Product successfully added to your shopping cart
SF4B-H64CA-J05
PANASONIC
1
Safety Light Curtain Typ4 (PLe SIL3), Hand Protection, protective height 1303,4 mm, PNP/NPN, connector typ, IP65, muting function
Safety - PANASONIC > SF4B hand thru-beam safety sensors, Type 4 · Ple · SIL3 - PANASONIC
* Brand new product in its original packaging covered by the warranties and certifications provided by PANASONIC
Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
Product Number | SF4B-H64CA-J05 |
Part Number | SF4B-H64CA-J05 |
Product | Compact Safety Light Curtain[Type4 PLe SIL3] |
Details | Min. sensing object ø25 mm ø0.984 in (20 mm 0.787 in beam pitch) |
Product name | Compact Safety Light Curtain[Type4 PLe SIL3] SF4B-C |
Item | Specifications |
---|---|
Product Number | SF4B-H64CA-J05 |
Part Number | SF4B-H64CA-J05 |
No. of beam channels | 64 |
Protective height | 1,303.4 mm 51.315 in |
Current consumption:Large multipurpose indicator lights off | Emitter: 85 mA or less Receiver: 120 mA or less |
Current consumption:Large multipurpose indicator lights up | Emitter: 95 mA or less Receiver: 130 mA or less |
PFHD | 4.8 × 10-9 (Note) Probability of dangerous failure per hour. |
MTTFD | 100 years or more (Note) Mean time to dangerous failure. |
Net weight (Total of emitter and receiver) | approx. 1,400 g |
Applicable standards:International standard | IEC 61496-1 / 2 (Type 4), ISO 13849-1 (Category 4, PLe), IEC 61508-1 to 7 (SIL3) |
Applicable standards:Japan | JIS B 9704-1 / 2 (Type 4), JIS B 9705-1 (Category 4), JIS C 0508 (SIL3) |
Applicable standards:Europe (EU) | EN 61496-1 (Type 4), EN ISO 13849-1 (Category 4, PLe), EN 61508-1 to 7 (SIL3), EN 55011, EN 50178, EN 61000-6-2 (Note) Regarding EU Machinery Directive, a Notified Body, TÜV SÜD, has certified with the type examination certificate. |
Applicable standards:North America | ANSI / UL 61496-1 / 2 (Type 4), ANSI / UL 508, CAN / CSA 61496-1 / 2 (Type 4), CAN / CSA C22.2 No.14, OSHA 1910.212, OSHA 1910.217 (C), ANSI B11.1 to B11.19, ANSI / RIA 15.06 (Note) The product has been safety-certified in accordance with UL, ANSI, CSA, and other standards by TÜV SÜD America, a nationally recognizedsafety laboratory (NRTL) that has been approved by the Occupational Safety and Health Administration (OSHA) as defined by 29 CFR 1910.7 |
Applicable standards:South Korea (S-Mark) | S1-G-35-2005, S2-W-11-2003 |
Operating range | 0.3 to 7m0.984 to 22.966 ft (Note) The operating range is the possible setting distance between the emitter and the receiver. |
CE marking directive compliance | Machine Directive, EMC Directive, RoHS Directive |
Beam pitch | 20 mm0.787 in |
Min. sensing object | ø25 mm ø0.984 in opaque object (Note) In case the blanking function is valid, the operation mode is changed. |
Effective aperture angle | plus or minus 2.5℃ or less [for an operating range exceeding 3 m9.843 ft(conforming to IEC 61496-2 / ANSI/UL 61496-2) ] |
Power voltage | 24 V DC plus or minus 10 % Ripple P-P 10 % or less |
Control outputs (OSSD 1, OSSD 2) | PNP open-collector transistor / NPN open-collector transistor (switching method) • Maximum source current: 200 mA • Applied voltage: Same as supply voltage (between the control output and +V) • Residual voltage: 2.5 V or less (source current 200 mA, when using 20 m65.617 ftlength cable) • Leakage current: 0.1 mA or less (Including power supply OFF condition) • Maximum load capacity: 0.22 micro F (No load to maximum output current) • Load wiring resistance: 3Ωor less • Maximum sink current: 200 mA • Applied voltage: Same as supply voltage (between the control output and 0 V) • Residual voltage: 2.5 V or less (sink current 200 mA, when using 20 m65.617 ftlength cable) • Leakage current: 0.1 mA or less (Including power supply OFF condition) • Maximum load capacity: : 0.22 micro F (No load to maximum output current) • Load wiring resistance: 3Ωor less |
Control outputs (OSSD 1, OSSD 2):Operation mode | ON when all beam channels are received, OFF when one or more beam channels are interrupted (OFF also in case of any malfunction in the safety light curtain or the synchronization signal) (Note) During muting, control output will not turn off even if the beams are interrupted. (Note) When the blanking function is enabled, the operating mode will change. |
Control outputs(OSSD1, OSSD2):Protection circuit | Incorporated |
Response time | OFF response: 14 ms or less ON response: 80 to 90 ms |
Auxiliary output (Non-safety output) | PNP open-collector transistor / NPN open-collector transistor (switching method) • Maximum source current: 60 mA • Applied voltage: Same as supply voltage (between the auxiliary output and +V) • Residual voltage: 2.5 V or less (source current 60 mA, when using 20 m65.617 ftlength cable) • Maximum sink current: 60 mA • Applied voltage: Same as supply voltage (between the auxiliary output and 0 V) • Residual voltage: 2.5 V or less (sink current 60 mA, when using 20 m65.617 ftlength cable) |
Auxiliary output (Non-safety output):Operation mode | OFF when control outputs are ON, ON when control outputs are OFF (Factory setting, operating mode can be changed using the SFB-HC handy-controller.) |
Auxiliary output (Non-safety output):Protection circuit | Incorporated |
Muting auxiliary output | NPN open-collector transistor • Maximum sink current: 100 mA • Applied voltage: Same as supply voltage (between the muting auxiliary output and 0 V) • Residual voltage: 2.5 V or less (sink current 100 mA, when using 20 m65.617 ftlength cable) |
Muting auxiliary output:Operation mode | When muting auxiliary output: ON |
Muting auxiliary output:Protection circuit | Incorporated |
ELCA function | Incorporated (reducing mutual interference automatically) |
Emission halt function | Incorporated |
Interlock function | Incorporated [Manual reset / Auto reset] (Note) The manual reset and automatic reset are possible to be switched depending on the wiring status. |
External device monitoring function | Incorporated |
Override function | Incorporated |
Muting function | Incorporated |
Large multi-purpose indicator function | Incorporated |
Optional functions | Muting setting changing, override setting changing, fixed blanking, floating blanking, light emitting amount control, auxiliary output switching, protecting, interlock setting changing, external relay monitor setting changing (Note) In case of using optional function, the handy-controller SFB-HC is required. |
Pollution degree | 3 |
Operating altitude | 2,000 m6,561.68 ftor less (Note) Do not use or store in an environment pressurized to atmospheric pressure or higher at an altitude of 0 m. |
Environmental resistance:Degree of protection | IP65 (IEC) |
Ambient temperature | -10 to +55℃+14 to +131 ℉(No dew condensation or icing allowed), Storage: –25 to +60 ℃–3 to +140 ℉ |
Ambient humidity | 30 to 85 % RH, Storage: 30 to 85 % RH |
Ambient illuminance | Incandescent light: 3,500 liter x or less at the light-receiving face |
Environmental resistance:Dielectric strength voltage | 1,000 V AC for one min. between all supply terminals connected together and enclosure |
Insulation resistance | 20 MΩ or more, with 500 V DC megger between all supply terminals connected together and enclosure |
Vibration resistance | 10 to 55 Hz frequency, 0.75 mm0.030 inamplitude in X, Y and Z directions for two hours each |
Shock resistance | 300 m / s2acceleration (30 G approx.) in X, Y and Z directions for three times each |
Emitting element | Infrared LED (Peak emission wavelength: 850 nm0.033 mil) |
Material | Enclosure: Polycarbonate |
Cable | 0.15 mm2(power line: 0.2 mm2) 12-core heat-resistant PVC cable with connector, 0.5 m 1.640 ft long |
Cable extension | Extension up to total 50 m164.042 ftis possible for both emitter and receiver optional mating cables |
Accessories | SF4B-TR25 (Test rod): 1 pc. |
Title: | Size: | Type: |
---|---|---|
PDF CATALOG PANASONIC SENSORS EN.pdf | 31 Mbytes | |
PDF CATALOGUE PANASONIC EN.pdf | 15 Mbytes | |
Download general catalog |
No customer reviews for the moment.
Rating: | |
Name: | |
Email: | |
Subject: | |
Text: | |
Do you recommend this product to buy? | |
Add review |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.