Surge arrester, 4-pole with fuse monitoring 280 V. Surge arrester, type 2, ready for connection with remote signalling and voltage monitoring • Complete unit consisting of upper part and base, pre-mounted and ready for connection• Suitable for TN network systems• With voltage monitoring of phases and function monitoring of arrester upper parts • With remote signalling and potential-free changeover contact• Plug-in upper part; upper part can be separated from base without tools• Incl. thermal and dynamic cut-off unit• With visual display of defects• High current conductivity and long service life* Complete = cover and base
TBS Transient and lightning protection systems - OBO BETTERMANN
Brand new product in its original packaging covered by the warranties and certifications provided by OBO BETTERMANN
Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
| Arrester surge current (8/20 µs) [total] | 80 kA |
|---|---|
| Blow-out | no |
| CO2 Footprint (GWP) Cradle-to-Gate | 2,4386 kg CO2e / 1 Piece |
| Conductor cross-section, rigid (single-wire/multiwire), max. | 35 mm² |
| Conductor cross-section, rigid (single-wire/multiwire), min. | 2,5 mm² |
| Dimension | 280V |
| Installation type | DIN rail 35 mm |
| Integrated back-up fuse | no |
| Lightning protection zone LPZ | 1→2 |
| Max. mains-side overcurrent protection | 125 |
| Maximum back-up fuse | 125 A |
| Maximum continuous voltage AC | 280 V |
| Maximum discharge current (8/20 μs) | 40 kA |
| Network form | TN |
| Nominal discharge current (8/20 µs) | 20 kA |
| Nominal discharge current (8/20 µs) [L-N] | 20 kA |
| Nominal voltage AC (50/60 Hz) | 230 V |
| Operating temperature, max. | 80 °C |
|---|---|
| Operating temperature, min. | -40 °C |
| Permitted temperature range, max. | 80 °C |
| Permitted temperature range, min. | -40 °C |
| Pole version | 4 |
| Protection rating | IP20 |
| Remote signalling | no |
| Response time | <25 ns |
| Signalling on device | Visual |
| SPD to EN 61643-11 | Type 2 |
| SPD to IEC 61643-1 | Class II |
| Test class, type 2 | yes |
| TN network form | yes |
| TN-C-S network form | yes |
| TN-S network form | yes |
| Version for | 4-pole with FS-SÜ; 280 V |
| Title: | Size: | Type: |
|---|---|---|
| PDF CATALOGUE SURGE PROTECTION OBO EN.pdf | 24 Mbytes |
|
No customer reviews for the moment.
| Rating: |
|
| Name: | |
| Email: | |
| Subject: | |
| Text: | |
| Do you recommend this product to buy? | |
|
|
|
| Add review | |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.