VAL-MS/3+0-BE 2881816 PHOENIX CONTACT Base element for type 2 arresters of the VALVETRAB MS product range. V.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

VAL-MS/3+0-BE 2881816 PHOENIX CONTACT Base element for type 2 arresters of the VALVETRAB MS product range. V..

VAL-MS/3+0-BE

2881816

PHOENIX_CONTACT

Available

Ship on today

Base element for type 2 arresters of the VALVETRAB MS product range. Version for 3-phase power supply with PEN conductor.

More details


Overvoltage Protection Over Voltage

TRABTECH Power and Signal Quality - PHOENIX CONTACT

Surge protection - PHOENIX CONTACT

* Brand new produt in its original packing covered by the warranties and certifications provided by PHOENIX_CONTACT

QuantityPrice
1+35,25 €
6+32,26 €
12+31,48 €
17+31,14 €
23+30,88 €
*This price is per unit and is the net value (not including taxes if applicable).

Related products

More info



Dimensions

Height90 mm
Width53.4 mm
Depth44 mm
Horizontal pitch3 Div.

Ambient conditions

Degree of protectionIP20 (only when all terminal points are used)
Ambient temperature (operation)-40 °C ... 80 °C
Ambient temperature (storage/transport)-40 °C ... 80 °C
Altitude≤ 2000 m (amsl (above mean sea level))
Permissible humidity (operation)5 % ... 95 %
Shock (operation)25g
Vibration (operation)5g

General

Standards/specificationsIEC 61643-11 2011
EN 61643-11 2012
IEC test classificationII
T2
EN typeT2
Mounting typeDIN rail: 35 mm
Colorblack
Housing materialPBT
Pollution degree2
Flammability rating according to UL 94V-0
TypeDIN rail module, two-section, divisible
Number of positions3
Surge protection fault messageNone

Additional descriptions

NoteFor installation into a touch protected cabinet. For applications with UC > 500 V distances at the side and distances at the connection area must be minimum of 5 mm between different active parts including earthed parts.

Protective circuit

Nominal frequency fN50 Hz (60 Hz)
Maximum continuous voltage UC800 V AC
Rated load current IL80 A
Short-circuit current rating ISCCR25 kA
Max. backup fuse with branch wiring200 A AC (gG)
Max. backup fuse with V-type through wiring80 A AC (gG)

Connection data

Connection methodScrew connection
Conductor cross section flexible min.1.5 mm²
Conductor cross section flexible max.25 mm²
Conductor cross section solid min.1.5 mm²
Conductor cross section solid max.35 mm²
Conductor cross section AWG15 ... 2
10 ... 2 (UL)
Screw threadM5
Tightening torque4.5 Nm
30 lbf-in. (UL)
Stripping length16 mm

UL specifications

SPD Type4 (for Type 2 applications)