PLC-INTERFACE for railway applications, consisting of basic terminal block with push-in connection and plug-in miniature relay with power contact, range: 0.7 x UN to 1.25 x UN, temperature class TX: -40°C to +70°C, 2 PDTs, input voltage 72 V DC

More details


Programmable Logic Controllers Plcs

INTERFACE Signal converters, switching devices, and power supply units - PHOENIX CONTACT

Solid state relays and power electronics. Relay - PHOENIX CONTACT

* Brand new produt in its original packing covered by the warranties and certifications provided by PHOENIX_CONTACT

QuantityPrice
10+33,28 €
20+32,97 €
*This price is per unit and is the net value (not including taxes if applicable).

Related products

More info



Dimensions

Width14 mm
Height80 mm
Depth94 mm

Ambient conditions

Ambient temperature (operation)-40 °C ... 70 °C (Temperature class TX)
Ambient temperature (storage/transport)-40 °C ... 85 °C

Coil side

Nominal input voltage UN72 V DC
Input voltage range in reference to UN0.7 ... 1.25
Typical input current at UN6 mA
Typical response time5 ms
Typical release time11 ms
Coil voltage48 V DC
Protective circuitBridge rectifier Bridge rectifier
Free-wheeling diode Damping diode
Surge protection
RCZ filter
Wide-range electronics
Operating voltage displayYellow LED
Power dissipation for nominal condition0.43 W

Contact side

Contact type2 PDT
Contact materialAgNi
Maximum switching voltage250 V AC/DC (Separating plate PLC-ATP must be installed for voltages larger than 250 V (L1, L2, L3) between identical terminal blocks in adjacent modules.)
Minimum switching voltage5 V (at 10 mA)
Min. switching current10 mA (At 5 V)
Maximum inrush current15 A (300 ms)
Limiting continuous current6 A
Interrupting rating (ohmic load) max.140 W (at 24 V DC)
85 W (at 48 V DC)
60 W (at 60 V DC)
44 W (at 110 V DC)
60 W (at 220 V DC)
1500 VA (for 250 V AC)
Switching capacity in acc. with DIN VDE 0660/IEC 609472 A (at 24 V, DC13)
0.2 A (at 250 V, DC13)
3 A (at 24 V, AC15)
3 A (at 120 V, AC15)
3 A (at 250 V, AC15)

General

Test voltage relay winding/relay contact5 kVrms (50 Hz, 1 min.)
Test voltage PDT/PDT2.5 kVrms (50 Hz, 1 min.)
Operating mode100% operating factor
Degree of protectionRelay socket
RT III (Relay)
Mechanical service lifeApprox. 3 x 107 cycles
Flammability rating according to UL 94V0
Standards/regulationsEN 50155 (VDE 0115 part 200)
EN 50178
IEC 62103
EN 61373
EN 50121
Rated surge voltage/insulation6 kV/Basic isolation
Rated insulation voltage250 V AC
Pollution degree2
Overvoltage categoryIII
Mounting positionany
Assembly instructionsIn rows with zero spacing

Connection data input side

Connection nameCoil side
Connection methodPush-in connection
Stripping length8 mm
Conductor cross section solid0.14 mm² ... 2.5 mm²
Conductor cross section flexible0.14 mm² ... 2.5 mm²