Product successfully added to your shopping cart
HC-M-01-AT-F-40-PE
1417380
PHOENIX_CONTACT
2
Contact insert module
Connectors > Contact insert for rectangular connectors
Industrial plug-in connectors/interfaces
* Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX_CONTACT
Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
Orderkey | 1417380 |
---|---|
Packing unit | 2 pc |
Minimum order quantity | 2 pc |
Catalog page | Page 563 (C-2-2017) |
GTIN | 4055626112619 |
Weight per Piece (excluding packing) | 89.500 g |
Custom tariff number | 85366990 |
Country of origin | PL (Poland) |
Conductor cross section | 25 mm² ... 70 mm² (The cross section specification refers to the geometric cross section of the cable used) |
---|---|
Connection cross section AWG | 10 ... 00 |
Stripping length of the individual wire | 16 mm |
Tightening torque | 8 Nm (25 mm² ... 70 mm²) |
9 Nm (50 mm²) | |
10 Nm (70 mm²) | |
Contact diameter | 9.5 mm |
Wire diameter including insulation | 12 mm (25 mm²) |
16 mm (40 mm²) | |
Hexagonal socket | WAF 5 |
Insertion/withdrawal cycles | ≥ 500 |
Minimum housing height | 72 mm |
Note | For HEAVYCON HC-B6 to B48 housing (housing height: min. 72 mm), HC-M-B..-MF-... module carrier frame required, axial connection for 5 mm Allen key |
---|---|
The axial screw connection must be established using a 5 mm Allen key (for stranded conductors only) | |
Series | HC-M-HS |
Color | light gray |
Number of module slots | 2 |
Connection method | Axial screw connection |
Contact type | turned |
Flammability rating according to UL 94 | V0 |
Assembly instructions | To ensure correct use, installation in housing with IP54 protection or better is required |
Connection | Note regarding axial connection technology: Only for stranded wires. The specified conductor cross sections refer to the geometric cross section of the cable used. Cables with a geometric cross section which deviates significantly from the nominal cable cross section must be checked before use. The axial connection technology connection space is designed for fine strand cables according to VDE 0295 Class 5. Deviating cable structures (e.g., Class 6 cables) must be checked before use. Assembly instructions Before assembly, ensure that the tapered screw is fully loosened (chamber is open). Cables must not be twisted. The wires must be pushed into the contact chamber as far as they will go (until the insulation touches the contact). Hold the wires in position and tighten using an Allen key. The used wire end must be cut off before reconnection. The terminal screw must only be retightened once to prevent the litz wires from breaking. To prevent damage to the contact, the wire/cable must be mechanically held at an appropriate distance from the connection point (e.g., when used in a plate cut out). For notes on correct execution, see DIN VDE 0100-520:2003-06. Unused connections must be tightened with maximum torque. |
REACh SVHC | Lead 7439-92-1 |
---|---|
China RoHS | Environmentally Friendly Use Period = 50 |
For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |
Title: | Size: | Type: |
---|---|---|
PDF CATALOG PHOENIX CONNECTORS EN.pdf | 57 Mbytes |
No customer reviews for the moment.
Rating: | |
Name: | |
Email: | |
Subject: | |
Text: | |
Do you recommend this product to buy? | |
Add review |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.