V20-C 2-PH-1000 5094617 OBO BETTERMANN SurgeController V20 two-pole for photovoltaics, 1000V,

V20-C 2-PH-1000

5094617

OBO BETTERMANN

SurgeController V20 two-pole for photovoltaics, 1000V,

PV surge protection V20 2pole 1000 V DC. V20 surge arrester, Type 2, for earthed photovoltaic systems• Complete unit consisting of varistor arrester with cut-off unit• For PV systems directly earthed on DC side to VDE 0100-712 (EN 50539-12)• Surge protection equipotential bonding to VDE 0100-443 (IEC 60364-4-44)• V20-C 3-PH-1000 tested to EN 50539-11 (VDE / KEMA)• Arresting capacity to 40 kA (8/20) per pole• Low DC voltage protection level: < 4.0 kV and Voc max = 1,000 V DC• With visual function display for use in distributor housings Application: Directly earthed PV systems with or without isolated lightning protection system

More details


Earthing, lightning and surge protection > Surge protection device for power supply systems

TBS Transient and lightning protection systems - OBO BETTERMANN > Surge protection, photovoltaics - OBO BETTERMANN

Brand new product in its original packaging covered by the warranties and certifications provided by OBO BETTERMANN

* This article may be obsolete. Ask for a quotation and we will check if there are any units available. If not, one of our technicians will look for an alternative solution.

If our price is not the best, please ask us for a quote. Ask for a quotation

Related products

Best sellers

More info



Blow-outno
CO2 Footprint (GWP) Cradle-to-Gate0,8821 kg CO2e / 1 Piece
Conductor cross-section, rigid (single-wire/multiwire), max.35 mm²
Conductor cross-section, rigid (single-wire/multiwire), min.2,5 mm²
DC network formyes
Dimension1000V DC
Installation typeDIN rail 35 mm
Lightning protection zone LPZ1→2
Max. mains-side overcurrent protection125
Maximum back-up fuse125 A
Maximum continuous voltage DC1000 V
Maximum discharge current (8/20 μs)40 kA
Network formOther
Nominal discharge current (8/20 µs)20 kA
Operating temperature, max.80 °C
Operating temperature, min.-40 °C
Permitted temperature range, max.80 °C
Permitted temperature range, min.-40 °C
Pole version2
Protection ratingIP20
Remote signallingno
Response time<25 ns
Signalling on deviceVisual
SPD to EN 61643-11Type 2
SPD to IEC 61643-1Class II
Test class, type 2yes
Version for2-pole for earthed PV systems

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.