MCR-FL-C-UI-2UI-DCI-NC 2814867 PHOENIX CONTACT Signal conditioner View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

MCR-FL-C-UI-2UI-DCI-NC 2814867 PHOENIX CONTACT Signal conditioner

MCR-FL-C-UI-2UI-DCI-NC

2814867

PHOENIX_CONTACT

Signal conditioner

More details


INTERFACE Components (IF)

* Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX_CONTACT

* This article may be obsolete. Ask for a quotation and we will check if there are any units available. If not, one of our technicians will look for an alternative solution.

Go to successor article: MINI MCR-2-UNI-UI-2UI 2905026

If our price is not the best, please ask us for a quote. Ask for a quotation

More info



Key Commercial Data

Orderkey2814867
Packing unit1 pc
NoteMade to Order (non-returnable)
Catalog pagePage 130 (C-7-2015)
GTIN4017918820336
Weight per Piece (excluding packing)117.200 g
Custom tariff number85437090
Country of originDE (Germany)

Dimensions

Width17.5 mm
Height99 mm
Depth114.5 mm

Ambient conditions

Ambient temperature (operation)-25 °C ... 55 °C

Input data

Description of the inputCurrent input
Number of inputs1
Configurable/programmableYes, unconfigured
Current input signal0 mA ... 24 mA (freely selectable in 0.1 mA steps)
Max. input current50 mA
Input resistance current input50 Ω
Description of the inputVoltage input
Configurable/programmableYes, unconfigured
Voltage input signal0 V ... 12 V (freely selectable in 0.1 V steps)
max. input voltage30 V
Input resistance of voltage input200 kΩ

Output data

Output nameCurrent output
Number of outputs2
Configurable/programmableYes, unconfigured
Voltage output signal0 V DC ... 10 V DC
2 V DC ... 10 V DC
0 V DC ... 5 V DC
1 V DC ... 5 V DC
Current output signalsee order key / configuration table
Max. output current35 mA
Load/output load current output≤ 600 Ω
Output nameVoltage output
Configurable/programmableYes, unconfigured
Voltage output signalsee order key / configuration table
Max. output voltage15 V
Load/output load voltage output≥ 10 kΩ

Power supply

Supply voltage range20 V DC ... 30 V DC
Max. current consumption< 25 mA

Connection data

Connection methodScrew connection
Conductor cross section solid min.0.2 mm²
Conductor cross section solid max.2.5 mm²
Conductor cross section AWG min.24
Conductor cross section AWG max.14
Conductor cross section flexible min.0.2 mm²
Conductor cross section flexible max.2.5 mm²
Stripping length8 mm
Screw threadM3

General

No. of channels2
Maximum transmission error≤ 0.15 % (of final value)
Transmission error, typical0.05 % (of final value)
Maximum temperature coefficient< 0.015 %/K
Temperature coefficient, typical0.0075 %/K
Limit frequency (3 dB)30 Hz
Step response (10-90%)12 ms
Protective circuitTransient protection
Test voltage, input/output/supply1.5 kV (50 Hz, 1 min.)
Colorgreen
Housing materialPolyamide PA non-reinforced
Mounting positionany
ConformanceCE-compliant
UL, USA/CanadaClass I, Div. 2, Groups A, B, C, D or Non-Hazardous Locations

Standards and Regulations

Connection in acc. with standardCUL
ConformanceCE-compliant
UL, USA/CanadaClass I, Div. 2, Groups A, B, C, D or Non-Hazardous Locations

Environmental Product Compliance

China RoHSEnvironmentally Friendly Use Period = 50
For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”

Classifications

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.