MCR-EX-IDS-I-I 2908805 PHOENIX CONTACT MINI Analog Signal Conditioner SIL 2 View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

MCR-EX-IDS-I-I 2908805 PHOENIX CONTACT MINI Analog Signal Conditioner SIL 2

MCR-EX-IDS-I-I

2908805

PHOENIX_CONTACT

MINI Analog Signal Conditioner SIL 2

Ex i-Output Signal Conditioner for Separating and Transferring 0mA/4mA Signals... 20 mA from the control system to an intrinsically safe load in the Ex zone. With HART transparency, no-load voltage: 27 V DC, Standard setting, Safety Integrity Level (SIL, IEC 61508): 3, Screw connection

More details


Home > PHOENIX CONTACT

* Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX_CONTACT

Total price: $345.49
Unit price: $345.49

Quantity Price
1+$345.49
2+$338.50
*This price is per unit and is the net value (not including taxes if applicable).

If our price is not the best, please ask us for a quote. Ask for a quotation

Best sellers

More info



Technical data

Item Properties
Product TypeOutput Separator Amplifier
Product FamilyMINI Analog Pro
ConfigurationDIP Switch

System Properties
Functionality
ConfigurationDIP Switch

Electrical Properties
Signal Transmission BehaviorIn = Out
Gradual response (10-90%)≤ 10 ms
Maximum temperature coefficient≤ 0.01%
Maximum Transmission Error0,1 %
Galvanic Separation
Surge CategoryII (≤ 5000 m)
Degree of pollution2 (≤ 5000 m)
Galvanic Separation Input/Output/Power IEC/EN 61010-1
Standards/SpecificationsIEC/EN 61010-1
Sizing Insulation Voltage300 VEff
Test voltage2.5 kV AC (50 Hz, 60 sec)
IsolationDouble/reinforced insulation
Galvanic Separation Input/Output, IEC/EN 60079-11 Power Supply
Standards/SpecificationsIEC/EN 60079-11
Sizing Insulation Voltage253 VEff
Galvanic Separation Input/Output/Power IEC/EN 60079-7
Standards/SpecificationsIEC/EN 60079-7
Sizing Insulation Voltage251 VEff
Feeding
Nominal Supply Voltage24 V DC
Supply voltage19.2 V DC ... 30 V DC
Power Consumption≤ 1.2 W

Input data
Signal: Current
Number of Entries1
Input Signal Current0 mA ... 20 mA
4 mA ... 20 mA (SIL)
Input current≤ 30 mA
Voltage drop< 3.5 V DC (20 mA)

Output Data
Signal: Current
Description of the outputIntrinsic safety
Number of outputs1
Current Output Signal0 mA ... 20 mA
4 mA ... 20 mA (SIL)
Charging/Output Load Current Output≤ 700 Ω (20 mA)
≤ 630 Ω (21 mA)
Output Ripple20 mV (rms)
Open-circuit voltage≤ 27 V DC
Short circuit resistantYes
Line Fault Detection> 10 kΩ (Cable break)
< 50 Ω (Short Circuit)

Connection data
Connection typeScrew connection
Length to be de-insulated10 mm
Screw threadM3
Rigid conductor section0.2 mm² ... 1.5 mm² (with toe cap)
0.14 mm² ... 2.5 mm² (without toe)
Flexible conductor section0.14 mm² ... 2.5 mm²
AWG Conductor Section24 ... 12 (flexible)
Tightening torque0.5 Nm ... 0.6 Nm

Ex Data
Ex Installation (EPL)Gc
Div. 2
Intrinsically safe circuits (EPL)Ga
Gives
Ma
Div. 1
Technical Safety Data
Internal inductance max. Lidespicable
Max. Internal Capacity Ci7 nF
Max. output voltage Uor26.4 V
Max. Output Current Ior98 mA
Max. output power Por647 mW
Maximum safety voltage Um253 V AC
125 V DC
IIA/I (Single Electrical Circuit): External Inductance Max. Lor/ Max. external capacity Cor10 mH / 2.48 μF
IIB/III (single electrical circuit): External inductance max. Lor/ Max. external capacity Cor4 mH / 730 nF
IIC (Single Electrical Circuit): External inductance max. Lor/ Max. external capacity Cor2 mH / 89 nF
IIA/I (Combined Electrical Circuit): External inductance max. Lor/ Max. external capacity Cor10 mH / 493 nF, 1 mH / 553 nF, 500 μH / 653 nF, 200 μH / 833 nF, 100 μH / 993 nF
IIB/III (Combined Electrical Circuit): External inductance max. Lor/ Max. external capacity Cor4 mH / 303 nF, 1 mH / 383 nF, 500 μH / 463 nF, 200 μH / 613 nF, 100 μH / 733 nF
IIC (Combined Electrical Circuit): External inductance max. Lor/ Max. external capacity Cor1.4 mH / 42 nF, 1 mH / 49 nF, 500 μH / 66 nF, 200 μH / 89 nF

Interfaces
Data communication (bypass)
Supported ProtocolsWith HART Transparency

Signage
Status IndicationGreen LED (supply voltage)

Dimensions
Width6.2 mm
Height109.81 mm
Depth119.2 mm

Material Data
Colourgrey (RAL 7042)
Shell materialPBT

Environmental and life-life conditions
Environmental conditions
Ambient Temperature (Service)-40 °C ... 70°C (Discretionary mounting position)
Ambient Temperature (Storage/Transport)-40 °C ... 85 °C
Permissible air humidity (service)5 % ... 95% (at 25°C, non-condensing)
Crashes (in service)15g (DIN EN 60068-2-27)
Vibration (in service)5g (DIN EN 60068-2-6)
Superior range of use (IEC/EN 61010-1)
Height Range> 2000 m ... 3000 m
Ambient Temperature (Service)-40 °C ... 63 °C
Sizing Insulation Voltage300 VEff(Input/Output/Power)
IsolationDouble/reinforced insulation
Superior range of use (IEC/EN 61010-1)
Height Range> 3000 m ... 4000 m
Ambient Temperature (Service)-40 °C ... 56 °C
Sizing Insulation Voltage300 VEff(Input/Output/Power)
IsolationDouble/reinforced insulation
Superior range of use (IEC/EN 61010-1)
Height Range> 4000 m ... 5000 m
Ambient Temperature (Service)-40 °C ... 49 °C
Sizing Insulation Voltage150 VEff(Input/Output/Power)
IsolationDouble/reinforced insulation
Superior application range (IEC/EN 60079-11)
Height Range> 2000 m ... 3000 m
Ambient Temperature (Service)-40 °C ... 63 °C
Maximum safety voltage Um121 V AC
110 V DC
Sizing Insulation Voltage150 VEff(Input/Output, Power)
Superior application range (IEC/EN 60079-11)
Height Range> 3000 m ... 4000 m
Ambient Temperature (Service)-40 °C ... 56 °C
Maximum safety voltage Um33 V AC/DC
Sizing Insulation Voltage60 VEff(Input/Output, Power)
Superior application range (IEC/EN 60079-11)
Height Range> 4000 m ... 5000 m
Ambient Temperature (Service)-40 °C ... 49 °C
Maximum safety voltage Um33 V AC/DC
Sizing Insulation Voltage60 VEff(Input/Output, Power)
Superior Operating Range (IEC/EN 60079-7)
Height Range> 2000 m ... 3000 m
Ambient Temperature (Service)-40 °C ... 63 °C
Sizing Insulation Voltage162 VEff(Input/Output/Power)
Superior Operating Range (IEC/EN 60079-7)
Height Range> 3000 m ... 4000 m
Ambient Temperature (Service)-40 °C ... 56 °C
Sizing Insulation Voltage60 VEff(Input/Output/Power)
Superior Operating Range (IEC/EN 60079-7)
Height Range> 4000 m ... 5000 m
Ambient Temperature (Service)-40 °C ... 49 °C
Sizing Insulation Voltage60 VEff(Input/Output/Power)

Approvals
Ce
CertificateCE Compliance
ATEX
Marked II (1) G [Ex ia Ga] IIC
 II (1) D [Ex ia Da] IIIC
 II 3 (1) G Ex ec [ia Ga] IIC T4 Gc
 I (M1) [Ex ia Ma] I
CertificateBVS 23 ATEX 006 X
IECEx
Marked[Ex ia Ga] IIC
[Ex ia Da] IIIC
Ex ec [ia Ga] IIC T4 Gc
[Ex ia Ma] I
CertificateIECEx BVS 23.0003X
CCC/China-Ex
Marked[Ex ia Ga] IIC
[Ex ia Da] IIIC
Ex ec [ia Ga] IIC T4 Gc
Certificate2023122310117250
UL, USA/Canada
MarkedUL 61010-2-201 Listed
Class I, Div. 1, Groups A, B, C, D
Class II, Div. 1 Groups E, F, G
Class III, Div. 1
Class I, Zone 0, 1, 2, Groups IIC, IIB, IIA
Class I, Div. 2, Groups A, B, C, D T4
Certificate, C.D.-No 97285872
Safety Integrity Level (SIL, IEC 61508)
Marked3
ObservationChannel
INMETRO
Marked[Ex ia Ma] I
[Ex ia Ga] IIC
[Ex ia Da] IIIC
Ex ec [ia Ga] IIC T4 Gc
CertificateDNV 23.0186 X

EMC data
Low Voltage DirectiveIn accordance with the NS directive
Interference resistanceEN 61000-6-2
EN 61326-3-2
Electromagnetic compatibilityTesting according to the following standards and requirements: EN 61326-1 for use in the industrial field, NAMUR NE 21
Interference emissionEN 61000-6-4

assembly
Type of mountingRail mounting
Position for mountingdiscretionary

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.