Product successfully added to your shopping cart
V50-B+C 3PHFS600
5093625
OBO BETTERMANN
1
CombiController V50 three-pole for PV systems + FS, 600V DC,
PV combination arrester V50, 600 V DC with remote signalling. V50 combination arrester, type 1+2, for PV systems with FS contact as potential-free changeover• Complete unit, consisting of plug-in varistor arrester with cut-off unit• Error-resistant Y circuit for use according to VDE 0100-712 (EN 50539-12)• Surge protection equipotential bonding to VDE 0100-443 (IEC 60364-4-44)• Arresting capacity to 12.5 kA (10/350) and 50 kA (8/20) per pole• Low DC voltage protection level: < 2.6 kV and Voc max. = 600 V DC• With visual display for use in distributor housingsApplication: PV systems with lightning protection system
Earthing, lightning and surge protection > Combined arrester for power supply systems
TBS Transient and lightning protection systems - OBO BETTERMANN > Surge protection, photovoltaics - OBO BETTERMANN
Brand new product in its original packaging covered by the warranties and certifications provided by OBO BETTERMANN
Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
| Blow-out | no |
|---|---|
| CO2 Footprint (GWP) Cradle-to-Gate | 1,0117 kg CO2e / 1 Piece |
| Conductor cross-section, rigid (single-wire/multiwire), max. | 35 mm² |
| Conductor cross-section, rigid (single-wire/multiwire), min. | 2,5 mm² |
| DC network form | yes |
| Dimension | 600V DC |
| FM contacts | Changeover |
| Installation type | DIN rail 35 mm |
| IT network form | no |
| Lightning protection zone LPZ | 0→2 |
| Lightning surge current (10/350 μs) | 12,5 kA |
| Max. mains-side overcurrent protection | 125 |
| Maximum back-up fuse | 125 A |
| Maximum continuous voltage DC | 600 V |
| Maximum discharge current (8/20 μs) | 50 kA |
| Network form | DC |
| Nominal discharge current (8/20 µs) | 30 kA |
| Nominal discharge current (8/20 µs) [L-N] | 30 kA |
| Operating temperature, max. | 80 °C |
|---|---|
| Operating temperature, min. | -40 °C |
| Other network form | no |
| Permitted temperature range, max. | 80 °C |
| Permitted temperature range, min. | -40 °C |
| Pole version | 3 |
| Protection rating | IP20 |
| Remote signalling | yes |
| Response time | <25 ns |
| Signalling on device | Visual |
| SPD to EN 61643-11 | Type 1+2 |
| SPD to IEC 61643-1 | Class I+II |
| TN network form | no |
| TN-C network form | no |
| TN-C-S network form | no |
| TN-S network form | no |
| TT network form | no |
| Version for | 3-pole for PV systems with FS |
| Title: | Size: | Type: |
|---|---|---|
| PDF CATALOGUE SURGE PROTECTION OBO EN.pdf | 24 Mbytes |
|
| V50-B+C 3PHFS600 5093625 OBO BETTERMANN CombiController V50 three-pole for PV systems + FS, 600V DC, | 63 Kbytes |
![]() |
No customer reviews for the moment.
| Rating: |
|
| Name: | |
| Email: | |
| Subject: | |
| Text: | |
| Do you recommend this product to buy? | |
|
|
|
| Add review | |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.