PV-SET 2ST/1000DC/2MPP-SPD-SC 2801317 PHOENIX CONTACT Lightning and surge arrester in IP65 housing for prote.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

PV-SET 2ST/1000DC/2MPP-SPD-SC 2801317 PHOENIX CONTACT Lightning and surge arrester in IP65 housing for prote..

PV-SET 2ST/1000DC/2MPP-SPD-SC

2801317

PHOENIX_CONTACT

Available

Ship on today

Lightning and surge arrester in IP65 housing for protecting the DC side of an inverter with two MPP trackers up to 1000 V DC, connection via SUNCLIX plug/socket, plug-in varistors with thermal disconnect device between L+, L-, and ground/PE.

More details


TRABTECH Power and Signal Quality - PHOENIX CONTACT

Industry Solutions (IS)

* Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX_CONTACT

Quantity Price
1+$440.99
2+$428.49
3+$422.83
*This price is per unit and is the net value (not including taxes if applicable).

Related products

More info



Dimensions

Height200 mm
Width200 mm
Depth122 mm
Horizontal pitch9 Div.

Ambient conditions

Degree of protectionIP65
IP65
Impact strengthIK08
Ambient conditionsA, B
Ambient temperature (operation)-30 °C ... 55 °C

General

Housing materialPolycarbonate, glass-fiber-reinforced
Cover materialPolycarbonate, transparent
Connector materialPA
Flammability rating according to UL 94V2 (Gehäuse / Deckel)
V0 (Steckverbinder)
Colorlight grey RAL 7035
Standards for cearances and creepage distancesEN 50539-11
Protection classII
Mounting typeSurface/Wall mounting
TypeInstallation housing
Surge protection fault messageoptical
Direction of action(L+)-PE & (L-)-PE & (L+)-(L-)

Protective circuit

IEC test classificationPV T1
PV T2
Rated load current IL80 A DC
Residual current IPE≤ 25 µA
≤ 350 µA
Standby power consumption PC≤ 25 mVA
Max. discharge current Imax (8/20) µs40 kA
Nominal discharge current In (8/20) µs15 kA
Voltage protection level Up (L+) - (L-)≤ 3.5 kV
Voltage protection level Up (L+/L-) - PE≤ 3.5 kV
Residual voltage (L+) - (L-)≤ 3.5 kV (at In)
≤ 2.6 kV (at 2 kA)
≤ 2.9 kV (at 5 kA)
≤ 3.2 kV (at 10 kA)
≤ 3.7 kV (at 20 kA)
≤ 4.1 kV (at 30 kA)
≤ 4.6 kV (at 40 kA)
Residual voltage (L+/L-) - PE≤ 3.5 kV (at 15 kA)
≤ 2.6 kV (at 2 kA)
≤ 2.9 kV (at 5 kA)
≤ 3.2 kV (at 10 kA)
≤ 3.7 kV (at 20 kA)
≤ 4.1 kV (at 30 kA)
≤ 4.6 kV (at 40 kA)
Response time tA≤ 25 ns
Max. backup fuse with branch wiringNot required
Recommended backup fuse maximumNot required

PV protective circuit DC side

Open circuit voltage UOCSTC830 V DC (Solar generator)
Rated surge voltage resistance Uimp6 kV
Rated insulation voltage Ui1000 V DC
Short-circuit current ISCSTC25 A DC (per MPP)

Input connection

Connection nameDC input
Connection labelingIN DC L+/L-
Connection methodSUNCLIX PV connector
Spring-cage connection
Stripping length15 mm
Conductor cross section flexible min.2.5 mm²
Conductor cross section flexible max.6 mm²
Cross section6 mm²
External diameter5 mm ... 8 mm
Cable typePV1-F cables

Output connection

Connection nameDC output
Connection labelingOUT DC L+/L-
Connection methodSUNCLIX PV connector
Spring-cage connection
Stripping length15 mm
Conductor cross section flexible min.2.5 mm²
Conductor cross section flexible max.6 mm²
Cross section6 mm²
External diameter5 mm ... 8 mm
Cable typePV1-F cables

Connection, equipotential bonding/ground

Connection nameUT 16-PE
Connection methodScrew terminal blocks
Screw threadM5
Torque2.5 Nm ... 3 Nm
Stripping length14 mm
Conductor cross section flexible min.16 mm²
Conductor cross section flexible max.25 mm²
Conductor cross section solid min.16 mm²
Conductor cross section solid max.25 mm²
Conductor cross section AWG min.5
Conductor cross section AWG max.4

Remote indicator contact

Switching functionPDT, 1-pos.
Connection methodMC 1,5/3
Screw threadM2
Tightening torque0.25 Nm
2 lbf-in. ... 4 lbf-in.
Stripping length7 mm
Conductor cross section flexible min.0.14 mm²
Conductor cross section flexible max.1.5 mm²
Conductor cross section solid min.0.14 mm²
Conductor cross section solid max.1.5 mm²
Conductor cross section AWG min.30
Conductor cross section AWG max.14
Conductor cross section AWG30 ... 14 (UL)
Maximum operating voltage Umax. AC250 V AC
Maximum operating voltage Umax DC30 V DC
Max. operating current Imax1.5 A AC (250 V AC)
1.5 A DC (30 V DC)

Standards and Regulations

Standards/regulationsIEC 61439-2 2011
EN 61439-2 2011
EN 50539-11 Surge protection

Datasheet - PDF

Title: Language: Size: Type:
PHOENIX CONTACT-2801317-PV-SET 2ST/1000DC/2MPP-SPD-SC English 110 Kbytes PHOENIX CONTACT-2801317-PV-SET 2ST/1000DC/2MPP-SPD-SC

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

Últimas Opiniones de Nuestros Clientes

Todas las valoraciones que recibimos de los artículos que ofrecemos son reales y están verificadas. Un pequeño gesto, pero de mucho valor. Por eso, te agradecemos ese minuto que inviertes en dejarnos tu opinión y calificación sobre los productos, porque nos ayuda a seguir mejorando y a ofrecerte un servicio de todavía mayor calidad.