NBC-M12MSA/ 3,0-93E D-NL 1094446 PHOENIX CONTACT Network cable, 4-position, PUR, water blue RAL 5021, Plug s..

NBC-M12MSA/ 3,0-93E D-NL

1094446

PHOENIX_CONTACT

50

Product on demand only, returns will not be accepted.

Network cable, 4-position, PUR, water blue RAL 5021, Plug straight M12, coding: A-coded, on free cable end, cable length: 3 m

Network cable, 4-pole, PUR, blue water RAL 5021, M12 straight connector, coding: A-encoded, free cable end, cable length: 3 m

More details


Sensors > Sensor-actuator patch cord

Industrial Field Connectivity (IFC)

Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX_CONTACT

* This article may be obsolete. Ask for a quotation and we will check if there are any units available. If not, one of our technicians will look for an alternative solution.

If our price is not the best, please ask us for a quote. Ask for a quotation

Best sellers

More info



Key Commercial Data

Orderkey1094446
Packing unit1
GTIN4055626918143
Custom tariff number85444290

Drawings



Dimensional drawing

Dimensional drawing
Plug, M12 x 1, straight, shielded

Cable cross section

Cable cross section
PUR ETHERNET 2x2 FLEX [93E]



Back to top

Dimensions

Length of cable3 m
Back to top

Ambient conditions

Ambient temperature (operation)-25 °C ... 60 °C (cable, fixed installation)
-5 °C ... 60 °C (cable, flexible installation)
Back to top

General data

Rated voltage48 V AC
60 V DC
Number of positions4
Overvoltage categoryI
Degree of pollution3
Contact materialCuSn
Contact carrier materialPA 6.6
Contact surface materialNi/Au
Back to top

Characteristics head 1

Head typePlug straight M12
No. of positions (pin connector pattern)4 (4)
CodingA-coded
Shieldedyes
Back to top

Characteristics head 2

Head typefree cable end
Back to top

Standards and Regulations

Flammability rating according to UL 94V2
Back to top

Cable

Cable typePUR ETHERNET 2x2 FLEX
Cable type (abbreviation)93E
UL AWM style20963 (80°C/30 V)
Signal type/categoryEthernet CAT5 (IEC 11801), 100 Mbps
Cable structure2x2xAWG26/7; SF/UTP
Conductor cross section2x 2x 0.14 mm²
AWG signal line26
Conductor structure signal line7x 0.16 mm
Core diameter including insulation0.98 mm
Wire colorswhite/orange-orange, white/green-green
Twisted pairs2 cores to the pair
Overall twistTwo pairs with two fillers to the core
ShieldingAluminum-coated foil, tinned copper braided shield
Optical shield covering70 %
External sheath, colorwater blue RAL 5021
Outer sheath thickness1.2 mm
External cable diameter D6.4 mm ±0.2 mm
Minimum bending radius, fixed installation4 x D
Minimum bending radius, flexible installation8 x D
Tensile strength GRP≤ 80 N
Cable weight42 kg/km
Outer sheath, materialPUR
Material conductor insulationFoamed PE
Conductor materialBare Cu litz wires
Standards/specificationsElectrical requirements EN 50288-2-2
Insulation resistance≥ 500 MΩ*km
Loop resistance≤ 290.00 Ω/km
Cable capacityapprox. 45 nF/km (at 1 kHz)
Wave impedance100 Ω ±5 Ω (at 100 MHz)
Near end crosstalk attenuation (NEXT)65.3 dB (with 1 MHz)
56.3 dB (at 4 МHz)
50.3 dB (at 10 MHz)
47.2 dB (at 16 MHz)
45.8 dB (at 20 МHz)
42.9 dB (at 31.25 МHz)
38.4 dB (at 62.5 МHz)
35.3 dB (at 100 MHz)
Power-summated near end crosstalk attenuation (PSNEXT)62.3 dB (with 1 MHz)
53.3 dB (at 4 МHz)
47.3 dB (at 10 MHz)
44.2 dB (at 16 MHz)
42.8 dB (at 20 МHz)
39.9 dB (at 31.25 МHz)
35.4 dB (at 62.5 МHz)
32.3 dB (at 100 MHz)
Attenuation3.2 dB (with 1 MHz)
6 dB (at 4 МHz)
9.5 dB (at 10 MHz)
12.1 dB (at 16 MHz)
13.6 dB (at 20 МHz)
17.1 dB (at 31.25 МHz)
24.8 dB (at 62.5 МHz)
32 dB (at 100 MHz)
Return loss (RL)23 dB (at 4 МHz)
24.1 dB (at 8 МHz)
25 dB (at 10 MHz)
25 dB (at 16 MHz)
25 dB (at 20 МHz)
23.6 dB (at 31.25 МHz)
21.5 dB (at 62.5 МHz)
20.1 dB (at 100 MHz)
Signal runtime5.3 ns/m
Coupling resistance≤ 100.00 mΩ/m (at 10 MHz)
Nominal voltage, cable≤ 100 V (Peak value, not for high-power applications)
Test voltage Core/Core700 V (50 Hz, 1 min.)
Test voltage Core/Shield700 V (50 Hz, 1 min.)
Current carrying capacity of cable2 A (according to DIN VDE 0891-1)
Flame resistanceaccording to IEC 60332-1-2
in acc. to UL VW1
Halogen-freeaccording to IEC 60754-1
Resistance to oilaccording to EN 60811-2-1
Ambient temperature (operation)-40 °C ... 80 °C (cable, fixed installation)
-20 °C ... 80 °C (cable, flexible installation)
Ambient temperature (installation)-20 °C ... 80 °C
Ambient temperature (storage/transport)-20 °C ... 80 °C
Back to top

Classifications

eCl@ss

eCl@ss 9.027060308
Back to top

ETIM

ETIM 6.0EC001262
ETIM 7.0EC001262
Back to top

ETIM for 1094446 Sensors (EC001855)
Feature Name Feature Value
Number of poles (EF001391) 4
Type of electrical connection, field-sided (EF005525) Other
Positioning cable feed, field-sided (EF005928) Other
Type of electrical connection, box-sided (EF005524) M12
Type of plug-in contact, box-sided (EF008386) Male (plug)
Positioning cable feed, box-sided (EF005927) Straight
Cable length (EF000536) 3 m
Material of cable sheath (EF004136) Other
Halogen free (EF000025) Yes
Colour cable sheath (EF008249) Other
With LED indication (EF005950) No
Screened (EF000881) Yes
Vulcanize (EF004115) No
Material contact body (EF008248) Other
Material of contact surface (EF004020) Other
Permitted cable outer temperature after assembling without vibration (EF001686) -40 °C
Permitted cable outer temperature during assembling/handling (EF001685) -20 °C
Rated voltage (EF000228) 48 V

Datasheet - PDF

Title: Size: Type:
PDF CATALOG PHOENIX CONNECTORS EN.pdf 57 Mbytes

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.