Key Commercial Data

Orderkey3006182
Packing unit50 pc
Catalog pagePage 505 (C-1-2017)
GTIN4017918091408
Weight per Piece (excluding packing)44.220 g
Custom tariff number85369010
Country of originCN (China)

General

Number of levels1
Number of connections2
Nominal cross section35 mm²
Colorgray
Insulating materialPA
Flammability rating according to UL 94V2
Maximum load current125 A (with 35 mm² conductor cross section)
Rated surge voltage8 kV
Degree of pollution3
Overvoltage categoryIII
Insulating material groupI
Maximum power dissipation for nominal condition4.06 W
Connection in acc. with standardIEC 60947-7-1
Nominal current IN125 A
Maximum load current125 A (with 35 mm² conductor cross section)
Nominal voltage UN800 V
Open side panelNo
Shock protection test specificationIEC 60529:2001-02
Back of the hand protectionguaranteed
Result of surge voltage testTest passed
Surge voltage test setpoint9.8 kV
Result of power-frequency withstand voltage testTest passed
Power frequency withstand voltage setpoint2 kV
Result of the test for mechanical stability of terminal points (5 x conductor connection)Test passed
Result of bending testTest passed
Bending test rotation speed10 rpm
Bending test turns135
Bending test conductor cross section/weight0.75 mm² / 0.4 kg
35 mm² / 6.8 kg
Tensile test resultTest passed
Conductor cross section tensile test0.75 mm²
Tractive force setpoint30 N
Conductor cross section tensile test35 mm²
Tractive force setpoint190 N
Result of tight fit on supportTest passed
Tight fit on carrierNS 32/NS 35
Setpoint10 N
Result of voltage-drop testTest passed
Requirements, voltage drop≤ 3.2 mV
Result of temperature-rise testTest passed
Short circuit stability resultTest passed
Conductor cross section short circuit testing35 mm²
Short-time current4.2 kA
Result of thermal testTest passed
Proof of thermal characteristics (needle flame) effective duration30 s
Relative insulation material temperature index (Elec., UL 746 B)130 °C
Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21))130 °C
Static insulating material application in cold-60 °C
Behavior in fire for rail vehicles (DIN 5510-2)Test passed
Flame test method (DIN EN 60695-11-10)V0
Oxygen index (DIN EN ISO 4589-2)>32 %
NF F16-101, NF F10-102 Class I2
NF F16-101, NF F10-102 Class F2
Surface flammability NFPA 130 (ASTM E 162)passed
Specific optical density of smoke NFPA 130 (ASTM E 662)passed
Smoke gas toxicity NFPA 130 (SMP 800C)passed
Calorimetric heat release NFPA 130 (ASTM E 1354)28 MJ/kg
Fire protection for rail vehicles (DIN EN 45545-2) R22HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R23HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R24HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R26HL 1 - HL 3

Dimensions

Width15.2 mm
Length55 mm
Height NS 35/7,551 mm
Height NS 35/1558.5 mm
Height NS 3256 mm

Connection data

NoteTerminal point
Conductor cross section solid min.0.75 mm²
Conductor cross section solid max.35 mm²
Conductor cross section flexible min.0.75 mm²
Conductor cross section flexible max.35 mm²
Conductor cross section AWG min.18
Conductor cross section AWG max.2
Conductor cross section flexible, with ferrule without plastic sleeve min.0.75 mm²
Conductor cross section flexible, with ferrule without plastic sleeve max.35 mm²
Conductor cross section flexible, with ferrule with plastic sleeve min.0.75 mm²
Conductor cross section flexible, with ferrule with plastic sleeve max.35 mm²
2 conductors with same cross section, solid min.0.75 mm²
2 conductors with same cross section, solid max.10 mm²
2 conductors with same cross section, stranded min.0.75 mm²
2 conductors with same cross section, stranded max.10 mm²
2 conductors with same cross section, stranded, ferrules without plastic sleeve, min.0.75 mm²
2 conductors with same cross section, stranded, ferrules without plastic sleeve, max.10 mm²
2 conductors with same cross section, stranded, TWIN ferrules with plastic sleeve, min.0.75 mm²
2 conductors with same cross section, stranded, TWIN ferrules with plastic sleeve, max.6 mm²
Connection methodScrew connection
Stripping length16 mm
Screw threadM6
Tightening torque, min3.2 Nm
Tightening torque max3.7 Nm

Standards and Regulations

Connection in acc. with standardCSA
IEC 60947-7-1
Flammability rating according to UL 94V2
Fire protection for rail vehicles (DIN EN 45545-2) R22HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R23HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R24HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R26HL 1 - HL 3

Environmental Product Compliance

China RoHSEnvironmentally friendly use period: unlimited = EFUP-e
No hazardous substances above threshold values

Classifications

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.