DPC-L101-P PANASONIC Controller DPC-L101-P for serie DPH-L100, PNP, supply voltage 12-24VDC, output 1-5VDC o.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

DPC-L101-P PANASONIC Controller DPC-L101-P for serie DPH-L100, PNP, supply voltage 12-24VDC, output 1-5VDC o..

DPC-L101-P

PANASONIC

Controller DPC-L101-P for serie DPH-L100, PNP, supply voltage 12-24VDC, output 1-5VDC or 4-20mA, cable 2m, IP40

More details


Pressure sensors - PANASONIC > DPC fluid and air pressure sensor - PANASONIC

* Brand new product in its original packaging covered by the warranties and certifications provided by PANASONIC

* This article is restricted. Please ask us for a quotation and we will check if there are units available or we will offer you an alternative product.

If our price is not the best, please ask us for a quote. Ask for a quotation

Often bought together

More info



Product Number DPC-L101-P
Part Number DPC-L101-P
Product Head-separated Dual display Digital Pressure Sensor [For gas & liquid]
Details Controller
Product name Head-separated Dual display Digital Pressure Sensor [For gas & liquid] DPC-L100 / DPH-L100

Item Specifications
Product Number DPC-L101-P
Part Number DPC-L101-P
CE marking directive compliance EMC Directive, RoHS Directive
Rated pressure range DPH-L113V : -0.1 to +1 MPa
DPH-L113 : 0 to +1 MPa
DPH-L133 : 0 to +3.5 MPa
DPH-L114 : 0 to +10 MPa
DPH-L154 : 0 to +50 MPa
(Note) : Values differ depending on a connected sensor head.
Set pressure range [DPH-L113V]
-1.177 to +1.177 MPa
-12.00 to +12.00 kgf/cm2
-11.77 to +11.77 bar
-170.6 to +170.6 psi
[DPH-L113]
-1.070 to +1.070 MPa
-10.91 to +10.91 kgf/cm2
-10.70 to +10.70 bar
-155.2 to +155.2 psi
[DPH-L133]
-3.74 to +3.74 MPa
-38.1 to +38.1 kgf/cm2
-37.4 to +37.4 bar
-542 to +542 psi
[DPH-L114]
-10.70 to +10.70 MPa
-109.1 to +109.1 kgf/cm2
-107.0 to +107.0 bar
-1552 to +1552 psi
[DPH-L154]
-53.5 to +53.5 MPa
-545 to +545 kgf/cm2
-535 to +535 bar
-1980 to +7760 psi
(Note) : Values differ depending on a connected sensor head.
Set pressure resolution DPH-L113V : 0.001 MPa
DPH-L113 : 0.001 MPa
DPH-L133 : 0.01 MPa
DPH-L114 : 0.01 MPa
DPH-L154 : 0.1 MPa
(Note): Values differ depending on a connected sensor head.
Display 4 digits +4 digits 3-color LCD display
(Display refresh rate : 250 ms, 500 ms, 1,000 ms, selectable by key operation)
Display : Displayable pressure range [DPH-L113V]
-0.155 to +1.022 MPa
-1.58 to +10.42 kgf/cm2
-1.55 to +10.22 bar
-22.4 to +148.2 psi
[DPH-L113]
-0.050 to +1.020 MPa
-0.51 to +10.40 kgf/cm2
-0.50 to +10.20 bar
-7.2 to +148.0 psi
[DPH-L133]
-0.17 to +3.57 MPa
-1.7 to +36.4 kgf/cm2
-1.7 to +35.7 bar
-24 to +518 psi
[DPH-L114]
-0.50 to +10.20 MPa
-5.1 to +104.0 kgf/cm2
-5.0 to +102.0 bar
-72 to +1480 psi
[DPH-L154]
-2.5 to +51.0 MPa
-25 to +520 kgf/cm2
-25 to +510 bar
-360 to +7400 psi
(Note): Values differ depending on a connected sensor head.
Supply voltage 12 to 24 V DC ±10 % Ripple P-P 10 % or less
Power consumption Normal operation : 960 mW or less (Current consumption 40 mA or less at 24 V supply voltage)
ECO mode (STD) : 720 mW or less (Current consumption 30 mA or less at 24 V supply voltage)
ECO mode (FULL) : 600 mW or less (Current consumption 25 mA or less at 24 V supply voltage)
Excluding the current consumption of sensor head and analog output current
Comparative output
PNP open-collector transistor (2 outputs)
・ Maximum source current : 50 mA
・ Applied voltage : 30 V DC or less
(between comparative output and +V)
・ Residual voltage : 1 V or less (at 50 mA source current)
Comparative output:Output operation NO / NC, selectable by key operation
Comparative output:Output modes EASY mode / Hysteresis mode / Window comparator mode
Comparative output:Hysteresis Minimum 1 digit (variable)(however, 2 digits when using psi unit)
Comparative output:Repeatability Within ±0.2 % F.S.
Comparative output:Response time 5 ms, 10 ms, 25 ms, 50 ms, 100 ms, 250 ms, 500 ms, 1,000 ms, 5,000 ms, selectable by key operation
Comparative output:Short-circuit protection Incorporated
Analog output
・ Output current : 1 to 5 V DC
・ Zero point : within 1 V ±0.5 % F.S. (excluding DPH-L113V) within 1.364 V ±0.5 % F.S. (DPH-L113V)
・ Span : within 4 V ±0.5 % F.S.
・ Linearity : within ±0.1 % F.S.
・ Output impedance : 1 kΩ approx.


・ Output current : 4 to 20 mA
・ Zero point : within 4 mA ±1.0 % F.S. (excluding DPH-L113V) within 5.455 mA ±1.0 % F.S. (DPH-L113V)
・ Span : within 16 mA ±1.5 % F.S.
・ Linearity : within ±0.1 % F.S.
・ Load resistance : 250 Ω (max.)
Inputs : Sensor head input Input voltage range : 1 to 5 V DC (over rated pressure range)
Inputs : External input
ON voltage : 5 V to +V DC
OFF voltage : 0.6 V DC or less, or open
Input impedance : 10 kΩ approx.
Input time : 1 ms or more
Operation indicator Orange LED
(Comparative output 1 operation indicator, comparative output 2 operation indicator : Lights up when each comparative output is ON )
Protection IP40 (IEC)
Ambient temperature -10 to +50 ℃+14 to +122 ℉(No dew condensation or icing allowed), Storage : -10 to +60 ℃+14 to +140 ℉
Ambient humidity 35 to 85 % RH, Storage : 35 to 85 % RH
Voltage withstandability 500 V AC for one min. between all supply terminals connected together and enclosure
Insulation resistance 50 MΩ, or more, with 500 V DC megger between all supply terminals connected together and enclosure
Vibration resistance 10 to 500 Hz frequency, double amplitude 3 mm0.118 inor maximum acceleration 196 m/s2, in X, Y and Z directions for two hours each (when panel mounting bracket is mounted: 10 to 150 Hz frequency, double amplitude 0.75 mm0.030 inor maximum acceleration 49 m/s2, in X, Y and Z directions for two hours each)
Shock resistance 100 m/s2acceleration in X, Y and Z directions three times each
Temperature characteristics Within ±0.5 % F.S. (ambient temperature range based on +20 ℃+68 ℉)
Material Enclosure : PBT (glass fiber reinforced),
LCD display : Acrylic,
Mounting threaded part : Brass (nickel plated),
Switch part : Silicone rubber
Connecting method Connector
Cable length Total length up to 100 m328.084 ft(less than 30 m98.425 ftwhen conforming to CE marking) is possible with 0.3 mm2, or more, cable.
Weight Net weight : 25 g approx. (excluding connector attached cable),
Gross weight : 140 g approx.
Accessories CN-66A-C2 (Connector attached cable 2 m 6.562 ft), Pressure unit label: 1 set
Remark Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20 ℃+68 ℉.
The values specified above are applied only to the controller.

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.