Inline Controller with PROFINET interfaces for coupling to other controllers and systems, with programming options according to IEC 61131-3, complete with plug and labeling field.
Home > PHOENIX CONTACT
Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX_CONTACT
Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
With the ILC 370 PN 2TX-IB, the highly modular Inline Controller range from Phoenix Contact has been extended to include a high-performance PROFINET controller. This controller can be used to extend the field of application of Inline Controllers through to medium-sized applications. With direct integration in the Inline automation system, the compact controller is highly modular and can be adapted to the relevant application requirements. Its integrated PROFINET interfaces enable parameterization and programming using PC WorX automation software according to IEC 61131, and it can also exchange data with OPC servers simultaneously and communicate with TCP/IP-compatible devices.
The Inline Controller range covers a wide performance range. From entry-level versions through to high-end controllers, users can find the right controller for their application. Within the product portfolio, users can choose between controllers with different computing capacities, with or without PROFINET controllers, and with or without GL approval.
| Width | 182 mm |
|---|---|
| Height | 140.5 mm |
| Depth | 71.5 mm |
| Degree of protection | IP20 |
|---|---|
| Ambient temperature (operation) | -25 °C ... 55 °C |
| Ambient temperature (storage/transport) | -25 °C ... 85 °C |
| Permissible humidity (operation) | 10 % ... 95 % (non-condensing) |
| Permissible humidity (storage/transport) | 10 % ... 95 % (non-condensing) |
| Air pressure (operation) | 70 kPa ... 106 kPa (up to 3000 m above sea level) |
| Air pressure (storage/transport) | 70 kPa ... 106 kPa (up to 3000 m above sea level) |
| Shock | 25g, Criterion 1, according to IEC 60068-2-27 |
| Vibration (operation) | 5g, accordance to IEC 60068-2-6 |
| Programming tool | PC WORX |
|---|---|
| Diagnostics tool | DIAG+ from version 1.14 |
| Weight | 440 g |
|---|---|
| Diagnostics display | No |
| Controller redundancy | No |
| Interface | INTERBUS local bus (master) |
|---|---|
| Connection method | Inline data jumper |
| Transmission speed | 500 kBaud / 2 MBaud (can be switched) |
| Interface | Parameterization/programming/diagnostics |
| Connection method | RS-232-C, 6-pos. MINI-DIN socket (PS/2), Ethernet 10/100 (RJ45) |
| Interface | Ethernet 10Base-T/100Base-TX |
| Connection method | RJ45 socket |
| Transmission speed | 10/100 MBit/s |
| Interface | INTERBUS (Slave) |
| Connection method | D-SUB-9 female/D-SUB-9 male |
| Device function | PROFINET-IO controller |
|---|---|
| Specification | Version 1.1 |
| Update rate | min. 1 ms |
| Typical current consumption | 250 mA (no local bus device connected during idling, bus inactive) |
|---|---|
| Supply voltage | 24 V DC ±5 % |
| Supply voltage range | 20.4 V DC ... 30 V DC |
| Residual ripple | ± 5 % |
| Power dissipation | max. 6 W |
| Amount of process data | max. 8192 Bit (INTERBUS-Master) |
|---|---|
| max. 512 Bit (INTERBUS-Slave) | |
| Number of supported devices | max. 512 (in total, of which 254 are remote bus devices/bus segments) |
| Number of local bus devices that can be connected | max. 63 (observe current consumption) |
| Number of devices with parameter channel | max. 62 |
| Number of supported branch terminals with remote bus branch | max. 15 |
| Input name | Digital inputs |
|---|---|
| Number of inputs | 12 |
| Connection method | Inline potential distributor |
| Description of the input | Eight fast inputs, interrupt input |
| Output name | Digital outputs |
| Number of outputs | 4 |
| Connection method | 2, 3, 4-wire |
| Maximum output current per channel | 500 mA |
| Without analog input | yes |
| Without analog output | yes |
| Without pulse direction output | yes |
| Without counter input | yes |
| Programming tool | PC WORX |
|---|---|
| Program memory | typ. 2 Mbyte (170 K instructions (IL)) |
| Mass storage | 4 Mbyte |
| Retentive mass storage | 96 kByte (NVRAM) |
| Number of control tasks | 16 |
| Realtime clock | Integrated (battery backup) |
| Title: | Size: | Type: |
|---|---|---|
| PHOENIX CONTACT-2876915-ILC 370 PN 2TX-IB | 113 Kbytes |
![]() |
No customer reviews for the moment.
| Rating: |
|
| Name: | |
| Email: | |
| Subject: | |
| Text: | |
| Do you recommend this product to buy? | |
|
|
|
| Add review | |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.