RIF-1-RSC-LV-24AC/2X21 2903349 PHOENIX CONTACT Relay Module View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

RIF-1-RSC-LV-24AC/2X21 2903349 PHOENIX CONTACT Relay Module

RIF-1-RSC-LV-24AC/2X21

2903349

PHOENIX_CONTACT

10

Relay Module

More details


INTERFACE Components (IF)

* Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX_CONTACT

Quantity Price
10+$15.22
20+$13.01
30+$12.11
40+$12.02
*This price is per unit and is the net value (not including taxes if applicable).

If our price is not the best, please ask us for a quote. Ask for a quotation

Best sellers

More info



Key Commercial Data

Orderkey2903349
Packing unit10 pc
Catalog pagePage 343 (C-5-2017)
GTIN4046356732826
Weight per Piece (excluding packing)69.400 g
Custom tariff number85364110
Country of originCN (China)

Note

Utilization restrictionEMC: class A product, see manufacturer's declaration in the download area
Type of noteNotes on operation
NoteFBS 2-6... plug-in bridge for the input side (A2) and FBS-2-8... plug-in bridge for the output side (11/21)

Dimensions

Width16 mm
Height89 mm
Depth75 mm

Ambient conditions

Ambient temperature (operation)-40 °C ... 50 °C
Ambient temperature (storage/transport)-40 °C ... 85 °C

Coil side

Nominal input voltage UN24 V AC
Input voltage range in reference to UNsee diagram
Mains frequency50/60 Hz
Typical input current at UN33 mA
Typical response time3 ms ... 12 ms
Typical release time range3 ms ... 20 ms
Coil voltage24 V AC
Protective circuitVaristor
Operating voltage displayYellow LED

Contact side

Contact type2 PDT
Type of switch contactSingle contact
Contact materialAgNi
Maximum switching voltage250 V AC/DC
Minimum switching voltage5 V (at 10 mA)
Min. switching current10 mA (At 5 V)
Maximum inrush current12 A (20 ms, N/O contact)
Limiting continuous current8 A (see diagram)
Interrupting rating (ohmic load) max.192 W (at 24 V DC)
96 W (at 48 V DC)
60 W (at 60 V DC)
44 W (at 110 V DC)
57 W (at 220 V DC)
2000 VA (for 250 V AC)
Switching capacity2 A (at 24 V, DC13)
0.2 A (at 250 V, DC13)
3 A (at 24 V, AC15)
3 A (at 120 V, AC15)
3 A (at 250 V, AC15)

Connection data 1

Connection nameCoil side
Connection methodScrew connection
Stripping length8 mm
Conductor cross section solid0.5 mm² ... 4 mm²
Conductor cross-section solid (2 conductors with same cross section)0.5 mm² ... 2.5 mm²
Conductor cross section flexible0.5 mm² ... 4 mm²
0.5 mm² ... 4 mm² (Ferrule with plastic sleeve)
Conductor cross section flexible (2 conductors with same cross section)0.5 mm² ... 2.5 mm²
0.5 mm² ... 1.5 mm² (TWIN ferrule with plastic sleeve)
Conductor cross section AWG20 ... 10 (solid)
20 ... 12 (flexible)
Torque0.5 Nm ... 0.6 Nm

Connection data 2

Connection nameContact side
Connection methodScrew connection
Stripping length8 mm
Conductor cross section solid0.5 mm² ... 4 mm²
Conductor cross-section solid (2 conductors with same cross section)0.5 mm² ... 2.5 mm²
Conductor cross section flexible0.5 mm² ... 4 mm²
0.5 mm² ... 4 mm² (Ferrule with plastic sleeve)
Conductor cross section flexible (2 conductors with same cross section)0.5 mm² ... 2.5 mm²
0.5 mm² ... 1.5 mm² (TWIN ferrule with plastic sleeve)
Conductor cross section AWG20 ... 10 (solid)
20 ... 12 (flexible)
Torque0.5 Nm ... 0.6 Nm

General

Type of noteNotes on operation
NoteFBS 2-6... plug-in bridge for the input side (A2) and FBS-2-8... plug-in bridge for the output side (11/21)
Test voltage relay winding/relay contact4 kVrms(50 Hz, 1 min.)
Test voltage PDT/PDT2.5 kVrms(50 Hz, 1 min.)
Operating mode100% operating factor
Degree of protectionIP20 (Relay base)
RT III (Relay)
Mechanical service lifeapprox. 107cycles
Service life, electricalsee diagram
Mounting positionany
Assembly instructionsIn rows with zero spacing
Net weight (SAP)69.4 g

Standards and Regulations

Standards/regulationsDIN EN 50178
Rated surge voltage6 kV
InsulationSafe isolation, basic insulation, and 4 kV rated surge voltage between all changeover contacts.
Degree of pollution2
Overvoltage categoryIII
Flammability rating according to UL 94V2

Environmental Product Compliance

China RoHSEnvironmentally Friendly Use Period = 50
For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”

Articles in set

Classifications

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.