ANUNCIAR
MINI MCR-EX-IDS-I-I 2908805 PHOENIX CONTACT MINI Analog Signal Conditioner SIL 2 View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

MINI MCR-EX-IDS-I-I 2908805 PHOENIX CONTACT MINI Analog Signal Conditioner SIL 2

MINI MCR-EX-IDS-I-I

2908805

PHOENIX_CONTACT

MINI Analog Signal Conditioner SIL 2

Ex i-Output Signal Conditioner for Separating and Transferring 0mA/4mA Signals... 20 mA from the control system to an intrinsically safe load in the Ex zone. With HART transparency, no-load voltage: 27 V DC, Standard configuration, Safety Integrity Level (SIL, IEC 61508): 3, Screw connection

Ex i-Output signal conditioner for isolating and transmitting 0 mA / 4 mA ... 20 mA signals from the controller to an intrinsically safe load in the Ex area. HART-transparent, no-load voltage: 27 V DC, Standard configuration, Safety Integrity Level (SIL, IEC 61508): 3, Screw connection

More details


Sensors > Isolation amplifier

INTERFACE Components (IF)

Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX_CONTACT

Total: $523.92
Unit price: $523.92
This price is per unit and is the net value (not including taxes if applicable).

If our price is not the best, please ask us for a quote. Ask for a quotation

Best sellers

More info



Technical data

Product properties
Product typeOutput signal conditioner
Product familyMINI Analog Pro
ConfigurationDIP switches
Data management status
Article revision03

System properties
Functionality
ConfigurationDIP switches

Electrical properties
Signal transmission behaviorIn = Out
Step response (10-90%)≤ 10 ms
Maximum temperature coefficient≤ 0.01 %
Maximum transmission error0.1 %
Electrical isolation
Overvoltage categoryII (≤ 5000 m)
Pollution degree2 (≤ 5000 m)
Electrical isolation Input/output/power supply IEC/EN 61010-1
Standards/regulationsIEC/EN 61010-1
Rated insulation voltage300 Vrms
Test voltage2.5 kV AC (50 Hz, 60 s)
InsulationDouble/reinforced insulation
Electrical isolation Output/input, power supply IEC/EN 60079-11
Standards/regulationsIEC/EN 60079-11
Rated insulation voltage253 Vrms
Electrical isolation Input/output/power supply IEC/EN 60079-7
Standards/regulationsIEC/EN 60079-7
Rated insulation voltage251 Vrms
Supply
Nominal supply voltage24 V DC
Supply voltage range19.2 V DC ... 30 V DC
Power consumption≤ 1.2 W

Input data
Signal: Current
Number of inputs1
Current input signal0 mA ... 20 mA
4 mA ... 20 mA (SIL)
Input current≤ 30 mA
Voltage drop< 3.5 V DC (20 mA)

Output data
Signal: Current
Output descriptionintrinsically safe
Number of outputs1
Current output signal0 mA ... 20 mA
4 mA ... 20 mA (SIL)
Load/output load current output≤ 700 Ω (20 mA)
≤ 630 Ω (21 mA)
Output ripple20 mV (rms)
Non-load voltage≤ 27 V DC
Short-circuit-proofyes
Line fault detection> 10 kΩ (Line break)
< 50 Ω (Short circuit)

Connection data
Connection methodScrew connection
Stripping length10 mm
Screw threadM3
Conductor cross section rigid0.2 mm² ... 1.5 mm² (with ferrule)
0.14 mm² ... 2.5 mm² (without ferrule)
Conductor cross section flexible0.14 mm² ... 2.5 mm²
Conductor cross section AWG24 ... 12 (flexible)
Tightening torque0.5 Nm ... 0.6 Nm

Ex data
Ex installation (EPL)Gc
Div. 2
Ex i circuits (EPL)Ga
Da
Ma
Div. 1
Safety data
Max. internal inductance Linegligible
Max. internal capacitance Ci7 nF
Max. output voltage Uo26.4 V
Max. output current Io98 mA
Max. output power Po647 mW
Safety-related maximum voltage Um253 V AC
125 V DC
IIA/I (simple circuit): Max. external inductivity Lo/ Max. external capacitance Co10 mH / 2.48 µF
IIB/III (simple circuit): Max. external inductivity Lo/ Max. external capacitance Co4 mH / 730 nF
IIC (simple circuit): Max. external inductivity Lo/ Max. external capacitance Co2 mH / 89 nF
IIA/I (mixed circuit): Max. external inductivity Lo/ Max. external capacitance Co10 mH / 493 nF, 1 mH / 553 nF, 500 µH / 653 nF, 200 µH / 833 nF, 100 µH / 993 nF
IIB/III (mixed circuit): Max. external inductivity Lo/ Max. external capacitance Co4 mH / 303 nF, 1 mH / 383 nF, 500 µH / 463 nF, 200 µH / 613 nF, 100 µH / 733 nF
IIC (mixed circuit): Max. external inductivity Lo/ Max. external capacitance Co1.4 mH / 42 nF, 1 mH / 49 nF, 500 µH / 66 nF, 200 µH / 89 nF

Interfaces
Data communication (bypass)
Protocols supportedHART-transparent

Signaling
Status displayGreen LED (supply voltage)

Dimensions
Width6.2 mm
Height109.81 mm
Depth119.2 mm

Material specifications
Colorgray (RAL 7042)
Housing materialPBT

Environmental and real-life conditions
Ambient conditions
Ambient temperature (operation)-40 °C ... 70 °C (Any mounting position)
Ambient temperature (storage/transport)-40 °C ... 85 °C
Permissible humidity (operation)5 % ... 95 % (at 25 °C, non-condensing)
Shock (operation)15g (DIN EN 60068-2-27)
Vibration (operation)5g (DIN EN 60068-2-6)
Altitude range (IEC/EN 61010-1)
Height range> 2000 m ... 3000 m
Ambient temperature (operation)-40 °C ... 63 °C
Rated insulation voltage300 Vrms(Input/output/power supply)
InsulationDouble/reinforced insulation
Altitude range (IEC/EN 61010-1)
Height range> 3000 m ... 4000 m
Ambient temperature (operation)-40 °C ... 56 °C
Rated insulation voltage300 Vrms(Input/output/power supply)
InsulationDouble/reinforced insulation
Altitude range (IEC/EN 61010-1)
Height range> 4000 m ... 5000 m
Ambient temperature (operation)-40 °C ... 49 °C
Rated insulation voltage150 Vrms(Input/output/power supply)
InsulationDouble/reinforced insulation
Altitude range (IEC/EN 60079-11)
Height range> 2000 m ... 3000 m
Ambient temperature (operation)-40 °C ... 63 °C
Safety-related maximum voltage Um121 V AC
110 V DC
Rated insulation voltage150 Vrms(Output/input, power supply)
Altitude range (IEC/EN 60079-11)
Height range> 3000 m ... 4000 m
Ambient temperature (operation)-40 °C ... 56 °C
Safety-related maximum voltage Um33 V AC/DC
Rated insulation voltage60 Vrms(Output/input, power supply)
Altitude range (IEC/EN 60079-11)
Height range> 4000 m ... 5000 m
Ambient temperature (operation)-40 °C ... 49 °C
Safety-related maximum voltage Um33 V AC/DC
Rated insulation voltage60 Vrms(Output/input, power supply)
Altitude range (IEC/EN 60079-7)
Height range> 2000 m ... 3000 m
Ambient temperature (operation)-40 °C ... 63 °C
Rated insulation voltage162 Vrms(Input/output/power supply)
Altitude range (IEC/EN 60079-7)
Height range> 3000 m ... 4000 m
Ambient temperature (operation)-40 °C ... 56 °C
Rated insulation voltage60 Vrms(Input/output/power supply)
Altitude range (IEC/EN 60079-7)
Height range> 4000 m ... 5000 m
Ambient temperature (operation)-40 °C ... 49 °C
Rated insulation voltage60 Vrms(Input/output/power supply)

Approvals
CE
CertificateCE-compliant
ATEX
Identification II (1) G [Ex ia Ga] IIC
 II (1) D [Ex ia Da] IIIC
 II 3 (1) G Ex ec [ia Ga] IIC T4 Gc
 I (M1) [Ex ia Ma] I
CertificateBVS 23 ATEX 006 X
IECEx
Identification[Ex ia Ga] IIC
[Ex ia Da] IIIC
Ex ec [ia Ga] IIC T4 Gc
[Ex ia Ma] I
CertificateIECEx BVS 23.0003X
UL, USA/Canada
IdentificationUL 61010-2-201
Safety Integrity Level (SIL, IEC 61508)
Identification3
NoteSingle-channel

EMC data
Electromagnetic compatibilityTested in accordance with the following standards and regulations: EN 61326-1 For industrial use, NAMUR NE 21
Low Voltage DirectiveConformance with Low Voltage Directive
Noise immunityEN 61000-6-2
EN 61326-3-2
Noise emissionEN 61000-6-4

Mounting
Mounting typeDIN rail mounting
Mounting positionany

ETIM for 2908805 Sensors (EC002653)
Feature Name Feature Value
Rated supply voltage DC (EF007078) 19.2 V
Number of input ranges -60 mV ... +60 mV (EF006927) 0
Number of input ranges -100 mV ... +100 mV (EF006912) 0
Number of input ranges -300 mV ... +300 mV (EF006920) 0
Number of input ranges -500 mV ... +500 mV (EF006926) 0
Number of input ranges -1 V ... +1 V (EF006906) 0
Number of input ranges -2 V ... +2 V (EF006913) 0
Number of input ranges -2.5 V ... +2.5 V (EF006915) 0
Number of input ranges -5 V ... +5 V (EF006923) 0
Number of input ranges -10 V ... +10 V (EF006909) 0
Number of input ranges -20 V ... +20 V (EF006917) 0
Number of input ranges 0 mV ... 60 mV (EF006905) 0
Number of input ranges 0 mV ... 100 mV (EF006893) 0
Number of input ranges 0 mV ... 200 mV (EF006898) 0
Number of input ranges 0 mV ... 300 mV (EF006901) 0
Number of input ranges 0 mV ... 500 mV (EF006904) 0
Number of input ranges 0 V ... 1 V (EF006890) 0
Number of input ranges 0 V ... 2 V (EF006894) 0
Number of input ranges 0 V ... 2.5 V (EF006895) 0
Number of input ranges 0 V ... 5 V (EF006903) 0
Number of input ranges 0 V ... 10 V (EF006892) 0
Number of input ranges 0 V ... 20 V (EF006897) 0
Number of input ranges 0 V ... 24 V (EF006899) 0
Number of input ranges 0 V ... 30 V (EF006900) 0
Number of input ranges 1 V ... 5 V (EF006907) 0
Number of input ranges 2 V ... 10 V (EF006914) 0
Number of input ranges +5 V ... -5 V (EF006889) 0
Number of input ranges +10 V ... -10 V (EF006888) 0
Number of input ranges 5 V ... 0 V (EF006924) 0
Number of input ranges 5 V ... 1 V (EF006925) 0
Number of input ranges 10 V ... 0 V (EF006910) 0
Number of input ranges 10 V ... 2 V (EF006911) 0
Number of input ranges 0 mA ... 5 mA (EF006902) 0
Number of input ranges 0 mA ... 10 mA (EF006891) 0
Number of input ranges 0 mA ... 20 mA (EF006896) 0
Number of input ranges 4 mA ... 20 mA (EF006921) 0
Number of input ranges -5 mA ... +5 mA (EF006922) 0
Number of input ranges -10 mA ... +10 mA (EF006908) 0
Number of input ranges -20 mA ... +20 mA (EF006916) 0
Number of input ranges 20 mA ... 0 mA (EF006918) 0
Number of input ranges 20 mA ... 4 mA (EF006919) 0
Number of output ranges -60 mV ... +60 mV (EF006880) 0
Number of output ranges -100 mV ... +100 mV (EF006865) 0
Number of output ranges -300 mV ... +300 mV (EF006873) 0
Number of output ranges -500 mV ... +500 mV (EF006879) 0
Number of output ranges -1 V ... +1 V (EF006859) 0
Number of output ranges -2 V ... +2 V (EF006866) 0
Number of output ranges -2.5 V ... +2.5 V (EF006868) 0
Number of output ranges -5 V ... +5 V (EF006876) 0
Number of output ranges -10 V ... +10 V (EF006862) 0
Number of output ranges -20 V ... +20 V (EF006870) 0
Number of output ranges 0 mV ... 60 mV (EF006858) 0
Number of output ranges 0 mV ... 100 mV (EF006846) 0
Number of output ranges 0 mV ... 200 mV (EF006851) 0
Number of output ranges 0 mV ... 300 mV (EF006854) 0
Number of output ranges 0 mV ... 500 mV (EF006857) 0
Number of output ranges 0 V ... 1 V (EF006843) 0
Number of output ranges 0 V ... 2 V (EF006847) 0
Number of output ranges 0 V ... 2.5 V (EF006848) 0
Number of output ranges 0 V ... 5 V (EF006856) 0
Number of output ranges 0 V ... 10 V (EF006845) 0
Number of output ranges 0 V ... 20 V (EF006850) 0
Number of output ranges 0 V ... 24 V (EF006852) 0
Number of output ranges 0 V ... 30 V (EF006853) 0
Number of output ranges 1 V ... 5 V (EF006860) 0
Number of output ranges 2 V ... 10 V (EF006867) 0
Number of output ranges +5 V ... -5 V (EF006842) 0
Number of output ranges +10 V ... -10 V (EF006841) 0
Number of output ranges 5 V ... 0 V (EF006877) 0
Number of output ranges 5 V ... 1 V (EF006878) 0
Number of output ranges 10 V ... 0 V (EF006863) 0
Number of output ranges 10 V ... 2 V (EF006864) 0
Number of output ranges 0 mA ... 5 mA (EF006855) 0
Number of output ranges 0 mA ... 10 mA (EF006844) 0
Number of output ranges 0 mA ... 20 mA (EF006849) 0
Number of output ranges 4 mA ... 20 mA (EF006874) 0
Number of output ranges -5 mA ... +5 mA (EF006875) 0
Number of output ranges -10 mA ... +10 mA (EF006861) 0
Number of output ranges -20 mA ... +20 mA (EF006869) 0
Number of output ranges 20 mA ... 0 mA (EF006871) 0
Number of output ranges 20 mA ... 4 mA (EF006872) 0
Malfunction message output (EF007499) No
Inherently safe according to EN 60947-5-6 NAMUR (EF007112) No
Height (EF000040) 109.81 mm
Width (EF000008) 6.2 mm
Depth (EF000049) 119.2 mm
Power consumption (EF000346) 1.2 W
Load (EF007096) 700 Ohm
Operating temperature (EF002393) -40 °C
Temperature drift (EF007507) 0.01 %/K
Type of electric connection (EF003961) Screw connection
Mounting method (EF000003) Snap mounting support rail

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.