Modbus/TCP(UDP) bus coupler, extreme conditions version, 8 inputs 24 V DC, 4 outputs 24 V DC, 500 mA, complete with I/O connectors

More details


Programmable Logic Controllers Plcs

AUTOMATION Industrial Automation - PHOENIX CONTACT

I/O systems. Connectors - PHOENIX CONTACT

* Brand new produt in its original packing covered by the warranties and certifications provided by PHOENIX_CONTACT

QuantityPrice
1+374,57 €
2+366,32 €
3+363,66 €
*This price is per unit and is the net value (not including taxes if applicable).

Related products

More info



Dimensions

Width80 mm
Height119.8 mm
Depth71.5 mm
Note on dimensionsSpecfications with connectors

Ambient conditions

Ambient temperature (operation)-25 °C ... 55 °C
-40 °C ... 70 °C (Extended, see section “Tested successfully: use under extreme ambient conditions” in the data sheet.)
Ambient temperature (storage/transport)-40 °C ... 85 °C
Permissible humidity (operation)10 % ... 95 % (according to DIN EN 61131-2)
Permissible humidity (storage/transport)10 % ... 95 % (according to DIN EN 61131-2)
Air pressure (operation)70 kPa ... 106 kPa (up to 3000 m above sea level)
Air pressure (storage/transport)70 kPa ... 106 kPa (up to 3000 m above sea level)
Degree of protectionIP20

General

Net weight375 g
Note on weight specificationswith connectors
Mounting typeDIN rail
Diagnostics messagesShort-circuit / overload of the digital outputs Yes
Sensor supply failure Yes
Failure of the actuator supply Yes

Interfaces

Fieldbus systemModbus/TCP (UDP)
DesignationModbus/TCP (UDP)
Connection methodRJ45 socket, auto negotiation
Transmission speed10/100 MBit/s
Transmission physicsEthernet in RJ45 twisted pair
Fieldbus systemLokalbus
DesignationInline local bus
Connection methodInline data jumper
Transmission speed500 kBit/s / 2 MBit/s (Automatic detection, no combined system)

Power supply for module electronics

Connection methodSpring-cage connection
DesignationBus coupler supply UBC; Communications power UL (7.5 V) and the analog supply UANA (24 V) are generated from the bus coupler supply.
Supply voltage24 V DC (via Inline connector)
Supply voltage range19.2 V DC ... 30 V DC (including all tolerances, including ripple)
Current consumptionmax. 0.98 A (from UBK)
Power losstyp. 3 W (entire device)
Communications power UL7.5 V DC
Current consumption0.8 A
Power consumptiontyp. 1.7 W

Inline potentials

Communications power UL7.5 V DC ±5 %
Power supply at ULmax. 0.8 A DC
Main circuit supply UM24 V DC
Supply voltage range UM19.2 V DC ... 30 V DC (including all tolerances, including ripple)
Power supply at UMmax. 8 A DC (Sum of UM + US)
Current consumption from UMmax. 8 A DC
Segment supply voltage US24 V DC
Supply voltage range US19.2 V DC ... 30 V DC (including all tolerances, including ripple)
Power supply at USmax. 8 A DC (Sum of UM + US)
Current consumption from USmax. 8 A DC
I/O supply voltage UANA24 V DC
Supply voltage range UANA19.2 V DC ... 30 V DC (including all tolerances, including ripple)
Power supply at UANAmax. 0.5 A DC

Digital inputs

Input nameDigital inputs
Connection methodInline connector
2, 3-wire
Number of inputs8
Typical response timeapprox. 500 µs
Protective circuitProtection against polarity reversal Suppressor diode
Input characteristic curveIEC 61131-2 type 1
Input voltage24 V DC
Input voltage range "0" signal-30 V DC ... 5 V DC
Input voltage range "1" signal15 V DC ... 30 V DC
Nominal input current at UINtyp. 3 mA
Typical input current per channeltyp. 3 mA
Delay at signal change from 0 to 11.2 ms
Delay at signal change from 1 to 01.2 ms

Digital outputs

Output nameDigital outputs
Connection methodInline connector
2, 3-wire
Number of outputs4
Protective circuitShort-circuit and overload protection Free running circuit
Output voltage24 V DC -1 V (At nominal current)
Nominal output voltage24 V DC
Maximum output current per channel500 mA
Maximum output current per module / terminal block2 A
Maximum output current per module2 A
Nominal load, inductive12 VA (1.2 H; 48 Ω)
Nominal load, lamp12 W
Nominal load, ohmic12 W