AXC 3050
2700989
PHOENIX_CONTACT
1
Controller
Control Systems (CST)
* Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX_CONTACT
Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
Orderkey | 2700989 |
---|---|
Packing unit | 1 pc |
Catalog page | Page 77 (C-6-2017) |
GTIN | 4046356731201 |
Weight per Piece (excluding packing) | 444.000 g |
Custom tariff number | 85371091 |
Country of origin | DE (Germany) |
Utilization restriction | EMC: class A product, see manufacturer's declaration in the download area |
---|
Degree of protection | IP20 |
---|---|
Ambient temperature (operation) | -25 °C ... 60 °C (up to 2000 m above sea level) |
Ambient temperature (storage/transport) | -40 °C ... 85 °C |
Ambient temperature (assembly) | -5 °C ... 60 °C |
Permissible humidity (operation) | 5 % ... 95 % (according to DIN EN 61131-2) |
Permissible humidity (storage/transport) | 5 % ... 95 % (according to DIN EN 61131-2) |
Air pressure (operation) | 70 kPa ... 106 kPa (up to 3000 m above sea level) |
Air pressure (storage/transport) | 58 kPa ... 106 kPa (up to 4500 m above mean sea level) |
Shock | 30g, 11 ms period, half-sine shock pulse, according to IEC 60068-2-27 |
Vibration (operation) | 5g |
Engineering tool | PC WORX |
---|---|
Programming languages supported | Programming in acc. with IEC 61131-3 |
Diagnostics tool | DIAG+ |
Configuration tool | Config+ Version 1.01 or later |
Engineering tool | PC WORX |
---|---|
Program memory | 4 Mbyte |
Mass storage | 8 Mbyte |
Retentive mass storage | 128 kByte |
Number of control tasks | 16 |
Realtime clock | Yes |
Amount of process data | max. 4096 Bit (Axioline F local bus (input)) |
---|---|
max. 4096 Bit (Axioline F local bus (output)) | |
max. 8192 Bit (internal Modbus /TCP client) | |
Number of supported devices | max. 63 (per station) |
Number of local bus devices that can be connected | max. 63 (observe current consumption) |
Interface | Axioline F local bus |
---|---|
Number | 1 |
Connection method | Bus base module |
Transmission speed | 100 Mbps |
Interface | Ethernet |
Number | 3 |
Connection method | RJ45 socket |
Transmission speed | 10/100 Mbps |
Interface | Parameterization/operation/diagnostics |
Number | 1 |
Connection method | Micro USB type B |
Transmission speed | max. 115.2 kbps |
Interface | Service |
Number | 1 |
Connection method | USB type A, socket |
Device function | PROFINET controller, PROFINET device |
---|---|
Specification | Version 2.3 |
Update rate | max. of 256 devices |
Input name | Counter input for 24 V signals |
---|---|
Number of inputs | max. 2 (via any digital inputs of the Axioline F modules) |
Input frequency | max. 100 kHz (with AXL F DI16/1 HS 1H module) |
Typical current consumption | typ. 408 mA (without I/Os and UL= 24 V) |
---|---|
Max. current consumption | max. 976 mA (with 2 A at UBusfor the I/Os and UL= 24 V) |
Supply voltage | 24 V DC |
Supply voltage range | 19.2 V DC ... 30 V DC |
Residual ripple | ± 5 % |
Power dissipation | max. 9.8 W |
Electromagnetic compatibility | Conformance with EMC Directive 2014/30/EU |
---|---|
Interference emission | Noise emission test according to EN 61000-6-3 Radio interference properties EN 55022 Class A |
Immunity to surge | Noise immunity test in accordance with EN 61000-6-2 Transient overvoltage (surge) EN 61000-4-5/IEC 61000-4-5 Criterion B, DC supply lines: ±0.5 kV/±0.5 kV (symmetrical/asymmetrical), fieldbus cable shield: ±1 kV |
Immunity to burst | Noise immunity test in accordance with EN 61000-6-2 Fast transients (burst) EN 61000-4-4/IEC 61000-4-4 Criterion B, 2 kV |
Immunity to EF | Noise immunity test in accordance with EN 61000-6-2 Electromagnetic fields EN 61000-4-3/IEC 61000-4-3 Criterion A, Field intensity: 10 V/m |
Immunity to ESD | Noise immunity test in accordance with EN 61000-6-2 Electrostatic discharge (ESD) EN 61000-4-2/IEC 61000-4-2 Criterion B, 6 kV contact discharge, 8 kV air discharge |
Immunity to conducted interference | Noise immunity test in accordance with EN 61000-6-2 Conducted interference EN 61000-4-6/IEC 61000-4-6 Criterion A; Test voltage 10 V |
Vibration (storage/transport) | 5g |
Shock | 30g, 11 ms period, half-sine shock pulse, according to IEC 60068-2-27 |
Vibration (operation) | 5g |
Shock (operation) | 10g (Bump endurance test according to DIN EN 60068-2-27) |
China RoHS | Environmentally friendly use period: unlimited = EFUP-e |
---|---|
No hazardous substances above threshold values |
Title: | Size: | Type: |
---|---|---|
PDF CATALOG PHOENIX AUTOMATION EN.pdf | 35 Mbytes | |
PHOENIX CONTACT-2700989-AXC 3050 | 118 Kbytes |
No customer reviews for the moment.
Rating: | |
Name: | |
Email: | |
Subject: | |
Text: | |
Do you recommend this product to buy? | |
Add review |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.