PSR-SCP- 24DC/TS/S 2986229 PHOENIX CONTACT Safety module View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

PSR-SCP- 24DC/TS/S 2986229 PHOENIX CONTACT Safety module

PSR-SCP- 24DC/TS/S

2986229

PHOENIX_CONTACT

Safety module

More details


Safety

* Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX_CONTACT

Total price: $1,322.77
Unit price: $1,322.77

Quantity Price
1+$1,322.77
2+$1,322.77
*This price is per unit and is the net value (not including taxes if applicable).

If our price is not the best, please ask us for a quote. Ask for a quotation

More info



Key Commercial Data

Orderkey2986229
Packing unit1 pc
Catalog pagePage 292 (C-6-2017)
GTIN4046356477192
Weight per Piece (excluding packing)154.000 g
Custom tariff number85371098
Country of originDE (Germany)

Note

Utilization restrictionEMC: class A product, see manufacturer's declaration in the download area

Dimensions

Width67.5 mm
Height99 mm
Depth114.5 mm

Ambient conditions

Ambient temperature (operation)-20 °C ... 55 °C
Ambient temperature (storage/transport)-20 °C ... 70 °C
Max. permissible relative humidity (operation)75 % (On average, 85 % occasionally)
Max. permissible humidity (storage/transport)75 % (On average, 85 % occasionally)
Air pressure (operation)70 kPa ... 108 kPa (up to 3000 m above sea level)
Air pressure (storage/transport)66 kPa ... 108 kPa (up to 3500 m above sea level)
Maximum altitudemax. 2000 m (See Appendix "Using PSR-TRISAFE modules at altitudes greater than 2000 m above sea level")

Power supply

Rated control circuit supply voltage US24 V DC (A1/A2)
18 V DC ... 30 V DC (Incl. all tolerances, incl. residual ripple)
Rated control supply current IStyp. 110 mA
Limiting continuous currentmax. 6 A (For looped-through current paths A1/A1 and A2/A2)
Filter timetyp. 20 ms (Load-dependent, in the event of voltage dips at US)
Status display3x LED green, 1x LED red
Protective circuitYes, within the scope of the operating voltage limits

Digital inputs

Description of the inputDigital, type HTL
Number of inputs10 (Two-channel, up to SIL 3)
20 (Single-channel, up to SIL 2)
Input voltage range "0" signal0 V DC ... 5 V DC (for safe Off)
Input voltage range "1" signal11 V DC ... 30 V DC
Current consumptiontyp. 4 mA
Cable lengthmax. 2000 m
Status display20 x LED green (1 LED per input)

Digital outputs

Number of outputs4 (Safe semiconductor outputs, up to Cat. 4 in accordance with EN ISO 13849-1)
2 (Ground switching outputs)
Nominal output voltage24 V DC (Supply via 24 V/0 V)
Nominal output voltage range18 V DC ... 30 V DC (Incl. all tolerances, incl. residual ripple)
Limiting continuous current2 A (Per channel, see Derating)
2 A (Total current of all outputs)
Output voltage< 5 V (Low state)
Leakage currentmax. 2 mA
Max. capacitive loadmax. 1 µF (Electronic components)
Max. inductive loadSee "Protective circuit"
Test pulses< 1 ms
Note on protection circuitYes, within the scope of the operating voltage limits
Short-circuit protectionYes
Status display4 x LED green (1 LED per output)

Clock outputs

Output descriptionDigital
Number of outputs2
Voltage24 V DC (Supply via 24 V/0 V)
Limiting continuous current100 mA
Test pulses< 1 ms
Short-circuit protectionYes

Alarm outputs

Output descriptionDigital
Number of outputs4
Voltage24 V DC (Supply via 24 V/0 V)
Limiting continuous current100 mA
Short-circuit protectionYes

Times

Response timemax. 30 ms (plus response time of PSR-TS-SDOR4)
Recovery time< 10 s

General

Nominal operating mode100% operating factor
Net weight154 g
Mounting positionOn horizontal DIN rail
Mounting typeDIN rail mounting
Degree of protectionIP20
IP54
Min. degree of protection of inst. locationIP54
Housing materialPolyamide PA non-reinforced
Housing coloryellow
Number of possible extension modules1 (Max. continuous current via PSR-TBUS: 4 A)

Connection data

Connection methodScrew connection
pluggableYes
Conductor cross section solid min.0.2 mm²
Conductor cross section solid max.2.5 mm²
Conductor cross section flexible min.0.2 mm²
Conductor cross section flexible max.2.5 mm²
Conductor cross section AWG min.24
Conductor cross section AWG max.12
Stripping length7 mm
Screw threadM3
Torque0.5 Nm ... 0.6 Nm
5 lbf-in. ... 7 lbf-in.

Safety-related characteristic data

Stop category0
DesignationIEC 61508 - High demand
Safety Integrity Level (SIL)2 (1-channel parameterization)
3 (2-channel parameterization)
DesignationIEC 61508 - Low demand
Safety Integrity Level (SIL)2 (1-channel parameterization)
3 (2-channel parameterization)
DesignationEN ISO 13849
Performance level (PL)d (1-channel parameterization)
e (2-channel parameterization)
Category2 (1-channel parameterization)
4 (2-channel parameterization)
DesignationEN 62061
Safety Integrity Level Claim Limit (SIL CL)2 (1-channel parameterization)
3 (2-channel parameterization)
DesignationEN 50156
Safety Integrity Level (SIL)max. 3 (Reference IEC 61508)

Standards and Regulations

DesignationAir clearances and creepage distances between the power circuits
Standards/regulationsDIN EN 50178
Degree of pollution2
Overvoltage categoryIII
Vibration (operation)2g
Shock (operation)10g (Δt = 11 ms, three shocks in each space direction)
10g (Δt = 16 ms, continuous shock, 1000 shocks in each space direction)

Environmental Product Compliance

China RoHSEnvironmentally Friendly Use Period = 50
For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”

Classifications

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.