SAC-5PY-M/2X10,0-920 1436107 PHOENIX CONTACT Bus system cable View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

SAC-5PY-M/2X10,0-920 1436107 PHOENIX CONTACT Bus system cable

SAC-5PY-M/2X10,0-920

1436107

PHOENIX_CONTACT

Bus system cable

Bus system cable, CANopen®, DeviceNet™, 5-pole halogen-free, shielded, Straight M12 connector, coding: A SPEEDCON, to free cable end and free cable end, cable length: 10 m, Unshielded plug-in connector, The display is placed above pin 1

Bus system cable, CANopen®, DeviceNet™, 5-position, PUR halogen-free, red lilac RAL 4001, shielded, Plug straight M12 SPEEDCON, coding: A, on free cable end and free cable end, cable length: 10 m, Connector unshielded, Shield connected to pin 1

More details


Sensors > Sensor-actuator patch cord

Industrial Field Connectivity (IFC)

Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX_CONTACT

* This article may be obsolete. Ask for a quotation and we will check if there are any units available. If not, one of our technicians will look for an alternative solution.

If our price is not the best, please ask us for a quote. Ask for a quotation

Best sellers

More info



Technical data

Product properties
Product typeData cable preassembled
ApplicationStandard
Sensor typeCANopen®
Number of positions5
Shieldedno
CodingA
Insulation characteristics
Overvoltage categoryII
Degree of pollution3

Interfaces
Bus systemCANopen®/DeviceNet™
Signal type/categoryCANopen®
DeviceNet™

Signaling
Status displayno
Status display presentNo

Electrical properties
Insulation resistance≥ 100 MΩ
Nominal voltage UN48 V AC
60 V DC
Nominal current IN4 A
Transmission mediumCopper

Material specifications
Flammability rating according to UL 94HB
Material of grip bodyTPU, hardly inflammable, self-extinguishing
Contact materialCuSn
Contact surface materialNi/Au
Contact carrier materialTPU GF
Material for screw connectionZinc die-cast, nickel-plated

Dimensions
Dimensional drawingraxgdslpsk.jpg
Center distance21 mm

Connection data
Pin assignment
Contact Color (signal designation) Contact (optional)1 (Distributor) SR (shield)
2 (Distributor) RD (V+)
3 (Distributor) BK (V-)
4 (Distributor) WH (CAN_H)
5 (Distributor) BU (CAN_L)

Connector
Connection 1
TypePlug straight M12 SPEEDCON
Number of positions5
Locking typeSPEEDCON
Coding typeA (Standard)
Ambient temperature (operation)-25 °C ... 90 °C
Connection 2
Typefree cable end
Connection 3
Typefree cable end

Cable/line
Cable length10 m
CANopen®/DeviceNet™, PUR, violet [920]
Dimensional drawingrhrjzbepqc.jpg
Cable weight90 kg/km
UL AWM Style21198 (80°C/300 V)
Number of positions4
Shieldedyes
Cable typeCANopen®/DeviceNet™, PUR, violet [920]
Conductor structure2xAWG24/19+2xAWG22/19
Conductor structure signal line19x 0.13 mm
AWG signal line24
Conductor cross section2x 0.25 mm² (Data cable)
2x 0.34 mm² (Power supply)
1x 0.34 mm² (Drain wire)
Wire diameter incl. insulation1.95 mm ±0.05 mm (Data cable)
1.4 mm ±0.05 mm (Power supply)
External cable diameter6.70 mm ±0.3 mm
Outer sheath, materialPUR
External sheath, colorred lilac RAL 4001
Conductor materialTin-plated Cu litz wires
Material wire insulationFoamed PE (Data cable)
PE (Power supply)
Single wire, colorred-black, blue-white
Twisted pairs2 cores to the pair
Type of pair shieldingPlastic-coated aluminum foil, aluminum side outside
Overall twist2 pairs around a drain wire in the center to the core
Optical shield covering80 %
Insulation resistance≥ 5 GΩ*km (Data cable)
≥ 5 GΩ*km (Power supply)
Loop resistance≤ 181.80 Ω/km (Data cable)
≤ 114.80 Ω/km (Power supply)
Wave impedance120 Ω ±10 % (with 1 MHz)
Cable capacitynom. 40 nF/km (Data cable)
Nominal voltage, cable≤ 300 V (Peak value, not for high-power applications)
Test voltage Core/Core2000 V (50 Hz, 1 min.)
Test voltage Core/Shield2000.00 V (50 Hz, 1 min.)
Minimum bending radius, fixed installation5 x D
Minimum bending radius, flexible installation10 x D
Smallest bending radius, fixed installation34 mm
Smallest bending radius, movable installation67 mm
Dynamic load capacity (bending)Max. bending cycles: 5000000, Bending radius: 70 mm, Bending radius: 10 x D, Traversing path: 4.5 m, Traversing rate: 3 m/s, Acceleration: 3 m/s², Ambient temperature: -20 °C ... 60 °C
Shield attenuation≤ 22.9 dB/km (with 1 MHz)
≤ 16.4 dB/km (At 500 kHz)
≤ 9.5 dB/km (At 125 kHz)
Halogen-freein accordance with DIN VDE 0472 part 815
according to IEC 60754-1
Flame resistanceIEC 60332-1-2
in accordance with ISO 6722-1 5.22 (UN ECE-R 118.01)
Other resistanceLow adhesion
Ambient temperature (operation)-40 °C ... 80 °C (cable, fixed installation)
-30 °C ... 70 °C (Cable, flexible installation)
-20 °C ... 60 °C (for installation)
-20 °C ... 60 °C (cable, drag chain applications)

Environmental and real-life conditions
Ambient conditions
Degree of protectionIP65
IP67

Standards and regulations
Standard designationM12 connector
Standards/specificationsIEC 61076-2-101

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.