J7KNU-05-01R 24 J7KN9813G 668196 OMRON Micro contactor, inverter with mechanical lock, 2.2kW, 3-pole (NO) + .. View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

J7KNU-05-01R 24 J7KN9813G 668196 OMRON Micro contactor, inverter with mechanical lock, 2.2kW, 3-pole (NO) + ..

J7KNU-05-01R 24

J7KN9813G

J7KNU0501R24

OMRON

Available Ship on today

Micro contactor, inverter with mechanical lock, 2.2 kW, 3-pole (NA) + 1 NC contacts aux. on both sides, 12A AC1, (up to 440 V), 24 VAC

Micro contactor, reversing interlocked pair, 5A/2.2kW + 1 NC auxiliary on both sides, 24 VAC

More details


Low Voltage Switchgear > J7KN Contactors

* Brand new product in its original packaging covered by the warranties and certifications provided by OMRON

Total price: $51.20
Unit price: $51.20

*This price is per unit and is the net value (not including taxes if applicable).

If our price is not the best, please ask us for a quote. Ask for a quotation

More info



  • AC and DC operated
  • Integrated auxiliary contact
  • Available as motor contactor and contactor relay
  • >3 mm contact clearance acc. to IEC 60335-1 for safety applications
  • Reversing contactor with mechanical interlock
  • Mirror contacts (NC) acc. to IEC 60947-4-1 for safety applications
  • J7KNU is designed to fit 15 mm DIN rails, but J75KN snap-on adapter make it suitable also for the standard 35 mm DIN rail

Specifications & ordering info

Ordering information

Micro motor contactors

AC operated

Type

Ratings

Rated current

Main Contacts

Built-in Aux. contacts1

Order code

AC2, AC3

AC1

NO

NC

NO

NC

Coil voltage2, VAC
replace___with:

380 V

400 V

415 V

kW

660 V

690 V

kW

440 V

A

3 pole, with screw terminals

2.2

12

3

1

J7KNU-05-10-_____

24

48

90

110

180

230

2.2

12

3

1

J7KNU-05-01-_____

24

48

90

110

180

230

4 pole, with screw terminals

2.2

12

4

J7KNU-05-40-_____

24

48

90

110

180

230

Reversing, mechanical interlocked

2.2

12

3 × 2

1 × 2

J7KNU-05-01R-_____

24

48

90

110

180

230

DC operated

Type

Ratings

Rated current

Main Contacts

Built-in Aux. contacts3

Order code

AC2, AC3

AC1

NO

NC

NO

NC

Coil voltage, VDC
replace___with:

380 V

400 V

415 V

kW

660 V

690 V

kW

440 V

A

3 pole, with screw terminals

2.2

12

3

1

J7KNU-05-10-____D

24

48

60

110

2.2

12

3

1

J7KNU-05-01-____D

24

48

60

110

4 pole, with screw terminals

2.2

12

4

J7KNU-05-40-____D

24

48

60

110

Reversing, mechanical interlocked

2.2

12

3 × 2

1 × 2

J7KNU-05-01R-____D

24

48

60

110

Micro contactor relays

AC operated

Ratings

Rated Current

Contacts

Distinc. number
acc. to DIN EN 50011

Order code

AC15

Ith

NO

NC

Coil voltage

230V

A

400V

A

A

4-pole, with screw terminals

3

1.5

5

4

40E

J7KNU-AR-40_____

24

48

90

110

180

230

3

1.5

5

2

2

22E

J7KNU-AR-22_____

24

48

90

110

180

230

DC operated

Ratings

Rated Current

Contacts

Distinc. number
acc. to DIN EN 50011

Order code

AC15

Ith

NO

NC

Coil voltage

230V

A

400V

A

A

4-pole, with screw terminals

3

1.5

5

4

40E

J7KNU-AR-40____D

24

48

60

110

3

1.5

5

2

2

22E

J7KNU-AR-22____D

24

48

60

110

Accessories

Snap-On adapter

Specification

Type

Order code

For snap-on mounting of J7KNU series on 35 mm DIN-rail acc. DIN EN 50022

P1039

J75KN-P1039

Specifications

Coil voltage

Suffix

Voltage marking at coil

Rated control voltage Us

for 50 Hz

for 60 Hz

range for 50 Hz

range for 60 Hz

V

V

min V

max V

min V

max V

24

24

24

22

24

24

24

48

48

48

48

50

48

52

90

100

100

90

100

100

105

110

110-115

120-125

110

115

120

125

180

200

200

185

200

200

210

230

220-230

230-250

220

230

230

250

Standard voltages in bold type letters. Coil not exchangeable.

Please see datasheet J7KN Motor Contactor for RC-suppressor units.

Standards

Approved Standards

Standard

Guide No (US, C)

UL listed

NLDX, NLDX7

EAC

***

Fulfilled Standards and directives

Standard

Directive

VDE0660

Low Voltage Directive 2006/95/EC

IEC 60947-5-1

EMC Directive 2004/108/EC

EN 60947-5-1...
Contactor relay

EN 60947-4-1...
Motor contactor

RoHS + WEEE 2002/95/EC + “002/96/EC


1.Contacts suitable for electronic circuits, according to EN947-5-4 for rated voltage 24 VDC (test ratings 17 VDC, 5 mA) positively guided contacts
2.For Detail Coil information, please seeRefer to Coil voltage
3.Contacts suitable for electronic circuits, according to EN947-5-4 for rated voltage 24 VDC (test ratings 17 VDC, 5 mA) positively guided contacts

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.