Product successfully added to your shopping cart
PSR-SCP- 24DC/FSP/1X1/1X2
2981978
PHOENIX_CONTACT
1
Coupling relay
Safety
* Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX_CONTACT
Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
Orderkey | 2981978 |
---|---|
Packing unit | 1 pc |
Catalog page | Page 286 (C-6-2017) |
GTIN | 4046356448352 |
Weight per Piece (excluding packing) | 185.000 g |
Custom tariff number | 85364900 |
Country of origin | DE (Germany) |
Ambient temperature (operation) | -20 °C ... 55 °C (observe derating) |
---|---|
Ambient temperature (storage/transport) | -40 °C ... 70 °C |
Max. permissible relative humidity (operation) | 75 % (on average, 85% infrequently, non-condensing) |
Max. permissible humidity (storage/transport) | 75 % (on average, 85% infrequently, non-condensing) |
Maximum altitude | ≤ 2000 m (Above sea level) |
Rated control circuit supply voltage US | 24 V DC -15 % / +10 % |
---|---|
Rated control supply current IS | typ. 55 mA |
Power consumption at US | typ. 1.32 W |
Inrush current | max. 100 mA |
Typ. starting time with Us | 50 ms |
Typical release time | 50 ms |
Recovery time | 1 s |
Operating voltage display | 1 x yellow LED |
Protective circuit | Surge protection Suppressor diode, 33 V (A1 - A2) |
Maximum switching frequency | 0.5 Hz |
Filter time | max. 5 ms (at A1 in the event of voltage dips at Us) |
max. 2 ms (Test pulse width; high test pulse at A1/A2) | |
≥ 100 ms (Test pulse width; high test pulse at A1/A2) | |
Test pulse rate = 80 x Test pulse width | |
max. 5 ms (Test pulse width; low test pulse at A1/A2) | |
≥ 50 ms (Test pulse rate; low test pulse at A1/A2) | |
Test pulse rate = 15 x Test pulse width |
Contact type | 1 enabling current path |
---|---|
1 confirmation current path | |
Contact material | AgCuNi, + 0.2 µm Au |
Maximum switching voltage | 250 V AC/DC (N/O contact / N/C contact, observe the load curve) |
Minimum switching voltage | 15 V AC/DC (N/O contact / N/C contact) |
Limiting continuous current | 5 A (N/O contact, pay attention to the derating) |
100 mA (N/C contact) | |
Maximum inrush current | 5 A (N/O contact) |
100 mA (N/C contact) | |
Inrush current, minimum | 5 mA (N/O contact / N/C contact) |
Sq. Total current | 25 A2(observe derating) |
Interrupting rating (ohmic load) max. | 120 W (24 V DC, τ = 0 ms, N/C contact: 2.4 W) |
192 W (48 V DC, τ = 0 ms, N/C contact: 4.8 W) | |
162 W (60 V DC, τ = 0 ms, N/C contact: 6 W) | |
66 W (110 V DC, τ = 0 ms, N/C contact: 11 W) | |
60 W (220 V DC, τ = 0 ms, N/C contact: 22 W) | |
1250 VA (250 V AC, τ = 0 ms, N/C contact: 25 VA) | |
Maximum interrupting rating (inductive load) | 72 W (24 V DC, τ = 40 ms, N/C contact: 2.4 W) |
43 W (48 V DC, τ = 40 ms, N/C contact: 4.8 W) | |
41 W (60 V DC, τ = 40 ms, N/C contact: 6 W) | |
35 W (110 V DC, τ = 40 ms, N/C contact: 11 W) | |
48 W (220 V DC, τ = 40 ms, N/C contact: 22 W) | |
Switching capacity | min. 75 mW |
Mechanical service life | 10x 106cycles |
Output fuse | 5 A T fuse (N/O contact) |
150 mA Fast-blow (N/C contact) |
Relay type | Electromechanical relay with forcibly guided contacts in accordance with EN 50205 |
---|---|
Nominal operating mode | 100% operating factor |
Net weight | 185 g |
Mounting position | any |
Mounting type | DIN rail mounting |
Degree of protection | IP20 |
IP54 | |
Min. degree of protection of inst. location | IP54 |
Housing material | PBT |
Housing color | yellow |
Connection method | Screw connection |
---|---|
pluggable | Yes |
Conductor cross section solid min. | 0.2 mm² |
Conductor cross section solid max. | 2.5 mm² |
Conductor cross section flexible min. | 0.2 mm² |
Conductor cross section flexible max. | 2.5 mm² |
Conductor cross section AWG min. | 24 |
Conductor cross section AWG max. | 12 |
Stripping length | 7 mm |
Screw thread | M3 |
Stop category | 0 |
---|---|
Designation | IEC 61508 - High demand |
Safety Integrity Level (SIL) | 3 (max. 10% of the entire SIL; diagnostic coverage (DC) of the control unit at A1/A2 must be ≥ 90% ) |
Designation | IEC 61508 - Low demand |
Safety Integrity Level (SIL) | 3 (max. 10% of the entire SIL; diagnostic coverage (DC) of the control unit at A1/A2 must be ≥ 90% ) |
Designation | EN ISO 13849 |
Performance level (PL) | e (Diagnostic coverage (DC) of the control unit at A1/A2 must be ≥ 99%) |
Category | 4 (Diagnostic coverage (DC) of the control unit at A1/A2 must be ≥ 99%) |
Designation | EN 62061 |
Safety Integrity Level Claim Limit (SIL CL) | 3 (max. 10% of the entire SIL; diagnostic coverage (DC) of the control unit at A1/A2 must be ≥ 90% ) |
Designation | EN 50156 |
Safety Integrity Level (SIL) | 3 |
Designation | Air clearances and creepage distances between the power circuits |
---|---|
Standards/regulations | DIN EN 50178/VDE 0160 |
Rated insulation voltage | 250 V AC |
Rated surge voltage/insulation | Safe isolation, reinforced insulation 6 kV between the control circuits (A1/A2), (21/22), (13/14) |
Degree of pollution | 2 |
Overvoltage category | III |
Shock | 15g |
Vibration (operation) | 10 Hz ... 150 Hz, 2g |
Conformance | CE-compliant |
China RoHS | Environmentally Friendly Use Period = 50 |
---|---|
For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |
Title: | Size: | Type: |
---|---|---|
PDF CATALOG PHOENIX AUTOMATION EN.pdf | 35 Mbytes | |
PHOENIX CONTACT-2981978-PSR-SCP- 24DC/FSP/1X1/1X2 | 164 Kbytes |
No customer reviews for the moment.
Rating: | |
Name: | |
Email: | |
Subject: | |
Text: | |
Do you recommend this product to buy? | |
Add review |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.