 €
22+24,65 €
29+24,47 €
*This price is per unit and is the net value (not including taxes if applicable).

Related products

More info



General

Pollution degree3
Overvoltage categoryIII
Insertion/withdrawal cycles≥ 100
TypeMOT
Conductor cross section0.35 mm² ... 2.5 mm² (Power crimp contacts)
0.14 mm² ... 1 mm² (Control crimp contacts)
Connection cross section AWG20 ... 14 (Power crimp contacts)
26 ... 18 (Control crimp contacts)
Stripping length of the individual wire6 mm (Power crimp contacts)
4.5 mm (Control crimp contacts)

Ambient conditions

Ambient temperature (operation)-30 °C ... 100 °C
Degree of protectionIP67

Material data

Flammability rating according to UL 94V0
Seal materialEPDM
Housing materialGD-Zn
Contact materialCopper alloy
Contact surface materialAu
Material of contact surface, power contactAu
Material of contact surface, control contactAu
Contact carrier materialPA

Electrical characteristics

Rated voltage for power contacts400/800 V
Rated voltage (III/3)250 V (Signal)
Rated surge voltage6 kV (Phase/housing power circuit)
8 kV (Phase/phase power circuit)
4 kV (Control circuit)
Rated current16.5 A (power contacts)
2.5 A (control contacts)

Technical data according to UL approval

Nominal voltage, power contact600 V
Nominal current, power contact16.5 A
Nominal voltage, signal contact250 V
Nominal current, signal contact2.5 A

Datasheet - PDF