CS1W-MAD44 135688 OMRON Control System, 4/4 Module E / S Analog View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

CS1W-MAD44 135688 OMRON Control System, 4/4 Module E / S Analog

CS1W-MAD44

135688

OMRON

Available

Ship on today

Control System, 4/4 Module E / S Analog

More details


Programmable Logic Controllers Plcs

CS1

* Brand new product in its original packaging covered by the warranties and certifications provided by OMRON

*This price is per unit and is the net value (not including taxes if applicable).

Related products

More info



CS-Series analog and process I/O units Rack PLC
From basic analog I/O to process control
CS1 offers a wide choice of analog input units, fit for any application, from low-speed, multi-channel temperature measurement to high-speed, high-accuracy data acquisi- tion. Analog outputs can be used for accurate control or external indication.
Advanced units with built-in scaling, filtering and alarm functions reduce the need for complex PLC programming. High-accuracy process I/O units support an extensive
range of sensors, for fast and accurate data acquisition. All process and temperature
I/O units provide isolation between all individual channels.
Ordering information
Points Type Ranges Resolution Accuracy*1 Conversion time
Remarks Connection type
Order code
4 Analog input 0 to 5 V,
1/8,000 V: 0.2% of PV
250 μs/point Offset/gain adjustment, peak hold,
M3 CS1W-AD041-V1
8 Analog input
0 to 10 V,
–10 to 10 V,
I: 0.4% of PV
moving average, alarms
M3 CS1W-AD081-V1
16 Analog input
1 to 5 V,
4 to 20 mA
0.2% of PV 2 × MIL (34p.) CS1W-AD161
4 Analog output 0 to 5 V,
0 to 10 V,
–10 to 10 V,
1 to 5 V,
4 to 20 mA
1/4,000 V: 0.3% of PV I: 0.5% of PV
1 ms/point Offset/gain adjustment M3 CS1W-DA041
8 Voltage output 0 to 5 V,
0 to 10 V,
–10 to 10 V,
1 to 5 V
0.3% of PV Offset/gain adjustment, output hold M3 CS1W-DA08V
8 Current output 4 to 20 mA 0.5% of PV M3 CS1W-DA08C
4 + 4 Analog in + output 0 to 5 V,
0 to 10 V,
–10 to 10 V,
1 to 5 V
(4 to 20 mA input)
1/8,000 V in: 0.2% of PV I in: 0.4% of PV out: 0.3% of PV
1 ms/point Offset/gain adjustment, scaling, peak hold, moving average, alarms, output hold
M3 CS1W-MAD44
4 Process input 4 to 20 mA,
0 to 20 mA,
0 to 10 V,
–10 to 10 V,
0 to 5 V,
–5 to 5 V,
1 to 5 V,
1 to 1.25 V,
–1.25 to 1.25 V
1/64,000 0.05% of PV 5 ms/point Configurable alarms, maintenance functions, user-defined scaling, zero/ span adjustment, square root, totalis- er.
M3 CS1W-PDC11
8 Process input –10 to 10 V,
0 to 5 V,
1 to 5 V,
4 to 20 mA
1/16,000 0.3% of PV 62.5 ms/point Configurable alarms, zero/span adjust- M3 CS1W-PDC55 ment, square root
4 Thermocouple input B, E, J, K, L, N, R, S, T, U, WRe5-26, PLII,
–100 to 100 mV
1/64,000 0.05% of PV 5 ms/point Configurable alarms (absolute + rate-of-change), peak hold, maintenance functions
M3 CS1W-PTS11
4 Resistance thermometer in- put
Pt50, Pt100 JPt100, Ni508.4
1/64,000 0.05% of PV 5 ms/point Configurable alarms (absolute + rate-of-change), peak hold, maintenance functions
M3 CS1W-PTS12
4 Thermocouple input B, J, K, L, R, S, T 0.1°C 0.3% of PV 62.5 ms/point 4 configurable alarm outputs M3 CS1W-PTS51
4 Resistance thermometer in- put
Pt100, JPt100 0.1°C 0.3% of PV 62.5 ms/point 4 configurable alarm outputs M3 CS1W-PTS52
8 Thermocouple input B, J, K, L, R,S, T 0.1°C 0.3% of PV 31.2 ms/point Configurable alarms per channel M3 CS1W-PTS55
8 Resistance thermometer in- put
Pt100, JPt100 0.1°C 0.3% of PV 31.2 ms/point Configurable alarms per channel M3 CS1W-PTS56
4 2-Wire transmitter input 1 to 5 V,
4 to 20 mA
8 Power transducer input –1 to 1 mA,
0 to 1 mA
8 Power transducer input –100 to 100 mV,
0 to 100 mV
1/4,096 0.2% of FS 25 ms/point Built-in power supply for transmitter, configurable alarms, square root,
rate-of-change, etc.
1/4,096 0.2% of FS 25 ms/point Inrush current limiter, configurable alarms, averaging, etc.
1/4,096 0.2% of FS 25 ms/point Inrush current limiter, configurable alarms, averaging, etc.
M3 CS1W-PTW01
M3 CS1W-PTR01
M3 CS1W-PTR02
4 Pulse rate input 20000 pps, voltage,
up to
– 25 ms/point Averaging, totaliser M3 CS1W-PPS01
open collector, contact 1/32,000
40
CS-Series analog and process I/O units Rack PLC
Points Type Ranges Resolution Accuracy*1 Conversion time
Remarks Connection type
Order code
4 Isolated control output 1 to 5 V,
4 to 20 mA
1/4,000 I: 0.1% of FS V: 0.2% of FS
25 ms/point Output readback, high/low/rate limit- M3 CS1W-PMV01 ing, disconnection alarm, zero/span
adjustment
4 Isolated control output –10 to 10 V,
0 to 10 V,
–5 to 5 V,
0 to 5 V,
–1 to 1 V,
0 to 1 V
1/4,000 0.1% of FS 10 ms/point High/low/rate limiting, output hold, zero/span adjustment
M3 CS1W-PMV02
*1 Accuracy for Voltage and Current Inputs/Outputs as percentage of full scale and typical value at 25°C ambient temperature (Consult the operation manual for details) Accuracy for Temperature Inputs/Outputs as percentage of process value and typical value at 25°C ambient temperature (Consult the operation manual for details)
Note: All analog I/O units are designated as special I/O units
41

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

Latest Customer Reviews

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.