Key Commercial Data

Orderkey2708193
Packing unit1 pc
NoteMade to Order (non-returnable)
Catalog pagePage 408 (C-8-2013)
GTIN4017918973957
Weight per Piece (excluding packing)120.100 g
Custom tariff number85176200
Country of originDE (Germany)

Note

Utilization restrictionEMC: class A product, see manufacturer's declaration in the download area

Dimensions

Dimensional drawing
Width22.5 mm
Height99 mm
Depth114.5 mm

Ambient conditions

Ambient temperature (operation)-20 °C ... 60 °C
Ambient temperature (storage/transport)-30 °C ... 70 °C
Permissible humidity (operation)10 % ... 95 % (non-condensing)
Altitude5000 m (For restrictions see manufacturer's declaration)
Degree of protectionIP20
Noise immunityEN 61000-6-2:2005

General

Electrical isolationVCC // Ethernet
Test voltage data interface/power supply1500 V
1.5 kVrms(50 Hz, 1 min.)
Electromagnetic compatibilityConformance with EMC Directive 2014/30/EU
Noise emissionEN 50081-2
Net weight120.1 g
Housing materialPA V0
Colorgreen
MTBF564 Years (Telcordia standard, 25°C temperature, 21% operating cycle (5 days a week, 8 hours a day))
136 Years (Telcordia standard, 40°C temperature, 34.25% operating cycle (5 days a week, 12 hours a day))
MTTF885 Years (SN 29500 standard, temperature 25 °C, operating cycle 21 % (5 days a week, 8 hours a day))
446 Years (SN 29500 standard, temperature 40 °C, operating cycle 34.25 % (5 days a week, 12 hours a day))
202 Years (SN 29500 standard, temperature 40 °C, operating cycle 100 % (7 days a week, 24 hours a day))
ConformanceCE-compliant
ATEX II 3 G Ex nA nC IIC T4 Gc X (Please follow the special installation instructions in the documentation!)
UL, USA/Canada508 recognized

Power supply

Nominal supply voltage24 V DC
Supply voltage range18 V DC ... 30 V DC (via pluggable COMBICON screw terminal block)
23 V DC ... 25 V DC (as an alternative or redundant, via backplane bus contact and system current supply)
Typical current consumption≤ 100 mA (24 V DC)
Protective circuitReverse polarity protection
Connection methodPlug-in screw terminal block (COMBICON), redundancy possible

Serial interface

Interface 1Ethernet interface, 10/100Base-T(X) in acc. with IEEE 802.3u
No. of ports1
Connection methodRJ45 socket, shielded
Transmission mediumCopper
Transmission length100 m (shielded twisted pair)
Auto-negotiation modesOptionally transparent via TP and FO (default) or locally on TP
Link throughLink down is automatically forwarded to the second connection
MDI-/MDI-X switchoverBuilt-in switch for line (1:1) and crossover connection
Signal LEDsActivity (yellow), link status (green, UL flashing), 100 Mbps (green)

Optical interface FO

Transmit capacity, minimummin. -8 dBm ((980/1000 µm) static)
min. -19 dBm ((200/230 µm) static)
Transmit capacity, maximummax. -2 dBm ((980/1000 µm) static)
max. -11 dBm ((200/230 µm) static)
Minimum receiver sensitivitymin. -23 dBm ((980/1000 µm) static)
min. -26.8 dBm ((200/230 µm) static)
Wavelength660 nm
Transmission length incl. 3 dB system reserve70 m (Polymer fiber with F-P 980/1000 230 dB/km at 10 Mbps)
300 m (PCF fiber with F-K 200/230 8 dB/km at 10 Mbps)
50 m (Polymer fiber with F-P 980/1000 230 dB/km at 100 Mbps)
100 m (PCF fiber with F-K 200/230 8 dB/km at 100 Mbps)
300 m (HCS GI fiber with F-GK 200/230 at 100 Mbps)
400 m (HCS GI fiber with F-GK 200/230 at 10 Mbps)
Transmission mediumPolymer fiber
PCF fiber
Connection methodSC-RJ

Function

Status and diagnostic indicatorsUL (communications power, green)

Digital outputs

Output nameRelay output
Number of outputs2
Contact typeN/O contact
Maximum switching voltage60 V AC/DC
Max. switching current1 A

Standards and Regulations

Electromagnetic compatibilityConformance with EMC Directive 2014/30/EU
Type of testFree fall in acc. with IEC 60068-2-32
Test result1 m
Type of testVibration resistance in acc. with EN 60068-2-6/IEC 60068-2-6
Test result5g, 150 Hz, 1.5 h, in XYZ direction
Type of testShock in acc. with EN 60068-2-27/IEC 60068-2-27
Test result15g, 11 ms period, half-sine shock pulse
Noise emissionEN 50081-2
Noise immunityEN 61000-6-2:2005
Free from substances that could impair the application of coatingaccording to P-VW 3.10.7 57 65 0 VW-AUDI-Seat central standard
Connection in acc. with standardCUL
Standards/regulationsEN 61000-4-2
Contact discharge± 6 kV (Test Level 3)
Standards/regulationsEN 61000-4-3
Frequency range80 MHz ... 3 GHz (Test Level 3)
Standards/regulationsEN 61000-4-4
CommentsCriterion B
Standards/regulationsEN 61000-4-5
Signal± 2 kV
Standards/regulationsEN 55011
EN 61000-4-6
Frequency range0.15 MHz ... 80 MHz
ConformanceCE-compliant
ATEX II 3 G Ex nA nC IIC T4 Gc X
UL, USA/Canada508 recognized
Noxious gas testISA-S71.04-1985 G3 Harsh Group A

Environmental Product Compliance

China RoHSEnvironmentally Friendly Use Period = 50
For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”

Classifications

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.