ELN-60-15D MEANWELL AC-DC Single output LED driver Mix mode (CV+CC), Output 15VDC / 4A, Dimming with 1-10VDC View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

ELN-60-15D MEANWELL AC-DC Single output LED driver Mix mode (CV+CC), Output 15VDC / 4A, Dimming with 1-10VDC

ELN-60-15D

MEANWELL

Available Ship on today

AC-DC Single output LED driver Mix mode (CV+CC), Output 15VDC / 4A, Dimming with 1-10VDC

More details


LED DRIVERS > ELN

* Brand new product in its original packaging covered by the warranties and certifications provided by MEANWELL

* This article may be obsolete. Ask for a quotation and we will check if there are any units available. If not, one of our technicians will look for an alternative solution.

Go to successor article: NPF-60D-15 NPF-60D-15

If our price is not the best, please ask us for a quote. Ask for a quotation

More info



60W Single Output Class 2 Switching Power supply 60W Single Output Class 2 Switching Power supply
60W Single Output Class 2 Switching Power supply ELN-60series ELN-60series
ELN-60seriesFeatures : Features :
Features : UniversalAC input / Full range UniversalAC input / Full range
UniversalAC input / Full range Protections: short circuit / Over current/ Over voltage Protections: short circuit / Over current/ Over voltage
Protections: short circuit / Over current/ Over voltage Cooling by free air convection Cooling by free air convection
Cooling by free air convection Built-in constant currentlimiting circuit with level adjustment OCP Built-in constant currentlimiting circuit with level adjustment OCP
Built-in constant currentlimiting circuit with level adjustment OCP Optional dimming function : 1>10VDC (D type) or PWM (P type) controlled Optional dimming function : 1>10VDC (D type) or PWM (P type) controlled
Optional dimming function : 1>10VDC (D type) or PWM (P type) controlled Fully isolated plastic case with IP64 level Fully isolated plastic case with IP64 level
Fully isolated plastic case with IP64 level Classpower unit, no FG Classpower unit, no FG
Classpower unit, no FG Class 2 power unit Class 2 power unit
Class 2 power unit Pass LPS Pass LPS
Pass LPS Suitable for LED lighting and moving sign applications (Note.s) Suitable for LED lighting and moving sign applications (Note.s)
Suitable for LED lighting and moving sign applications (Note.s) 100% full load burn-in test 100% full load burn-in test
100% full load burn-in test Low cost,high reliability Low cost,high reliability
Low cost,high reliability 2 years warranty 2 years warranty
2 years warranty SPECIFICATION SPECIFICATION
SPECIFICATION LPS LPS
LPS IP64 IP64
IP64( for 48V only) ( except for 48V ) ( for 48V only) ( except for 48V )
( for 48V only) ( except for 48V ) MODEL MODEL
MODEL ELN-60-9 ELN-60-9
ELN-60-9 ELN-60-12 ELN-60-12
ELN-60-12 ELN-60-15ELN-60-24 ELN-60-27ELN-60-48 ELN-60-15ELN-60-24 ELN-60-27ELN-60-48
ELN-60-15ELN-60-24 ELN-60-27ELN-60-48 DC VOLTAGE9V DC VOLTAGE9V
DC VOLTAGE9V LED OPERATION VOLTAGE Note.8 3 ~ 9V LED OPERATION VOLTAGE Note.8 3 ~ 9V
LED OPERATION VOLTAGE Note.8 3 ~ 9V 12V 12V
12V 6 ~ 12V 6 ~ 12V
6 ~ 12V 15V 15V
15V 7.5 ~ 15V 7.5 ~ 15V
7.5 ~ 15V 24V 24V
24V 12 ~ 24V 12 ~ 24V
12 ~ 24V 27V 27V
27V 13.5 ~ 27V 13.5 ~ 27V
13.5 ~ 27V 48V 48V
48V 24 ~ 48V 24 ~ 48V
24 ~ 48V NOMINAL CURRENT5A NOMINAL CURRENT5A
NOMINAL CURRENT5A 5A 4A 5A 4A
5A 4A 2.5A2.3A 2.5A2.3A
2.5A2.3A 1.3 A 1.3 A
1.3 A CURRENT RANGE CURRENT RANGE
CURRENT RANGE 0 ~ 5A 0 ~ 5A
0 ~ 5A 0 ~ 5A 0 ~ 5A
0 ~ 5A 0 ~ 4A 0 ~ 4A
0 ~ 4A 0 ~ 2.5A0 ~ 2.3 A 0 ~ 1.3 A 0 ~ 2.5A0 ~ 2.3 A 0 ~ 1.3 A
0 ~ 2.5A0 ~ 2.3 A 0 ~ 1.3 A RATED POWER RATED POWER
RATED POWER 45W 45W
45W 60W 60W
60W 60W 60W62.1W62.5W 60W 60W62.1W62.5W
60W 60W62.1W62.5W RIPPLE & NOISE (max.) Note.2120mVp-p RIPPLE & NOISE (max.) Note.2120mVp-p
RIPPLE & NOISE (max.) Note.2120mVp-p 8.7 ~ 10.5 V 8.7 ~ 10.5 V
8.7 ~ 10.5 V 120mVp-p 120mVp-p
120mVp-p 10.8 ~ 13.2 V 10.8 ~ 13.2 V
10.8 ~ 13.2 V 150mVp-p 150mVp-p
150mVp-p 13.5 ~ 16.5 V 13.5 ~ 16.5 V
13.5 ~ 16.5 V 150mVp-p 150mVp-p
150mVp-p 21.6 ~ 26.4 V 21.6 ~ 26.4 V
21.6 ~ 26.4 V 200mVp-p 200mVp-p
200mVp-p 24.3 ~ 29.7 V 24.3 ~ 29.7 V
24.3 ~ 29.7 V 250mVp-p 250mVp-p
250mVp-p 43.2 ~ 52.8 V 43.2 ~ 52.8 V
43.2 ~ 52.8 V OUTPUT VOLTAGE ADJ. RANGE of Note.7 OUTPUT VOLTAGE ADJ. RANGE of Note.7
OUTPUT VOLTAGE ADJ. RANGE of Note.7 Can be adjusted by internal potentiometer SVR1 Can be adjusted by internal potentiometer SVR1
Can be adjusted by internal potentiometer SVR1 CURRENT ADJ. RANGE of Note.7-25% ~ 3%. Can be adjusted by internal potentiometer SVR2 CURRENT ADJ. RANGE of Note.7-25% ~ 3%. Can be adjusted by internal potentiometer SVR2
CURRENT ADJ. RANGE of Note.7-25% ~ 3%. Can be adjusted by internal potentiometer SVR2 VOLTAGE TOLERANCE Note.35.0% VOLTAGE TOLERANCE Note.35.0%
VOLTAGE TOLERANCE Note.35.0% LINE REGULATION LOAD REGULATION LINE REGULATION LOAD REGULATION
LINE REGULATION LOAD REGULATION 1.0% 1.0%
1.0% 2.0% 2.0%
2.0% SETUP, RISE TIME Note.6500ms, 30ms / 230VAC1500ms, 30ms / 115VAC at full load SETUP, RISE TIME Note.6500ms, 30ms / 230VAC1500ms, 30ms / 115VAC at full load
SETUP, RISE TIME Note.6500ms, 30ms / 230VAC1500ms, 30ms / 115VAC at full load HOLD TIME (Typ.) HOLD TIME (Typ.)
HOLD TIME (Typ.) 50ms/230VAC16ms/115VAC at full load 50ms/230VAC16ms/115VAC at full load
50ms/230VAC16ms/115VAC at full load VOLTAGE RANGE Note.4 90 ~ 264VAC127 ~ 370VDC VOLTAGE RANGE Note.4 90 ~ 264VAC127 ~ 370VDC
VOLTAGE RANGE Note.4 90 ~ 264VAC127 ~ 370VDC INPUT INPUT
INPUT FREQUENCY RANGE EFFICIENCY (Typ.) AC CURRENT (Typ.) FREQUENCY RANGE EFFICIENCY (Typ.) AC CURRENT (Typ.)
FREQUENCY RANGE EFFICIENCY (Typ.) AC CURRENT (Typ.) INRUSH CURRENT (Typ.) INRUSH CURRENT (Typ.)
INRUSH CURRENT (Typ.) MAX. No. of the power systems on the 16A CIRCUIT BREAKER MAX. No. of the power systems on the 16A CIRCUIT BREAKER
MAX. No. of the power systems on the 16A CIRCUIT BREAKER THE LEAKAGE CURRENT THE LEAKAGE CURRENT
THE LEAKAGE OF CURRENTOVER CURRENT MORE CURRENT
MORE CURRENT 47 ~ 63Hz 47 ~ 63Hz
47 ~ 63Hz 82%85%86%87%87% 88% 82%85%86%87%87% 88%
82%85%86%87%87% 88% 1.2 A/115VAC 0.7 A/230VAC 1.2 A/115VAC 0.7 A/230VAC
1.2 A/115VAC 0.7 A/230VAC COLD start 60A(twidth=600 measured at 50% Ipeak) at 230VAC COLD start 60A(twidth=600 measured at 50% Ipeak) at 230VAC
COLD start 60A(twidth=600 measured at 50% Ipeak) at 230VAC3 units (circuit breaker type B) / 5 units (circuit breaker type C) 230VAC 3 units (circuit breaker type B) / 5 units (circuit breaker type C) 230VAC
3 units (circuit breaker type B) / 5 units (circuit breaker type C) in 230VAC0.25mA / 240VAC 0.25 mA / 240VAC
0.25 mA / 240VAC 95 ~ 110% 95 ~ 110%
95 ~ 110% Protection type : Constant current limiting, recovers automatically after fault condition is removed Protection type : Constant current limiting, recovers automatically after fault condition is removed
Protection type : Constant current limiting, recovers automatically after fault condition is removed PROTECTION PROTECTION
PROTECTION 11 ~ 13.5 V 11 ~ 13.5 V
11 ~ 13.5 V 13.8 ~ 16V 13.8 ~ 16V
13.8 ~ 16V 17.5 ~ 21V 28 ~ 32V 31 ~ 37V54 ~ 60V 17.5 ~ 21V 28 ~ 32V 31 ~ 37V54 ~ 60V
17.5 ~ 21V 28 ~ 32V 31 ~ 37V54 ~ 60V OVER VOLTAGE OVER VOLTAGE
OVER VOLTAGE Protection type : Shut down o/p voltage, re-power on to recover Protection type : Shut down o/p voltage, re-power on to recover
Protection type : Shut down o/p voltage, re-power on to recover The FUNCTION DIMMING CONTROL (OPTIONAL)1 ~ 10VDC or PWM signal : 100Hz ~ 3KHz The FUNCTION DIMMING CONTROL (OPTIONAL)1 ~ 10VDC or PWM signal : 100Hz ~ 3KHz
The FUNCTION DIMMING CONTROL (OPTIONAL)1 ~ 10VDC or PWM signal : 100Hz ~ 3KHzENVIRONMENT ENVIRONMENT
ENVIRONMENT SAFETY AND EMC SAFETY AND EMC
SECURITY AND EMCOTHERS OTHER
OTHER WORKING TEMP. OPERATING HUMIDITY STORAGE TEMPERATURE, HUMIDITY TEMP. COEFFICIENT VIBRATION WORKING TEMP. OPERATING HUMIDITY STORAGE TEMPERATURE, HUMIDITY TEMP. COEFFICIENT VIBRATION
WORKING TEMP. OPERATING HUMIDITY STORAGE TEMPERATURE, HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS VOLTAGE RESISTANCE ISOLATION RESISTANCE EMC EMISSION SAFETY STANDARDS VOLTAGE RESISTANCE ISOLATION RESISTANCE EMC EMISSION
SAFETY STANDARDS VOLTAGE RESISTANCE ISOLATION RESISTANCE EMC EMISSION EMC IMMUNITY MTBF DIMENSION EMC IMMUNITY MTBF DIMENSION
EMC IMMUNITY MTBF DIMENSION PACKAGING PACKAGING
PACKAGING -20 ~ +60 (Refer to "Reduction Curve") -20 ~ +60 (Refer to "Reduction Curve")
-20 ~ +60 (Refer to "Reduction Curve") 20 ~ 90% RH non-condensing 20 ~ 90% RH non-condensing
20 ~ 90% RH non-condensing -40 ~ +80, 10 ~ 95% RH -40 ~ +80, 10 ~ 95% RH
-40 ~ +80, 10 ~ 95% RH 0.03%/ (0 ~ 50) 0.03%/ (0 ~ 50)
0.03%/ (0 ~ 50) 10 ~ 500Hz, 2G 10min./1cycle, period for 60 min. each along X, y, Z axes 10 ~ 500Hz, 2G 10min./1cycle, period for 60 min. each along X, y, Z axes
10 ~ 500Hz, 2G 10min./1cycle, period for 60 min. each along X, y, Z axes UL1310, CAN/CSA C22.2 No. 223-M91(except for 48V), IP64 approved ; design refer to TUV EN60950-1 UL1310, CAN/CSA C22.2 No. 223-M91(except for 48V), IP64 approved ; design refer to TUV EN60950-1
UL1310, CAN/CSA C22.2 No. 223-M91(except for 48V), IP64 approved ; design refer to TUV EN60950-1 I/P-O/P:3KVAC I/P-O/P:3KVAC
I/P-O/P:3KVAC I/P-O/P:>100m Ohms / 500VDC / 25/ 70% RH I/P-O/P:>100m Ohms / 500VDC / 25/ 70% RH
I/P-O/P:>100m Ohms / 500VDC / 25/ 70% RH Compliance to EN55022 (CISPR22) Class B, EN61000-3-2 Class a, EN61000-3-3 Compliance to EN55022 (CISPR22) Class B, EN61000-3-2 Class a, EN61000-3-3
Compliance to EN55022 (CISPR22) Class B, EN61000-3-2 Class a, EN61000-3-3 Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, light industry level,criteria A Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, light industry level,criteria A
Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, light industry level,criteria A 603Khrs min.MIL-HDBK-217F (25) 603Khrs min.MIL-HDBK-217F (25)
603Khrs min.MIL-HDBK-217F (25) 181*61.5*35 mm (L*W*H) 181*61.5*35 mm (L*W*H)
181*61.5*35 mm (L*W*H) 0.4 Kg; 24pcs/11Kg/0.75 CUFT 0.4 Kg; 24pcs/11Kg/0.75 CUFT
0.4 Kg; 24pcs/11Kg/0.75 CUFTNOTE NOTE
NOTE 1. All the parameters are NOT speciallymentioned are measured at 230vac input, ratedload and 25 of ambient temperature. 1. All the parameters are NOT speciallymentioned are measured at 230vac input, ratedload and 25 of ambient temperature.
1. All the parameters are NOT speciallymentioned are measured at 230vac input, ratedload and 25 of ambient temperature. 2. Curly and noiseare measured at 20 mhz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1 uf & 47uf parallel capacitor. 2. Curly and noiseare measured at 20 mhz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1 uf & 47uf parallel capacitor.
2. Curly and noiseare measured at 20 mhz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1 uf & 47uf parallel capacitor. 3. Tolerance : includes setup tolerance, line regulation and load regulation. 3. Tolerance : includes setup tolerance, line regulation and load regulation.
3. Tolerance : includes setup tolerance, line regulation and load regulation. 4. Deratingmay be necessary underlow of the input voltage.Please checkthe static characteristics for more details. 4. Deratingmay be necessary underlow of the input voltage.Please checkthe static characteristics for more details.
4. Deratingmay be necessary underlow of the input voltage.Please checkthe static characteristics for more details. 5. The supply is considered a component which will be operated in combination with final equipment. SinceEMC the performance will be affected by the complete installation,the final equipment manufacturers must re-qualify EMC Directive on the complete installationagain. 5. The supply is considered a component which will be operated in combination with final equipment. SinceEMC the performance will be affected by the complete installation,the final equipment manufacturers must re-qualify EMC Directive on the complete installationagain.
5. The supply is considered a component which will be operated in combination with final equipment. SinceEMC the performance will be affected by the complete installation,the final equipment manufacturers must re-qualify EMC Directive on the complete installationagain. 6. Lengthof installation time is measured at first cold start.Turn on/OFF the supply can lead to the increase of the setup time. 6. Lengthof installation time is measured at first cold start.Turn on/OFF the supply can lead to the increase of the setup time.
6. Lengthof installation time is measured at first cold start.Turn on/OFF the supply can lead to the increase of the setup time. 7. Outputvoltagecanbe adjusted through SVR1 on the PCB ; limit of output constant currentlevel can be adjusted through the SVR2 on the PCB. 7. Outputvoltagecanbe adjusted through SVR1 on the PCB ; limit of output constant currentlevel can be adjusted through the SVR2 on the PCB.
7. Outputvoltagecanbe adjusted through SVR1 on the PCB ; limit of output constant currentlevel can be adjusted through the SVR2 on the PCB. 8. Constant currentoperation region is within the specified output voltagerange up. This is the suitable operation region for LED related applications. s. The unit may not be suitable for lighting applications in EU countries. Please checkwith the local authorities for the possible use of the unit. 8. Constant currentoperation region is within the specified output voltagerange up. This is the suitable operation region for LED related applications. s. The unit may not be suitable for lighting applications in EU countries. Please checkwith the local authorities for the possible use of the unit.
8. Constant currentoperation region is within the specified output voltagerange up. This is the suitable operation region for LED related applications. s. The unit may not be suitable for lighting applications in EU countries. Please checkwith the local authorities for the possible use of the unit.File name:ELN-60-SPEC2015-05-28 File name:ELN-60-SPEC2015-05-28
File name:ELN-60-SPEC2015-05-28

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.