HLG-80H-C350D MEANWELL AC-DC Single output LED driver Constant current (CC) with built-in PFC, Output 0.35A .. View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

HLG-80H-C350D MEANWELL AC-DC Single output LED driver Constant current (CC) with built-in PFC, Output 0.35A ..

HLG-80H-C350D

MEANWELL

Available Ship on today

AC-DC Single output LED driver Constant current (CC) with built-in PFC, Output 0.35A / 257VDC, IP67, Timer dimming function

More details


LED DRIVERS > HLG

* Brand new product in its original packaging covered by the warranties and certifications provided by MEANWELL

* This article may be obsolete. Ask for a quotation and we will check if there are any units available. If not, one of our technicians will look for an alternative solution.

If our price is not the best, please ask us for a quote. Ask for a quotation

More info



90W Single Output LED Power SupplyHLG-80H-Cseries 90W Single Output LED Power SupplyHLG-80H-Cseries
90W Single Output LED Power SupplyHLG-80H-Cseries F110 F110
F110 Features : Features :
Features : Constant currentdesign Constant currentdesign
Constant currentdesign Universal AC input / Full range (up to 305VAC) Universal AC input / Full range (up to 305VAC)
Universal AC input / Full range (up to 305VAC) Built-in active PFC function Built-in active PFC function
Built-in active PFC function High efficiency up to 91.5% High efficiency up to 91.5%
High efficiency up to 91.5% Protections: Short circuit / Over voltage/ Over temperature Protections: Short circuit / Over voltage/ Over temperature
Protections: Short circuit / Over voltage/ Over temperature Cooling by free air convection Cooling by free air convection
Cooling by free air convection Output currentadjustable throughoutput cableor internal potentiometer Output currentadjustable throughoutput cableor internal potentiometer
Output currentadjustable throughoutput cableor internal potentiometer IP67 / IP65 design for indoor or outdoorinstallations IP67 / IP65 design for indoor or outdoorinstallations
IP67 / IP65 design for indoor or outdoorinstallations Three in one dimming function (1=10Vdcor 10V PWM signal or resistance) Three in one dimming function (1=10Vdcor 10V PWM signal or resistance)
Three in one dimming function (1=10Vdcor 10V PWM signal or resistance) Suitable for dry / damp/ wet locations Suitable for dry / damp/ wet locations
Suitable for dry / damp/ wet locations 7 years warranty (Note.5) 7 years warranty (Note.5)
7 years warranty (Note.5)MM IP65 IP67 MM IP65 IP67
MM IP65 IP67HLG-80H-C350 A HLG-80H-C350 A
HLG-80H-C350 A A : IP65 rated.Constant currentlevel can be adjusted throughinternal potentiometer. A : IP65 rated.Constant currentlevel can be adjusted throughinternal potentiometer.
A : IP65 rated.Constant currentlevel can be adjusted throughinternal potentiometer. B : IP67 rated. Constantcurrent level adjustablethrough output cable with 1=10Vdc or 10V PWM signal or resistance. D (option) : IP67 rated. Timer dimming function, contact MEAN WELL for details. B : IP67 rated. Constantcurrent level adjustablethrough output cable with 1=10Vdc or 10V PWM signal or resistance. D (option) : IP67 rated. Timer dimming function, contact MEAN WELL for details.
B : IP67 rated. Constantcurrent level adjustablethrough output cable with 1=10Vdc or 10V PWM signal or resistance. D (option) : IP67 rated. Timer dimming function, contact MEAN WELL for details.SPECIFICATION SPECIFICATION
SPECIFICATION MODEL MODEL
MODEL HLG-80H-C350 HLG-80H-C700 HLG-80H-C350 HLG-80H-C700
HLG-80H-C350 HLG-80H-C700 RATED CURRENT RATED CURRENT
RATED CURRENT 350mA 350mA
350mA 700mA 700mA
700mA CURRENT ACCURACY5.0% CURRENT ACCURACY5.0%
CURRENT ACCURACY5.0% CONSTANT CURRENT REGION Note.6 A type : 128V ~ 257VB type : 167V ~ 257V CONSTANT CURRENT REGION Note.6 A type : 128V ~ 257VB type : 167V ~ 257V
CONSTANT CURRENT REGION Note.6 A type : 128V ~ 257VB type : 167V ~ 257VA type : 64V ~ 129V B type : 84V ~ 129V A type : 64V ~ 129V B type : 84V ~ 129V
A type : 64V ~ 129V B type : 84V ~ 129V RATED POWER RIPPLE CURRENT RATED POWER RIPPLE CURRENT
RATED POWER RIPPLE CURRENT 89.95W 89.95W
89.95W 5% 5%
5% 90.3W 90.3W
90.3W OUTPUT OUTPUT
OUTPUT RIPPLE & NOISE 1Vp-p0.5Vp-p RIPPLE & NOISE 1Vp-p0.5Vp-p
RIPPLE & NOISE 1Vp-p0.5Vp-p Can be adjusted by internal potentiometer A type only Can be adjusted by internal potentiometer A type only
Can be adjusted by internal potentiometer A type only CURRENT ADJ. RANGE CURRENT ADJ. RANGE
CURRENT ADJ. RANGE 210 ~ 350mA420 ~ 700mA 210 ~ 350mA420 ~ 700mA
210 ~ 350mA420 ~ 700mA LINE REGULATION1% LINE REGULATION1%
LINE REGULATION1% 1% 1%
1% SETUP, RISE TIME HOLD UP TIME (Typ.) SETUP, RISE TIME HOLD UP TIME (Typ.)
SETUP, RISE TIME HOLD UP TIME (Typ.) 500ms, 80ms at full load230VAC /115VAC 500ms, 80ms at full load230VAC /115VAC
500ms, 80ms at full load230VAC /115VAC 16ms at full load 230VAC / 115VAC 16ms at full load 230VAC / 115VAC
16ms at full load 230VAC / 115VAC VOLTAGE RANGE Note.2 90 ~ 305VAC127VDC ~ 431VDC VOLTAGE RANGE Note.2 90 ~ 305VAC127VDC ~ 431VDC
VOLTAGE RANGE Note.2 90 ~ 305VAC127VDC ~ 431VDCINPUT INPUT
INPUT FREQUENCY RANGE POWER FACTOR (Typ.) FREQUENCY RANGE POWER FACTOR (Typ.)
FREQUENCY RANGE POWER FACTOR (Typ.) TOTAL HARMONIC DISTORTION TOTAL HARMONIC DISTORTION
TOTAL HARMONIC DISTORTION 47 ~ 63Hz 47 ~ 63Hz
47 ~ 63Hz PF>0.98/115VAC, PF>0.96/230VAC, PF>0.94/277VAC at full load (Please refer to "Power Factor Characteristic" curve) THD< 20% when output loading60% at 115VAC/230VAC input and output loading75% at 277VAC input PF>0.98/115VAC, PF>0.96/230VAC, PF>0.94/277VAC at full load (Please refer to "Power Factor Characteristic" curve) THD< 20% when output loading60% at 115VAC/230VAC input and output loading75% at 277VAC input
PF>0.98/115VAC, PF>0.96/230VAC, PF>0.94/277VAC at full load (Please refer to "Power Factor Characteristic" curve) THD< 20% when output loading60% at 115VAC/230VAC input and output loading75% at 277VAC input EFFICIENCY (Typ.) EFFICIENCY (Typ.)
EFFICIENCY (Typ.) AC CURRENT (Typ.) INRUSH CURRENT (Typ.) AC CURRENT (Typ.) INRUSH CURRENT (Typ.)
AC CURRENT (Typ.) INRUSH CURRENT (Typ.) MAX. No. of PSUs on 16A MAX. No. of PSUs on 16A
MAX. No. of PSUs on 16A 91.5% 91.5%
91.5% 0.88A / 115VAC0.45A / 230VAC 0.38A / 277VAC COLD START 60A(twidth=410s measured at 50% Ipeak) at 230VAC 0.88A / 115VAC0.45A / 230VAC 0.38A / 277VAC COLD START 60A(twidth=410s measured at 50% Ipeak) at 230VAC
0.88A / 115VAC0.45A / 230VAC 0.38A / 277VAC COLD START 60A(twidth=410s measured at 50% Ipeak) at 230VAC 91.5% 91.5%
91.5% CIRCUIT BREAKER4 units (circuit breaker of type B) / 8 units(circuit breaker of type C) at 230VAC CIRCUIT BREAKER4 units (circuit breaker of type B) / 8 units(circuit breaker of type C) at 230VAC
CIRCUIT BREAKER4 units (circuit breaker of type B) / 8 units(circuit breaker of type C) at 230VAC LEAKAGE CURRENT SHORT CIRCUIT LEAKAGE CURRENT SHORT CIRCUIT
LEAKAGE CURRENT SHORT CIRCUIT <0.75mA / 277VAC <0.75mA / 277VAC
<0.75mA / 277VAC Hiccup mode, recovers automatically after fault condition is removed Hiccup mode, recovers automatically after fault condition is removed
Hiccup mode, recovers automatically after fault condition is removed 300 ~ 340V 300 ~ 340V
300 ~ 340V 150 ~ 170V 150 ~ 170V
150 ~ 170V PROTECTION PROTECTION
PROTECTION ENVIRONMENT ENVIRONMENT
ENVIRONMENT OVER VOLTAGE OVER VOLTAGE
OVER VOLTAGEOVER TEMPERATURE WORKING TEMP. WORKING HUMIDITY OVER TEMPERATURE WORKING TEMP. WORKING HUMIDITY
OVER TEMPERATURE WORKING TEMP. WORKING HUMIDITY STORAGE TEMP., HUMIDITY STORAGE TEMP., HUMIDITY
STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION TEMP. COEFFICIENT VIBRATION
TEMP. COEFFICIENT VIBRATION Protection type : Shut down o/p voltage with auto-recovery or re-power on to recovery Protection type : Shut down o/p voltage with auto-recovery or re-power on to recovery
Protection type : Shut down o/p voltage with auto-recovery or re-power on to recovery Shut down o/p voltage, re-power on to recover Shut down o/p voltage, re-power on to recover
Shut down o/p voltage, re-power on to recover -40 ~ +70c (Refer to "Derating Curve") -40 ~ +70c (Refer to "Derating Curve")
-40 ~ +70c (Refer to "Derating Curve") 10 ~ 95% RH non-condensing 10 ~ 95% RH non-condensing
10 ~ 95% RH non-condensing -40 ~ +80c, 10 ~ 95% RH -40 ~ +80c, 10 ~ 95% RH
-40 ~ +80c, 10 ~ 95% RH 0.03%/c (0 ~ 50c) 0.03%/c (0 ~ 50c)
0.03%/c (0 ~ 50c) 10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes 10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes
10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes SAFETY STANDARDS Note.3 UL8750, CSA C22.2 No. 250.0-08, EN61347-1, EN61347-2-13 independent, IP65 or IP67, J61347-1, J61347-2-13 approved SAFETY STANDARDS Note.3 UL8750, CSA C22.2 No. 250.0-08, EN61347-1, EN61347-2-13 independent, IP65 or IP67, J61347-1, J61347-2-13 approved
SAFETY STANDARDS Note.3 UL8750, CSA C22.2 No. 250.0-08, EN61347-1, EN61347-2-13 independent, IP65 or IP67, J61347-1, J61347-2-13 approvedSAFETY & EMC SAFETY & EMC
SAFETY & EMCOTHERS OTHERS
OTHERS WITHSTAND VOLTAGE ISOLATION RESISTANCE EMC EMISSION WITHSTAND VOLTAGE ISOLATION RESISTANCE EMC EMISSION
WITHSTAND VOLTAGE ISOLATION RESISTANCE EMC EMISSION EMC IMMUNITY MTBF DIMENSION EMC IMMUNITY MTBF DIMENSION
EMC IMMUNITY MTBF DIMENSION PACKING PACKING
PACKING I/P-O/P:3.75KVAC I/P-FG:2KVACO/P-FG:1.5KVAC I/P-O/P:3.75KVAC I/P-FG:2KVACO/P-FG:1.5KVAC
I/P-O/P:3.75KVAC I/P-FG:2KVACO/P-FG:1.5KVAC I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25c/ 70% RH I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25c/ 70% RH
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25c/ 70% RH Compliance to EN55015, EN61000-3-2 Class C (50% load) ; EN61000-3-3 Compliance to EN55015, EN61000-3-2 Class C (50% load) ; EN61000-3-3
Compliance to EN55015, EN61000-3-2 Class C (50% load) ; EN61000-3-3 Compliance to EN61000-4-2,3,4,5,6,8,11, EN61547, heavy industry level (surge L,N-FG: 4KV), criteria A Compliance to EN61000-4-2,3,4,5,6,8,11, EN61547, heavy industry level (surge L,N-FG: 4KV), criteria A
Compliance to EN61000-4-2,3,4,5,6,8,11, EN61547, heavy industry level (surge L,N-FG: 4KV), criteria A 309.7K hrs min.MIL-HDBK-217F (25c) 309.7K hrs min.MIL-HDBK-217F (25c)
309.7K hrs min.MIL-HDBK-217F (25c) 195.6*61.5*38.8 mm (L*W*H) 195.6*61.5*38.8 mm (L*W*H)
195.6*61.5*38.8 mm (L*W*H) 0.84Kg; 16pcs/14.4Kg/0.54CUFT 0.84Kg; 16pcs/14.4Kg/0.54CUFT
0.84Kg; 16pcs/14.4Kg/0.54CUFTNOTE NOTE
NOTE 1. All parameters NOT speciallymentioned are measured at 230VAC input, ratedload and 25c of ambient temperature. 1. All parameters NOT speciallymentioned are measured at 230VAC input, ratedload and 25c of ambient temperature.
1. All parameters NOT speciallymentioned are measured at 230VAC input, ratedload and 25c of ambient temperature. 2. Deratingmay be needed underlow input voltages. Please checkthe static characteristics for more details. 2. Deratingmay be needed underlow input voltages. Please checkthe static characteristics for more details.
2. Deratingmay be needed underlow input voltages. Please checkthe static characteristics for more details. 3. Safetyand EMC design refer to EN60598-1, CNS15233, GB7000.1. 3. Safetyand EMC design refer to EN60598-1, CNS15233, GB7000.1.
3. Safetyand EMC design refer to EN60598-1, CNS15233, GB7000.1. 4. The powersupply is considered as a component that will be operated in combination with final equipment. SinceEMC performance will be affected by the complete installation,the final equipment manufacturers must re-qualify EMC Directive on the complete installationagain. 4. The powersupply is considered as a component that will be operated in combination with final equipment. SinceEMC performance will be affected by the complete installation,the final equipment manufacturers must re-qualify EMC Directive on the complete installationagain.
4. The powersupply is considered as a component that will be operated in combination with final equipment. SinceEMC performance will be affected by the complete installation,the final equipment manufacturers must re-qualify EMC Directive on the complete installationagain. 5. Referto warrantystatement. 5. Referto warrantystatement.
5. Referto warrantystatement. 6. Please refer to "DRIVING METHODS OF LED MODULE". 6. Please refer to "DRIVING METHODS OF LED MODULE".
6. Please refer to "DRIVING METHODS OF LED MODULE". 7. To fulfill requirements of the latestErP regulation for lighting fixtures, this LED power supply canonly be used behinda switch without permanently connected to the mains. 7. To fulfill requirements of the latestErP regulation for lighting fixtures, this LED power supply canonly be used behinda switch without permanently connected to the mains.
7. To fulfill requirements of the latestErP regulation for lighting fixtures, this LED power supply canonly be used behinda switch without permanently connected to the mains. File Name:HLG-80H-C-SPEC2015-07-23 File Name:HLG-80H-C-SPEC2015-07-23
File Name:HLG-80H-C-SPEC2015-07-23

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.