ELR 5030-2 IP PN 2701008 PHOENIX CONTACT Electronic motor starter, electronics module without lower part of .. View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

ELR 5030-2 IP PN 2701008 PHOENIX CONTACT Electronic motor starter, electronics module without lower part of ..

ELR 5030-2 IP PN

2701008

PHOENIX_CONTACT

Electronic motor starter, electronics module without lower part of housing, 2-channel reversing starter

More details


Automation Software (AS)

* Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX_CONTACT

* This article may be obsolete. Ask for a quotation and we will check if there are any units available. If not, one of our technicians will look for an alternative solution.

If our price is not the best, please ask us for a quote. Ask for a quotation

More info



Product description

The PROFINET motor starters are designed as distributed motor starters with IP67 protection. They perform simple drive tasks. The motor starters provide a connection for mains supply and mains continuation as well as one or two connections for a three-phase asynchronous motor.

A complete motor starter consists of three products: motor starter, lower housing part, and Pg screw connection (see accessories).

- 2 integrated CONTACTRON hybrid motor starter with 3.0 kW

- Supported protocols: SNMPv2, TFTP, PROFINET IO, and LLDP

- 2 Ethernet connections

- 10 digital inputs (M12 sockets)

- 4 digital outputs (M12 sockets)

- Stainless steel housing with IP65/IP67 protection

Dimensions

Width384 mm
Height182 mm
Depth139 mm
Note on dimensionsModule electronics without lower part
Drill hole spacing360 mm

Ambient conditions

Ambient temperature (operation)-25 °C ... 50 °C (non-condensing)
Ambient temperature (storage/transport)-25 °C ... 70 °C (non-condensing)
Permissible humidity (operation)0 % ... 85 % (non-condensing)
Permissible humidity (storage/transport)75 % (slight temporary condensation may sometimes appear on the housing)
Air pressure (operation)86 kPa ... 106 kPa (up to 2000 m above mean sea level)
Air pressure (storage/transport)86 kPa ... 106 kPa (up to 2000 m above mean sea level)
Degree of protectionIP67 in acc. with IEC 60529

Interfaces

Fieldbus systemPROFINET
Connection method8-pos. RJ45 socket on motor starter
Designation connection pointX30 and X31
Number of positions8
Permissible conductor cross sectionmax. 0.14 mm² ... 0.22 mm²

Power supply for module electronics

Connection methodCOMBICON
DesignationTerminal strip X13
Number of positions3
Permissible conductor cross section1.5 mm²
Pg screw connectionPg11
Supply voltage24 V DC (US1 / US2)
Supply voltage range20 V DC ... 30 V DC (including ripple)
RipplePermissible ripple 3.6 Vpp within the permissible voltage range
Supply currenttyp. 0.25 A (at US1 = 24 V; plus current of digital inputs/outputs)
Max. current carrying capacity10 A

Mains connection

DesignationMains connection
Connection methodPOWER-COMBICON with silver contacts
Designation connection pointX11
Number of positions5
Permissible conductor cross section2.5 mm² ... 4 mm²
Pg screw connectionPg11
Operating voltage360 V AC ... 550 V AC (line voltage 50/60 Hz)
Max. current carrying capacity25 A

Motor starter, output

Connection methodPOWER-COMBICON
Number2
Designation connection pointTerminal strip; X10 and X12
Permissible conductor cross section2.5 mm² ... 4 mm²
Pg screw connectionPg16
Operating voltage360 V AC ... 550 V AC (line voltage 50/60 Hz)
Frequency range50 Hz ... 60 Hz (mains frequency)
Nominal current range2.4 A ... 6 A
Utilization categoryOn the basis of AC 3
Switching rate5 cycles per minute, maximum

Motor monitoring

Parameterizationvia PROFINET
Parameterization range2.4 A ... 6 A

Digital inputs

Input nameDigital inputs
Number of inputs10
Connection methodM12 connector
2, 3, 4-wire
Number of positions5
Input voltage24 V DC (US1)
Input voltage range "0" signal-3 V DC ... 5 V (binary "0")
Input voltage range "1" signal15 V DC ... 30 V DC (binary "1")
Typical input current per channelapprox. 3 mA (for US1 = 24 V)
Filter time3 ms
Power supply for sensorsUINI = US1 minus 1 V 500 mA Short-circuit/overload protection

Digital outputs

Output nameDigital outputs
Number of outputs4
Connection methodM12 connector
2-wire
Number of positions5
Output currentmax. 500 mA (per channel)
Minimum output voltage with nominal currentUS2 minus 1 V
Type of protectionElectronic short-circuit/overload protection, damping diode

General

Net weight3500 g
Note on weight specificationsModule electronics without lower part
Mounting typeWall mounting
NoteNotes on operation Line protection for the power cable, maximum 25 A. Observe derating of the POWER COMBICON connector
Notes on operation Permitted network type TN network, TT network, IT network available on request

Datasheet - PDF

Title: Size: Type:
PHOENIX CONTACT-2701008-ELR 5030-2 IP PN 110 Kbytes   PHOENIX CONTACT-2701008-ELR 5030-2 IP PN

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.