EM-CPS-PS/3AC/24DC/5 1064922 PHOENIX CONTACT Primary-switched power supply unit, TRIO POWER, Snap-on connect.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

EM-CPS-PS/3AC/24DC/5 1064922 PHOENIX CONTACT Primary-switched power supply unit, TRIO POWER, Snap-on connect..

EM-CPS-PS/3AC/24DC/5

1064922

PHOENIX_CONTACT

Primary-switched power supply unit, TRIO POWER, Snap-on connection, Cross Power System - installation, input: 3-phase, output: 24 V DC / 5 A

Primary switching power supplies, TRIO POWER, Snap-on connection, Cross Power System: mounting, input:3phase, output: 24 VDC / 5 A

More details


Low-voltage industrial components > DC-power supply

Power Supplies (PS)

Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX_CONTACT

* This article may be obsolete. Ask for a quotation and we will check if there are any units available. If not, one of our technicians will look for an alternative solution.

If our price is not the best, please ask us for a quote. Ask for a quotation

Best sellers

More info



Key Commercial Data

Orderkey1064922
Packing unit1
Catalog pagePage 262 (C-4-2019)
GTIN4055626725222
Custom tariff number85044030

Drawings



Block diagram

Back to top

Note

Utilization restrictionEMC: class A product, see manufacturer's declaration in the download area
Back to top

Dimensions

Width36 mm
Height160 mm
Depth159 mm
Back to top

Ambient conditions

Degree of protectionIP20
Ambient temperature (operation)-25 °C ... 70 °C (> 60 °C Derating: 2.5 %/K)
Ambient temperature (storage/transport)-40 °C ... 85 °C
Max. permissible relative humidity (operation)≤ 95 % (at 25 °C, non-condensing)
Climatic class3K3 (in acc. with EN 60721)
Degree of pollution2
Installation height≤ 4000 m (> 2000 m, Derating: 10 %/1000 m)
Back to top

Input data

Nominal input voltage range3x 400 V AC ... 500 V AC
2x 400 V AC ... 500 V AC
Input voltage range3x 400 V AC ... 500 V AC -20 % ....+15 %
2x 400 V AC ... 500 V AC -10 % ... +15 %
AC frequency range50 Hz ... 60 Hz
Discharge current to PE< 0.25 mA
Current consumption3x 0.4 A (400 V AC)
3x 0.3 A (500 V AC)
2x 0.6 A (400 V AC)
2x 0.5 A (500 V AC)
Nominal power consumption243.6 VA
Inrush current≤ 22 A (typical)
Mains buffering timetyp. 20 ms (400 V AC)
typ. 20 ms (500 V AC)
Input fuse3.15 A (internal (device protection), slow-blow)
Recommended breaker for input protection6 A ... 16 A (AC: Characteristics B, C, D, K)
Power factor (cos phi)0.55
Type of protectionTransient surge protection
Protective circuit/componentVaristor
Back to top

Output data

Nominal output voltage24 V DC ±1 %
Setting range of the output voltage (USet)24 V DC ... 28 V DC (> 24 V DC, constant capacity restricted)
Nominal output current (IN)5 A
Dynamic Boost (IDyn.Boost)7.5 A (5 s)
Derating> 60 °C ... 70 °C (2.5%/K)
Connection in parallelYes, for redundancy and increased capacity
Connection in seriesyes
Protection against overvoltage at the output (OVP)≤ 30 V DC
Control deviation< 1 % (change in load, static 10 % ... 90 %)
< 3 % (Dynamic load change 10 % ... 90 %, 10 Hz)
< 0.1 % (change in input voltage ±10 %)
Residual ripple≤ 20 mVPP
Output power120 W
Typical response time< 1 s
Maximum power dissipation in no-load condition< 1 W (400 V AC)
Power loss nominal load max.< 12 W (480 V AC)
Back to top

General

Net weight0.7 kg
Efficiencytyp. 91 % (400 V AC)
Insulation voltage input/output3 kV AC (type test)
1.5 kV AC (routine test)
Protection classII (in closed control cabinet)
Degree of protectionIP20
MTBF (IEC 61709, SN 29500)> 2300000 h (25 °C)
> 1300000 h (40 °C)
> 620000 h (60 °C)
Assembly instructionsCross Power System
Back to top

Connection data, input

Connection methodSnap-on connection
Back to top

Connection data, output

Connection methodPush-in connection
Conductor cross section solid min.0.2 mm²
Conductor cross section solid max.4 mm²
Conductor cross section flexible min.0.2 mm²
Conductor cross section flexible max.2.5 mm²
Conductor cross section AWG min.24
Conductor cross section AWG max.12
Stripping length10 mm
Back to top

Connection data for signaling

Connection methodPush-in connection
Conductor cross section solid min.0.2 mm²
Conductor cross section solid max.1.5 mm²
Conductor cross section flexible min.0.2 mm²
Conductor cross section flexible max.1.5 mm²
Conductor cross section AWG min.24
Conductor cross section AWG max.16
Stripping length8 mm
Back to top

Standards

EMC requirements for noise immunityEN 61000-6-2
Standard - Safety of transformersEN 61558-2-16 (air clearances and creepage distances only)
Standard - Electrical safetyIEC 61010-1 (SELV)
Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installationsEN 50178/VDE 0160 (PELV)
Standard – Safety extra-low voltageIEC 61010 (SELV) / (PELV)
Standard - Safe isolationDIN VDE 0100-410
Standard – Limitation of mains harmonic currentsEN 61000-3-2
Back to top

Conformance/approvals

UL approvalsUL Listed UL 61010-2-201
Back to top

EMC data

Electromagnetic compatibilityConformance with EMC Directive 2014/30/EU
Low Voltage DirectiveConformance with Low Voltage Directive 2014/35/EC
Conducted noise emissionEN 55016
EN 61000-6-4 (Class A)
Noise emissionEN 55016
EN 61000-6-4 (Class A)
Electrostatic dischargeEN 61000-4-2
Contact discharge6 kV (Test Level 4)
Discharge in air8 kV (Test Level 4)
Electromagnetic HF fieldEN 61000-4-3
Frequency range80 MHz ... 1 GHz
Test field strength10 V/m (Test Level 3)
Frequency range1 GHz ... 2 GHz
Test field strength10 V/m (Test Level 3)
Frequency range2 GHz ... 3 GHz
Test field strength10 V/m (Test Level 3)
CommentsCriterion A
Fast transients (burst)EN 61000-4-4
Input4 kV (Test Level 4 - asymmetrical)
Output2 kV (Test Level 3 - asymmetrical)
Signal1 kV (Test Level 2 - asymmetrical)
CommentsCriterion A
Input3 kV (Test Level 3 - symmetrical)
6 kV (Test Level 4 - asymmetrical)
Output1 kV (Test Level 2 - symmetrical)
2 kV (Test Level 1 - asymmetrical)
Signal1 kV (Test Level 1 - symmetrical)
CommentsCriterion B
Voltage dipsEN 61000-4-11
Voltage230 V AC
Frequency50 Hz
Voltage dip70 %
Number of periods25 periods
Additional textTest Level 2
CommentsCriterion A
Voltage dip40 %
Number of periods10 periods
Additional textTest Level 2
CommentsCriterion A
Voltage dip0 %
Number of periods1 period
Additional textTest Level 2
CommentsCriterion A
Criterion ANormal operating behavior within the specified limits.
Criterion BTemporary impairment to operational behavior that is corrected by the device itself.
Back to top

Environmental Product Compliance

REACh SVHCLead 7439-92-1
Back to top

Classifications

eCl@ss

eCl@ss 6.027049000
eCl@ss 7.027049002
eCl@ss 8.027049002
eCl@ss 9.027040701
Back to top

ETIM

ETIM 5.0EC002540
ETIM 6.0EC002540
ETIM 7.0EC002540
Back to top

Datasheet - PDF

Title: Size: Type:
PDF CATALOG PHOENIX PROTECTION EN .pdf 27 Mbytes

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.