HC-HV06-I-PT-M 1407740 PHOENIX CONTACT HEAVYCON pin insert, HV6 series, 6-pos. + 2 switching contacts + PE, .. View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

HC-HV06-I-PT-M 1407740 PHOENIX CONTACT HEAVYCON pin insert, HV6 series, 6-pos. + 2 switching contacts + PE, ..

HC-HV06-I-PT-M

1407740

PHOENIX_CONTACT

Available Ship on today

HEAVYCON pin insert, HV6 series, 6-pos. + 2 switching contacts + PE, 830 V, push-in connection

More details


PLUSCON Field cabling - PHOENIX CONTACT

Heavy industrial connectors - PLUSCON heavy - PHOENIX CONTACT

* Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX_CONTACT

*This price is per unit and is the net value (not including taxes if applicable).

Related products

More info



General

Connection methodPush-in connection (power contacts)
Push-in connection (control contacts)
Pollution degree3
Overvoltage categoryIII
Number of positions6+2+PE
No. of power contacts6
No. of control contacts2
Insertion/withdrawal cycles≥ 500
TypeB16
Conductor cross section0.14 mm² ... 2.5 mm² (power contacts)
0.14 mm² ... 2.5 mm² (control contacts)
Connection cross section AWG26 ... 14 (power contacts)
26 ... 14 (control contacts)
Stripping length8 mm ... 10 mm (power contacts)
8 mm ... 10 mm (control contacts)
Assembly instructionsCoding also using the CP-HC (1686478) coding profiles. HC-B6../ HC-B10..for two coding profiles. HC-B16../ HC-B24..for four coding profiles.
ConnectionConnectors may only be operated when there is no load/the power is switched off. Can be used for solid wires and stranded wires with ferrule.

Ambient conditions

Ambient temperature (operation)-40 °C ... 125 °C (including heating up of contacts)

Material data

Flammability rating according to UL 94V0
Contact materialCopper alloy
Material of contact surface, power contactAg
Material of contact surface, control contactAg
Contact carrier materialPA
Standards/regulationsPA: Fire protection in rail vehicles - requirement sets R22 and R23 acc. to DIN EN 45545-2 (Risk level HL1 - HL2)
PA: Fire protection in rail vehicles - requirement set R24 acc. to DIN EN 45545-2 (Risk level HL1 - HL3)

Electrical characteristics

Rated voltage (III/3)830 V (power contacts)
500 V (control contacts)
Rated surge voltage8 kV (power contacts)
6 kV (control contacts)
Rated current16 A (power contacts)
16 A (control contacts)

Datasheet - PDF

Title: Language: Size: Type:
PHOENIX CONTACT-1407740-HC-HV06-I-PT-M English 137 Kbytes PHOENIX CONTACT-1407740-HC-HV06-I-PT-M

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

Últimas Opiniones de Nuestros Clientes

Todas las valoraciones que recibimos de los artículos que ofrecemos son reales y están verificadas. Un pequeño gesto, pero de mucho valor. Por eso, te agradecemos ese minuto que inviertes en dejarnos tu opinión y calificación sobre los productos, porque nos ayuda a seguir mejorando y a ofrecerte un servicio de todavía mayor calidad.