Product successfully added to your shopping cart
IB IL CNT-PAC/10
2897046
PHOENIX_CONTACT
10
Module counter compact
Inline, Counter input for 24 V signals: 1, Control input for 24 V signals: 1, Switching output: 1, 24 V DC, 0.5 A, transmission rate on the local bus: 500 kBit/s, protection index: IP20
PLC's > Fieldbus, decentr. periphery - function-/technology module
I/O
Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX_CONTACT
Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
| Order key | 2897046 |
|---|---|
| Packaging unit | 10 pcs |
| Sell key | DRI163 - |
| Minimum Order Quantity | 10 pcs |
| Ean | 4046356139021 |
| Weight per unit (excluding packaging) | 130,000 g |
| Tariff rate number | 85389091 |
| Country of origin | DE (Germany) |
| Restriction of Use | EMC: Class A product, see manufacturer's declaration in the download center |
|---|
| Ambient Temperature (Service) | -25°C ... 55 °C |
|---|---|
| Ambient Temperature (Storage/Transport) | -25 °C ... 85 °C |
| Permissible air humidity (service) | 10 % ... 95 % (according to DIN EN 61131-2) |
| Permissible air humidity (storage/transport) | 10 % ... 95 % (according to DIN EN 61131-2) |
| Air Pressure (Service) | 70 kPa... 106 kPa (up to 3000 m above NN) |
| Air Pressure (Storage/Transport) | 70 kPa... 106 kPa (up to 3000 m above NN) |
| Protection Index | IP20 |
| Type of mounting | Rail |
|---|---|
| net weight | 130 g |
| Observation about weight indications | with connectors |
| Operating Mode | Process Data Service with Two Words |
| Diagnostic messages | Short circuit of sensor power |
| Overloading the sensor power supply |
| Denomination | Bus local Inline |
|---|---|
| Connection type | Inline data handling |
| Transmission speed | 500 kBit/s |
| Transmission Physics | copper |
| Denomination | Logic Supply (UL) |
|---|---|
| Supply voltage | 7.5 V DC (via potential maneuver) |
| Current absorption | typ. 40 mA |
| max. 50 mA | |
| Power Consumption | max. 0.375 W (to UL) |
| Denomination | Segment Circuit Power (U)s) |
| Supply voltage | 24 V DC (via potential maneuver) |
| Current absorption | max. 1 A |
| Denomination Entry | Counter input for 24 V signals |
|---|---|
| Number of Entries | 1 (only one counter input can be used, either for 24 V or 5 V signals) |
| Connection type | Spring-loaded connection |
| Operating Mode | Event counting, frequency/time measurement |
| Input voltage | 24 V DC |
| 30 V DC (maximum) | |
| Input Voltage Range Signal "0" | 0 V DC ... 5 V DC |
| Input Voltage Range Signal "1" | 15 V DC ... 30 V DC |
| Input Frequency | max. 100 kHz |
| Input current | typ. 5 mA |
| Denomination Entry | Counter input for 5 V signals |
| Number of Entries | 1 (only one counter input can be used, either for 24 V or 5 V signals) |
| Connection type | Spring-loaded connection |
| Connection technology | 2 wires (shielded), 5V external power supply |
| Operating Mode | Event counting, frequency/time measurement |
| Input voltage | 5 V DC (Rated Voltage) |
| 8 V DC (maximum) | |
| Input Voltage Range Signal "0" | 0 V ... 1.5 V |
| Input Voltage Range Signal "1" | 3.5 V ... 8 V |
| Input Frequency | max. 100 kHz |
| Input current | typ. 5 mA |
| Input resistance | approx. 1.7 kΩ |
| Denomination Output | Switching Output |
|---|---|
| Connection type | Spring-loaded connection |
| Connection technology | 2 conductors |
| Number of outputs | 1 |
| Name of protection | Short Circuit Protection |
| Overload protection | |
| Output voltage | 24 V DC (Rated Voltage) |
| Output current | max. 0.5 A (Rated Current) |
| Inductive Rated Load | max. 12 VA (1.2 H, 48 Ω) |
| Nominal lamp load | max. 12 W |
| Resistive Load Rating | max. 12 W (48 Ω) |
| Kind of protection | III, IEC 61140, EN 61140, VDE 0140-1 |
|---|
| China RoHS | Time slot for intended use: unlimited = EFUP-e |
|---|---|
| No hazardous substances above thresholds |
| eCl@ss 4.0 | 27250304 |
|---|---|
| eCl@ss 4.1 | 27250304 |
| eCl@ss 5.0 | 27250304 |
| eCl@ss 5.1 | 27242605 |
| eCl@ss 6.0 | 27242605 |
| eCl@ss 7.0 | 27242605 |
| eCl@ss 8.0 | 27242605 |
| eCl@ss 9.0 | 27242605 |
| ETIM 2.0 | EC001433 |
|---|---|
| ETIM 3.0 | EC001601 |
| ETIM 4.0 | EC001601 |
| ETIM 5.0 | EC001601 |
| ETIM 6.0 | EC001601 |
| UNSPSC 6.01 | 43172015 |
|---|---|
| UNSPSC 7.0901 | 43201404 |
| UNSPSC 11 | 43172015 |
| UNSPSC 12.01 | 43201404 |
| UNSPSC 13.2 | 43201404 |
| Feature Name | Feature Value |
|---|---|
| Number of functions (EF003244) | 1 |
| Number of HW-interfaces industrial Ethernet (EF003020) | 0 |
| Number of interfaces PROFINET (EF006932) | 0 |
| Number of HW-interfaces RS-232 (EF003021) | 0 |
| Number of HW-interfaces RS-422 (EF003022) | 0 |
| Number of HW-interfaces RS-485 (EF003023) | 0 |
| Number of HW-interfaces serial TTY (EF003024) | 0 |
| Number of HW-interfaces parallel (EF003026) | 0 |
| Number of HW-interfaces wireless (EF006933) | 0 |
| Number of HW-interfaces USB (EF003025) | 0 |
| Number of HW-interfaces other (EF003027) | 0 |
| With optical interface (EF003028) | No |
| Supporting protocol for EtherCAT (EF017564) | No |
| Supporting protocol for TCP/IP (EF003050) | No |
| Supporting protocol for PROFIBUS (EF003052) | Yes |
| Supporting protocol for CAN (EF003053) | No |
| Supporting protocol for INTERBUS (EF003054) | No |
| Supporting protocol for ASI (EF003051) | No |
| Supporting protocol for KNX (EF003055) | No |
| Supporting protocol for Modbus (EF003057) | No |
| Supporting protocol for Data-Highway (EF003058) | No |
| Supporting protocol for DeviceNet (EF003059) | No |
| Supporting protocol for SUCONET (EF003060) | No |
| Supporting protocol for LON (EF003017) | No |
| Supporting protocol for PROFINET IO (EF007525) | No |
| Supporting protocol for PROFINET CBA (EF007524) | No |
| Supporting protocol for SERCOS (EF006657) | No |
| Supporting protocol for Foundation Fieldbus (EF007522) | No |
| Supporting protocol for EtherNet/IP (EF007521) | No |
| Supporting protocol for AS-Interface Safety at Work (EF007519) | No |
| Supporting protocol for DeviceNet Safety (EF007520) | No |
| Supporting protocol for INTERBUS-Safety (EF006662) | No |
| Supporting protocol for PROFIsafe (EF007526) | No |
| Supporting protocol for SafetyBUS p (EF007527) | No |
| Supporting protocol for other bus systems (EF003062) | No |
| IO link master (EF007298) | No |
| System accessory (EF004118) | Yes |
| Function block restart blockage (EF007212) | No |
| Function block automatic reset (EF007208) | No |
| Contactor control function block (EF007467) | No |
| Function block emergency stop (EF007211) | No |
| Function block contactless working protection installation (EF007209) | No |
| Function block affirm push button (EF007214) | No |
| Function block 2-hand switching (EF007215) | No |
| Function block operating mode selection (EF007210) | No |
| Function block access control (EF007213) | No |
| Degree of protection (IP) (EF005474) | IP20 |
| Fieldbus connection over separate bus coupler possible (EF004002) | Yes |
| Frequency measurement (EF000599) | Yes |
| Suitable for rail mounting (EF003972) | Yes |
| Wall mounting/direct mounting (EF007020) | No |
| Front built-in possible (EF007016) | No |
| Rack-assembly possible (EF007018) | No |
| Suitable for safety functions (EF001597) | No |
| SIL according to IEC 61508 (EF009889) | None |
| Performance level according to EN ISO 13849-1 (EF007399) | None |
| Appendant operation agent (Ex ia) (EF004141) | No |
| Appendant operation agent (Ex ib) (EF004142) | No |
| Explosion safety category for gas (EF003997) | None |
| Explosion safety category for dust (EF003998) | None |
| Title: | Size: | Type: |
|---|---|---|
| PDF CATALOG PHOENIX AUTOMATION EN.pdf | 35 Mbytes |
|
No customer reviews for the moment.
| Rating: |
|
| Name: | |
| Email: | |
| Subject: | |
| Text: | |
| Do you recommend this product to buy? | |
|
|
|
| Add review | |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.