HC-M-02-AT-M-25 1421377 PHOENIX CONTACT Module inserts contact HC-M-02-AT-M-25 1421377 View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

HC-M-02-AT-M-25 1421377 PHOENIX CONTACT Module inserts contact HC-M-02-AT-M-25 1421377

HC-M-02-AT-M-25

1421377

PHOENIX_CONTACT

2

Module inserts contact - HC-M-02-AT-M-25 - 1421377

Contact insert module, Pin, Axial screw connection, 1000 V, 100 A, 10 mm2 ... 25 mm2, application: Power

More details


Industrial plug-in connectors/interfaces

Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX_CONTACT

* This article may be obsolete. Ask for a quotation and we will check if there are any units available. If not, one of our technicians will look for an alternative solution.

If our price is not the best, please ask us for a quote. Ask for a quotation

Best sellers

More info



Technical data

Notes
GeneralFor HEAVYCON HC-B6 to B48 housing, snap-in module frame required, axial connection for 4 mm Allen key
GeneralThe axial screw connection must be established using a 4 mm Allen key (for stranded conductors only)

Product properties
Number of positions2
ApplicationPower
Insulation characteristics
Overvoltage categoryIII
Degree of pollution3

Electrical properties
Rated voltage (III/3)1000 V
Rated surge voltage8 kV
Rated current100 A

Material specifications
Flammability rating according to UL 94V0

Cable/line
Stripping length of the individual wire13 mm

Mounting
Assembly instructionsTo ensure correct use, installation in housing with IP54 protection or better is required
Note regarding axial connection technology:
Only for stranded wires. The specified conductor cross sections refer to the geometric cross section of the cable used.
Cables with a geometric cross section which deviates significantly from the nominal cable cross section must be checked before use.
The axial connection technology connection space is designed for fine strand cables according to VDE 0295 Class 5. Deviating cable structures (e.g., Class 6 cables) must be checked before use.
Assembly instructions
Before assembly, ensure that the tapered screw is fully loosened (chamber is open). Cables must not be twisted. The wires must be pushed into the contact chamber as far as they will go (until the insulation touches the contact). Hold the wires in position and tighten using an Allen key. The used wire end must be cut off before reconnection. The terminal screw must only be retightened once to prevent the litz wires from breaking. To prevent damage to the contact, the wire/cable must be mechanically held at an appropriate distance from the connection point (e.g., when used in a plate cut out). For notes on correct execution, see DIN VDE 0100-520:2003-06. Unused connections must be tightened with maximum torque.

Datasheet - PDF

Title: Size: Type:
PDF CATALOG PHOENIX CONNECTORS EN .pdf 58 Mbytes

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.