PV-SET 2ST/1000DC/2MPP-SPD-SC 2801317 PHOENIX CONTACT Surge protection device set View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

PV-SET 2ST/1000DC/2MPP-SPD-SC 2801317 PHOENIX CONTACT Surge protection device set

PV-SET 2ST/1000DC/2MPP-SPD-SC

2801317

PHOENIX_CONTACT

Surge protection device set

More details


Industry Solutions (IS)

* Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX_CONTACT

* This article may be obsolete. Ask for a quotation and we will check if there are any units available. If not, one of our technicians will look for an alternative solution.

Go to successor article: SOL-SC-1ST-0-DC-2MPPT-1001 2404299

If our price is not the best, please ask us for a quote. Ask for a quotation

More info



Key Commercial Data

Orderkey2801317
Packing unit1 pc
NoteMade to Order (non-returnable)
Catalog pagePage 60 (C-6-2015)
GTIN4046356761697
Weight per Piece (excluding packing)2,095.000 g
Custom tariff number85363030
Country of originDE (Germany)

Dimensions

Height200 mm
Width200 mm
Depth122 mm
Horizontal pitch9 Div.

Ambient conditions

Degree of protectionIP65
IP65
Impact strengthIK08
Ambient conditionsA, B
Ambient temperature (operation)-30 °C ... 55 °C

General

Housing materialPolycarbonate, glass-fiber-reinforced
Cover materialPolycarbonate, transparent
Connector materialPA
Flammability rating according to UL 94V2 (Gehäuse / Deckel)
V0 (Steckverbinder)
Colorlight grey RAL 7035
Standards for cearances and creepage distancesEN 50539-11
Protection classII
Mounting typeSurface/Wall mounting
TypeInstallation housing
Surge protection fault messageoptical
Direction of action(L+)-PE & (L-)-PE & (L+)-(L-)

Protective circuit

IEC test classificationPV T1
PV T2
Rated load current IL80 A DC
Residual current IPE≤ 25 µA
≤ 350 µA
Standby power consumption PC≤ 25 mVA
Max. discharge current Imax(8/20) µs40 kA
Nominal discharge current In(8/20) µs15 kA
Voltage protection level Up(L+) - (L-)≤ 3.5 kV
Voltage protection level Up(L+/L-) - PE≤ 3.5 kV
Residual voltage (L+) - (L-)≤ 3.5 kV (at In)
≤ 2.6 kV (at 2 kA)
≤ 2.9 kV (at 5 kA)
≤ 3.2 kV (at 10 kA)
≤ 3.7 kV (at 20 kA)
≤ 4.1 kV (at 30 kA)
≤ 4.6 kV (at 40 kA)
Residual voltage (L+/L-) - PE≤ 3.5 kV (at 15 kA)
≤ 2.6 kV (at 2 kA)
≤ 2.9 kV (at 5 kA)
≤ 3.2 kV (at 10 kA)
≤ 3.7 kV (at 20 kA)
≤ 4.1 kV (at 30 kA)
≤ 4.6 kV (at 40 kA)
Response time tA≤ 25 ns
Max. backup fuse with branch wiringnot required
Recommended backup fuse maximumnot required

PV protective circuit DC side

Open circuit voltage UOCSTC830 V DC (Solar generator)
Rated surge voltage resistance Uimp6 kV
Rated insulation voltage Ui1000 V DC
Short-circuit current ISCSTC25 A DC (per MPP)

Input connection

Connection nameDC input
Connection labelingIN DC L+/L-
Connection methodSUNCLIX PV connector
Connection technologySpring-cage connection
Stripping length15 mm
Conductor cross section flexible min.2.5 mm²
Conductor cross section flexible max.6 mm²
Cross section6 mm²
External diameter5 mm ... 8 mm
Cable typePV1-F cables

Output connection

Connection nameDC output
Connection labelingOUT DC L+/L-
Connection methodSUNCLIX PV connector
Connection technologySpring-cage connection
Stripping length15 mm
Conductor cross section flexible min.2.5 mm²
Conductor cross section flexible max.6 mm²
Cross section6 mm²
External diameter5 mm ... 8 mm
Cable typePV1-F cables

Connection, equipotential bonding/ground

Connection nameUT 16-PE
Connection methodScrew terminal blocks
Screw threadM5
Torque2.5 Nm ... 3 Nm
Stripping length14 mm
Conductor cross section flexible min.16 mm²
Conductor cross section flexible max.25 mm²
Conductor cross section solid min.16 mm²
Conductor cross section solid max.25 mm²
Conductor cross section AWG min.5
Conductor cross section AWG max.4

Remote indication contact

Switching functionPDT, 1-pos.
Connection methodMC 1,5/3
Screw threadM2
Tightening torque0.25 Nm
2 lbf-in. ... 4 lbf-in.
Stripping length7 mm
Conductor cross section flexible min.0.14 mm²
Conductor cross section flexible max.1.5 mm²
Conductor cross section solid min.0.14 mm²
Conductor cross section solid max.1.5 mm²
Conductor cross section AWG min.30
Conductor cross section AWG max.14
Conductor cross section AWG30 ... 14 (UL)
Maximum operating voltage Umax.AC250 V AC
Maximum operating voltage UmaxDC30 V DC
Max. operating current Imax1.5 A AC (250 V AC)
1.5 A DC (30 V DC)

Standards and Regulations

Standards/regulationsIEC 61439-2 2011
EN 61439-2 2011
EN 50539-11 Surge protection

Classifications

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.