Product successfully added to your shopping cart
PV-SET 2ST/1000DC/2MPP-SPD-SC
2801317
PHOENIX_CONTACT
1
Surge protection device set
Industry Solutions (IS)
* Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX_CONTACT
Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
Orderkey | 2801317 |
---|---|
Packing unit | 1 pc |
Note | Made to Order (non-returnable) |
Catalog page | Page 60 (C-6-2015) |
GTIN | 4046356761697 |
Weight per Piece (excluding packing) | 2,095.000 g |
Custom tariff number | 85363030 |
Country of origin | DE (Germany) |
Degree of protection | IP65 |
---|---|
IP65 | |
Impact strength | IK08 |
Ambient conditions | A, B |
Ambient temperature (operation) | -30 °C ... 55 °C |
Housing material | Polycarbonate, glass-fiber-reinforced |
---|---|
Cover material | Polycarbonate, transparent |
Connector material | PA |
Flammability rating according to UL 94 | V2 (Gehäuse / Deckel) |
V0 (Steckverbinder) | |
Color | light grey RAL 7035 |
Standards for cearances and creepage distances | EN 50539-11 |
Protection class | II |
Mounting type | Surface/Wall mounting |
Type | Installation housing |
Surge protection fault message | optical |
Direction of action | (L+)-PE & (L-)-PE & (L+)-(L-) |
IEC test classification | PV T1 |
---|---|
PV T2 | |
Rated load current IL | 80 A DC |
Residual current IPE | ≤ 25 µA |
≤ 350 µA | |
Standby power consumption PC | ≤ 25 mVA |
Max. discharge current Imax(8/20) µs | 40 kA |
Nominal discharge current In(8/20) µs | 15 kA |
Voltage protection level Up(L+) - (L-) | ≤ 3.5 kV |
Voltage protection level Up(L+/L-) - PE | ≤ 3.5 kV |
Residual voltage (L+) - (L-) | ≤ 3.5 kV (at In) |
≤ 2.6 kV (at 2 kA) | |
≤ 2.9 kV (at 5 kA) | |
≤ 3.2 kV (at 10 kA) | |
≤ 3.7 kV (at 20 kA) | |
≤ 4.1 kV (at 30 kA) | |
≤ 4.6 kV (at 40 kA) | |
Residual voltage (L+/L-) - PE | ≤ 3.5 kV (at 15 kA) |
≤ 2.6 kV (at 2 kA) | |
≤ 2.9 kV (at 5 kA) | |
≤ 3.2 kV (at 10 kA) | |
≤ 3.7 kV (at 20 kA) | |
≤ 4.1 kV (at 30 kA) | |
≤ 4.6 kV (at 40 kA) | |
Response time tA | ≤ 25 ns |
Max. backup fuse with branch wiring | not required |
Recommended backup fuse maximum | not required |
Open circuit voltage UOCSTC | 830 V DC (Solar generator) |
---|---|
Rated surge voltage resistance Uimp | 6 kV |
Rated insulation voltage Ui | 1000 V DC |
Short-circuit current ISCSTC | 25 A DC (per MPP) |
Connection name | DC input |
---|---|
Connection labeling | IN DC L+/L- |
Connection method | SUNCLIX PV connector |
Connection technology | Spring-cage connection |
Stripping length | 15 mm |
Conductor cross section flexible min. | 2.5 mm² |
Conductor cross section flexible max. | 6 mm² |
Cross section | 6 mm² |
External diameter | 5 mm ... 8 mm |
Cable type | PV1-F cables |
Connection name | DC output |
---|---|
Connection labeling | OUT DC L+/L- |
Connection method | SUNCLIX PV connector |
Connection technology | Spring-cage connection |
Stripping length | 15 mm |
Conductor cross section flexible min. | 2.5 mm² |
Conductor cross section flexible max. | 6 mm² |
Cross section | 6 mm² |
External diameter | 5 mm ... 8 mm |
Cable type | PV1-F cables |
Connection name | UT 16-PE |
---|---|
Connection method | Screw terminal blocks |
Screw thread | M5 |
Torque | 2.5 Nm ... 3 Nm |
Stripping length | 14 mm |
Conductor cross section flexible min. | 16 mm² |
Conductor cross section flexible max. | 25 mm² |
Conductor cross section solid min. | 16 mm² |
Conductor cross section solid max. | 25 mm² |
Conductor cross section AWG min. | 5 |
Conductor cross section AWG max. | 4 |
Switching function | PDT, 1-pos. |
---|---|
Connection method | MC 1,5/3 |
Screw thread | M2 |
Tightening torque | 0.25 Nm |
2 lbf-in. ... 4 lbf-in. | |
Stripping length | 7 mm |
Conductor cross section flexible min. | 0.14 mm² |
Conductor cross section flexible max. | 1.5 mm² |
Conductor cross section solid min. | 0.14 mm² |
Conductor cross section solid max. | 1.5 mm² |
Conductor cross section AWG min. | 30 |
Conductor cross section AWG max. | 14 |
Conductor cross section AWG | 30 ... 14 (UL) |
Maximum operating voltage Umax.AC | 250 V AC |
Maximum operating voltage UmaxDC | 30 V DC |
Max. operating current Imax | 1.5 A AC (250 V AC) |
1.5 A DC (30 V DC) |
Standards/regulations | IEC 61439-2 2011 |
---|---|
EN 61439-2 2011 | |
EN 50539-11 Surge protection |
Title: | Size: | Type: |
---|---|---|
PHOENIX CONTACT-2801317-PV-SET 2ST/1000DC/2MPP-SPD-SC | 110 Kbytes |
No customer reviews for the moment.
Rating: | |
Name: | |
Email: | |
Subject: | |
Text: | |
Do you recommend this product to buy? | |
Add review |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.