ANUNCIAR
V-PV-T2-1500+FS 5094212 OBO BETTERMANN DOWNLOADER SOBRET. V-PV View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

V-PV-T2-1500+FS 5094212 OBO BETTERMANN DOWNLOADER SOBRET. V-PV

V-PV-T2-1500+FS

5094212

OBO BETTERMANN

DOWNLOADER SOBRET. V-PV

Downloader sobret. V-PV Conex. And photovoltaic + remote 1500V DC grey

PV complete block 1,500 V DC with remote signalling. Type 2 surge protection for PV plants.• Surge protection according to IEC 60364-7-712 (VDE 0100-712)• Arresting capacity of 20 kA per pole and up to 40 kA (8/20)• Error-resistant Y circuit with status display• The FS variant possesses a potential-free changeover contact for remote signallingApplication: Surge protective devices for PV systems.

More details


Earthing, lightning and surge protection > Combined arrester for power supply systems

TBS Transient and lightning protection systems - OBO BETTERMANN

Brand new product in its original packaging covered by the warranties and certifications provided by OBO BETTERMANN

Total: $216.82
Unit price: $216.82
This price is per unit and is the net value (not including taxes if applicable).

If our price is not the best, please ask us for a quote. Ask for a quotation

Related products

Best sellers

More info



Arrester surge current (8/20 µs) [total]40 kA
Blow-outno
CO2 Footprint (GWP) Cradle-to-Gate0,1024 kg CO2e / 1 Piece
ColourGrey
Conductor cross-section, flexible (fine-wire), max.35 mm²
Conductor cross-section, flexible (fine-wire), min.2,5 mm²
Conductor cross-section, rigid (single-wire/multiwire), max.35 mm²
Conductor cross-section, rigid (single-wire/multiwire), min.2,5 mm²
DC network formyes
Dimension1500V DC
Explosion-tested versionno
FM contactsChangeover
Height120 mm
Installation typeDIN rail 35 mm
Integrated back-up fuseno
IT network formno
Length65,5 mm
Lightning protection zone LPZ1→2
Max. PV voltage1500 V
Maximum continuous voltage DC1500 V
Maximum discharge current (8/20 μs)40 kA
Network formDC
Nominal discharge current (8/20 µs)20 kA
OBO_Nominal load current (input/output terminal)50 A
Operating temperature, max.80 °C
Operating temperature, min.-40 °C
Other network formno
Permitted temperature range, max.80 °C
Permitted temperature range, min.-40 °C
Pole versionOther
Protection ratingIP20
Remote signallingyes
Response time<25 ns
Signalling on deviceVisual
SPD to EN 61643-11Type 2
SPD to IEC 61643-1Class II
Test class, type 1no
Test class, type 2yes
Test class, type 3no
TN network formno
TN-C network formno
TN-C-S network formno
TN-S network formno
TT network formno
Version forY configuration + RS
Width71,2 mm

ETIM for 5094212 Earthing, lightning and surge protection (EC001457)
Feature Name Feature Value
System configuration DC (EF009926) Yes
System configuration IT (EF009927) No
System configuration TN (EF009928) No
System configuration TN-C (EF009929) No
System configuration TN-C-S (EF009933) No
System configuration TN-S (EF009930) No
System configuration TT (EF009931) No
System configuration other (EF009932) No
Max. continuous voltage DC (EF004777) 1500 V
Voltage protection level (EF003525) 4.5 kV
Mounting method (EF000003) DIN rail (top hat rail) 35 mm
Construction size (EF002566) 4 modular spacing
Max. conductor cross section solid (solid, stranded) (EF008827) 35 mm²
Max. conductor cross section flexible (fine-strand) (EF008828) 35 mm²
Signalling at the device (EF004241) Optic
Integrated backup fuse (EF008797) No
Degree of protection (IP) (EF005474) IP20

Datasheet - PDF

Title: Size: Type:
PDF CATALOGUE SURGE PROTECTION OBO EN.pdf 24 Mbytes

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.