EJ1G-HFUA-NFLK 232143 OMRON Temperature Control Panel, EJ1 Gradient Mod. Coms without programming 232 Screw View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

EJ1G-HFUA-NFLK 232143 OMRON Temperature Control Panel, EJ1 Gradient Mod. Coms without programming 232 Screw

EJ1G-HFUA-NFLK

232143

OMRON

Available

Ship on today

Temperature Control Panel, EJ1 Gradient Mod. Coms without programming 232 Screw

More details


Temperature Sensors

EJ1

* Brand new product in its original packaging covered by the warranties and certifications provided by OMRON

*This price is per unit and is the net value (not including taxes if applicable).

Related products

More info



CelciuX° (EJ1)Advanced and Multi-Loop controllers
CelciuX° (EJ1) - Multi-Loop temperature control – Control and Connectivity
CelciuX° (EJ1) is designed to handle complex temperatureprofiles thanks to Omron’s unique Gradient temperatureControl (GTC) algorithm and to offer easy program-less communication with Omron and third-party PLCs andHMI. Aboveall,CelciuX° (EJ1)
incorporates all “simple to use” clever temperature control technology, like 2-PID, dis- turbance control and various ways of tuning.
• Interfaces to a wide range of industrial networks
• Reduced engineering due to Program-less communications, Smart Active Parts and
FunctionBlock Libraries
• Available with screw terminals and screw-less clamp terminals
• One unit handling various types of input, such as Pt, Thermocouple, mA, and V
input
• Gradient Temperature Control (GTC)
Ordering information
TypeControl pointsControl outputsAuxiliary outputs Other functions Terminal Order code
Basic unit22 voltage (pulse) 2 transistor (NPN) *1
2 CT input *2 + 2 event inputM3 screws EJ1N-TC2A-QNHB
Basic unit22 voltage (pulse) 2 transistor (NPN) *12 CT input *2 + 2 event inputScrew-less clamp EJ1N-TC2B-QNHB Basic unit22 current2 transistor (NPN) *12 event inputM3 screws EJ1N-TC2A-CNB Basic unit22 current2 transistor (NPN) *12 event inputScrew-less clamp EJ1N-TC2B-CNB
Basic unit44 voltage (pulse) ––M3 screws EJ1N-TC4A-QQ Basic unit44 voltage (pulse) ––Screw-less clamp EJ1N-TC4B-QQ High function unit––4 transistor(NPN)4 event inputM3 screws EJ1N-HFUA-NFLK High function unit––4 transistor(NPN)4 event inputScrew-less clamp EJ1N-HFUB-NFLK
DeviceNet unit ––––Screw connectorEJ1N-HFUB-DRT
Ethernet unit*3
End unit *4
––––3 x RJ45EJ1N-HFU-ETN
––2 transistor(NPN)–M3 screws EJ1C-EDUA-NFLK
End unit *4 ––2 transistor(NPN)–Removable ConnectorEJ1C-EDUC-NFLK
*1For heating/cooling control applications, the auxiliary outputs on the 2-point models are used for cooling control.
On the 4-point models, heating/cooling control can be performed for two input points only.
*2When using the heater burnout alarm, purchase a Current Transformer (E54-CT1 or E54-CT3) separately.
*3This unit mounts to the left of the CelciuX° (EJ1) configuration and enables PROFINET or Modbus/TCP network connection. Combine the HFU-ETN with an EDU_-NFLK end unit to use with other devices supporting Modbus-RTU like E5_N temperature controllers and MX2 Inverters.
*4An End unit is always required for connection to a Basic unit or an HFU. An HFU cannot operate without a Basic unit.
TypeControl pointsControl outputsAuxiliary outputs Other functions Terminal Order code
Basic unit 2 (GTC) 2 voltage (pulse)*1 2 transistor(NPN)2 CT input*2
M3 screws EJ1G-TC2A-QNH
Basic unit 2 (GTC) 2 voltage (pulse)*1 2 transistor(NPN)2 CT input*2 Screw-less clampEJ1G-TC2B-QNH Basic unit 4 (GTC) 4 voltage (pulse)*1 ––M3 screws EJ1G-TC4A-QQ Basic unit 4 (GTC) 4 voltage (pulse)*1 ––Screw-less clampEJ1G-TC4B-QQ
High function unit– (GTC) –4 transistor(NPN)–M3 screws EJ1G-HFUA-NFLK
High function unit– (GTC) –4 transistor(NPN)–Screw-less clamp EJ1G-HFUB-NFLK
End unit*3
––2 transistor(NPN)–M3 screws EJ1C-EDUA-NFLK
End unit*3 ––2 transistor(NPN)–Removable ConnectorEJ1C-EDUC-NFLK
*1Heating/cooling control is not supported for gradient temperature control.
*2When using the heater burnout alarm, use a Current Transformer (E54-CT1 or E54-CT3) (sold separately).
*3An End-unit (EDU) is always required to connect an HFU and or a Basic TC unit for Communications and Power supply.
A GTC (Gradient Temperature Control) basic TC unit always requires a GTC HFU unit.
Accessories
Current transformer
Diameter Order code
5.8 dia.E54-CT1
12.0 dia.E54-CT3
Communications and cables
Description Order code
G3ZA connecting cable 5 meterEJ1C-CBLA050
USB programming cable E58-CIFQ1
PC based configuration and tuning softwareCX-Thermo EST2-2C-MV4
PROFIBUS Gateway PRT1-SCU11
533
CelciuX° (EJ1)Advanced and Multi-Loop controllers
Specifications
Item TypeEJ1_-TC2EJ1_-TC4
Power supply voltage 24 VDC
Operating voltage range85% to 110% of rated voltage
Power consumption 4 W max. (at maximum load)5 W max. (at maximum load)
Input (see note)*1
Thermocouple: K, J, T, E, L, U, N, R, S, B, W, PLII
ES1B Infrared Thermosensor: 10 to 70°C, 60 to 120°C, 115 to 165°C, 140 to 260°C. Analog input: 4 to 20 mA, 0 to 20 mA, 1 to 5 V, 0 to 5 V, 0 to 10 V
Platinum resistance thermometer: Pt100, JPt100
Input impedanceCurrent input: 150max., voltage input: 1 M min.
Control outputsVoltage output Output voltage: 12 VDC ±15%, max. load current:21 mA (PNP models with short-circuit protection circuit)
Transistor output Max. operating voltage: 30 V, max. load current: 100 mA–
Current output Current output range: 4 to 20 mA or 0 to 20 mA DC – Load: 500  max. (including transfer output)
(Resolution: Approx: 2,800 for 4 to 20 mA DC, approx. 3,500 for 0 to 20 mA DC)
Event inputs Input points 2 –
Contact input ON: 1 k max.,OFF. 100 k min.–
Non-contact input ON: Residual voltage: 1.5 V max., – OFF: Leakage current: 0.1 mA max.
Outflow current: approx. 4 mA per point –
Number of input and control points Input points: 2, control points: 2Input points: 4, control points: 4
Setting method Via communications
Control methodON/OFF control or 2-PID (with autotuning, selftuning, Heat & Cool autotuning and non-linear cool output selection)
Other functionsTwo-point input shift, digital input filter, remote SP, SP ramp, manual manipulatedvariable, manipulated variable limiter, interference overshoot ad- justment, loop burnout alarm, RUN/STOP, banks, I/O allocations, etc.
Alarm output2 points via End unit
Communication RS-485, PROFIBUS, Modbus, DeviceNetRS-485, PROFIBUS, Modbus, DeviceNet
Size in mm (W×H×D)31×96×109
Weight 180 g
Ambient temperature rangeOperating–10°C to 55°C, Storage –25°C to 65°C (with no icing or condensation)
Ambient humidity rangeOperating 25% to 85% (with no condensation)
*1Inputs are fully multi-input. Therefore, platinum resistance thermometer, thermocouple, infrared thermosensor, and analog input can be selected.
Dimensions
ItemSize in mm (H×W×D) EJ1N-HFU_-NFL_95.4×31.0×104.9/109.0
EJ1N-HFUB-DRT 90.9×31.0×82.2
EJ1C-EDU 95.4×15.7×76.2/79.7
534

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

Latest Customer Reviews

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.