AXC 3050 2700989 PHOENIX CONTACT Controller View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

AXC 3050 2700989 PHOENIX CONTACT Controller

AXC 3050

2700989

PHOENIX_CONTACT

Controller

More details


Control Systems (CST)

* Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX_CONTACT

* This article may be obsolete. Ask for a quotation and we will check if there are any units available. If not, one of our technicians will look for an alternative solution.

If our price is not the best, please ask us for a quote. Ask for a quotation

More info



Key Commercial Data

Orderkey2700989
Packing unit1 pc
Catalog pagePage 77 (C-6-2017)
GTIN4046356731201
Weight per Piece (excluding packing)444.000 g
Custom tariff number85371091
Country of originDE (Germany)

Note

Utilization restrictionEMC: class A product, see manufacturer's declaration in the download area

Dimensions

Width100 mm
Height125.9 mm
Depth74 mm

Ambient conditions

Degree of protectionIP20
Ambient temperature (operation)-25 °C ... 60 °C (up to 2000 m above sea level)
Ambient temperature (storage/transport)-40 °C ... 85 °C
Ambient temperature (assembly)-5 °C ... 60 °C
Permissible humidity (operation)5 % ... 95 % (according to DIN EN 61131-2)
Permissible humidity (storage/transport)5 % ... 95 % (according to DIN EN 61131-2)
Air pressure (operation)70 kPa ... 106 kPa (up to 3000 m above sea level)
Air pressure (storage/transport)58 kPa ... 106 kPa (up to 4500 m above mean sea level)
Shock30g, 11 ms period, half-sine shock pulse, according to IEC 60068-2-27
Vibration (operation)5g

Control system

Engineering toolPC WORX
Programming languages supportedProgramming in acc. with IEC 61131-3
Diagnostics toolDIAG+
Configuration toolConfig+ Version 1.01 or later

IEC 61131 runtime system

Engineering toolPC WORX
Program memory4 Mbyte
Mass storage8 Mbyte
Retentive mass storage128 kByte
Number of control tasks16
Realtime clockYes

Fieldbus function

Amount of process datamax. 4096 Bit (Axioline F local bus (input))
max. 4096 Bit (Axioline F local bus (output))
max. 8192 Bit (internal Modbus /TCP client)
Number of supported devicesmax. 63 (per station)
Number of local bus devices that can be connectedmax. 63 (observe current consumption)

Data interfaces

InterfaceAxioline F local bus
Number1
Connection methodBus base module
Transmission speed100 Mbps
InterfaceEthernet
Number3
Connection methodRJ45 socket
Transmission speed10/100 Mbps
InterfaceParameterization/operation/diagnostics
Number1
Connection methodMicro USB type B
Transmission speedmax. 115.2 kbps
InterfaceService
Number1
Connection methodUSB type A, socket

PROFINET

Device functionPROFINET controller, PROFINET device
SpecificationVersion 2.3
Update ratemax. of 256 devices

Direct I/Os

Input nameCounter input for 24 V signals
Number of inputsmax. 2 (via any digital inputs of the Axioline F modules)
Input frequencymax. 100 kHz (with AXL F DI16/1 HS 1H module)

Power supply

Typical current consumptiontyp. 408 mA (without I/Os and UL= 24 V)
Max. current consumptionmax. 976 mA (with 2 A at UBusfor the I/Os and UL= 24 V)
Supply voltage24 V DC
Supply voltage range19.2 V DC ... 30 V DC
Residual ripple± 5 %
Power dissipationmax. 9.8 W

Mechanical design

Weight444 g
Diagnostics displayNo
Controller redundancyNo
Safety functionNo

General data

ProcessorIntel®Atom™ E660 1x 1.3 GHz

Standards and Regulations

Electromagnetic compatibilityConformance with EMC Directive 2014/30/EU
Interference emissionNoise emission test according to EN 61000-6-3 Radio interference properties EN 55022 Class A
Immunity to surgeNoise immunity test in accordance with EN 61000-6-2 Transient overvoltage (surge) EN 61000-4-5/IEC 61000-4-5 Criterion B, DC supply lines: ±0.5 kV/±0.5 kV (symmetrical/asymmetrical), fieldbus cable shield: ±1 kV
Immunity to burstNoise immunity test in accordance with EN 61000-6-2 Fast transients (burst) EN 61000-4-4/IEC 61000-4-4 Criterion B, 2 kV
Immunity to EFNoise immunity test in accordance with EN 61000-6-2 Electromagnetic fields EN 61000-4-3/IEC 61000-4-3 Criterion A, Field intensity: 10 V/m
Immunity to ESDNoise immunity test in accordance with EN 61000-6-2 Electrostatic discharge (ESD) EN 61000-4-2/IEC 61000-4-2 Criterion B, 6 kV contact discharge, 8 kV air discharge
Immunity to conducted interferenceNoise immunity test in accordance with EN 61000-6-2 Conducted interference EN 61000-4-6/IEC 61000-4-6 Criterion A; Test voltage 10 V
Vibration (storage/transport)5g
Shock30g, 11 ms period, half-sine shock pulse, according to IEC 60068-2-27
Vibration (operation)5g
Shock (operation)10g (Bump endurance test according to DIN EN 60068-2-27)

Environmental Product Compliance

China RoHSEnvironmentally friendly use period: unlimited = EFUP-e
No hazardous substances above threshold values

Classifications

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.