TN-3000-248B MEANWELL DC-AC Solar inverter with battery charger for stand alone solar systems, battery 48VDC.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

TN-3000-248B MEANWELL DC-AC Solar inverter with battery charger for stand alone solar systems, battery 48VDC..

TN-3000-248B

MEANWELL

Available Ship on today

DC-AC Solar inverter with battery charger for stand alone solar systems, battery 48VDC, Output 230VAC, 3000W, EU AC Output receptacle

More details


INVERTERS > TN

* Brand new product in its original packaging covered by the warranties and certifications provided by MEANWELL

Total price: $1,047.41
Unit price: $1,047.41

*This price is per unit and is the net value (not including taxes if applicable).

If our price is not the best, please ask us for a quote. Ask for a quotation

More info



3000W Sine Wa ve DC-AC Inverter with Solar Charger TN-3000series 3000W Sine Wa ve DC-AC Inverter with Solar Charger TN-3000series
3000W Sine Wa ve DC-AC Inverter with Solar Charger TN-3000seriesFeatures : Features :
Features : Sine wave output (THD<3%) Sine wave output (THD<3%)
Sine wave output (THD<3%) High power up to 6000W High power up to 6000W
High power up to 6000W U. P. S. mode and energy saving mode (selectable) U. P. S. mode and energy saving mode (selectable)
U. P. S. mode and energy saving mode (selectable) High efficiency of up to 92% High efficiency of up to 92%
High efficiency of up to 92% Power on-OFF switch Power on-OFF switch
Power on-OFF switch Standby saving mode can be selectable Standby saving mode can be selectable
Standby saving mode can be selectable Front Panel indicatorfor state of operation Front Panel indicatorfor state of operation
Front Panel indicatorfor state of operation Thermostat-controlled cooling fan Thermostat-controlled cooling fan
Thermostat-controlled cooling fan Protections: Bat. low alarm / Bat. low shutdown / Over voltage / Over temperature. Protections: Bat. low alarm / Bat. low shutdown / Over voltage / Over temperature.
Protections: Bat. low alarm / Bat. low shutdown / Over voltage / Over temperature. / Output short / Input polarity reverse / Overload / AC circuit breaker / Output short / Input polarity reverse / Overload / AC circuit breaker
/ Output short / Input polarity reverse / Overload / AC circuit breaker Application : home appliances, power tools, office and portable Application : home appliances, power tools, office and portable
Application : home appliances, power tools, office and portable equipment, motor vehicles, and yachts, etc ... equipment, motor vehicles, and yachts, etc ...
equipment, motor vehicles, and yachts, etc ... Built in solar / AC charger Built in solar / AC charger
Built in solar / AC charger Computer-based monitoring software (Note.7) Computer-based monitoring software (Note.7)
Computer-based monitoring software (Note.7) 3 years warranty 3 years warranty
3 years warrantySPECIFICATION SPECIFICATION
SPECIFICATION MODEL MODEL
MODEL E13 E13
E13TN-3000-112 TN-3000-124 TN-3000-148 TN-3000-212 TN-3000-224 TN-3000-248 TN-3000-112 TN-3000-124 TN-3000-148 TN-3000-212 TN-3000-224 TN-3000-248
TN-3000-112 TN-3000-124 TN-3000-148 TN-3000-212 TN-3000-224 TN-3000-248 RATED POWER (Typ.)3000W RATED POWER (Typ.)3000W
RATED POWER (Typ.)3000W MAXIMUM OUTPUT POWER (Typ.) 3450W for 180 sec. / 4500W for 10 sec. / power 6000W for 30 cycles MAXIMUM OUTPUT POWER (Typ.) 3450W for 180 sec. / 4500W for 10 sec. / power 6000W for 30 cycles
MAXIMUM OUTPUT POWER (Typ.) 3450W for 180 sec. / 4500W for 10 sec. / power 6000W for 30 cycles Factory setting set at 110VACFactory set to 230VAC Factory setting set at 110VACFactory set to 230VAC
Factory setting set at 110VACFactory set to 230VAC OUTPUT OUTPUT
OUTPUT THE AC VOLTAGE THE AC VOLTAGE
AC VOLTAGEFREQUENCY FREQUENCY
FREQUENCY 100 / 110 / 115 / 120VACselectable by setting button S. W 100 / 110 / 115 / 120VACselectable by setting button S. W
100 / 110 / 115 / 120VACselectable by setting button S. W 600.1 Hz 50/60 hz selectable by setting button S. W 600.1 Hz 50/60 hz selectable by setting button S. W
600.1 Hz 50/60 hz selectable by setting button S. W 200 / 220 / 230 / 240VACselectable by setting button S. W 200 / 220 / 230 / 240VACselectable by setting button S. W
200 / 220 / 230 / 240VACselectable by setting button S. W 500.1 Hz 50/60 hz selectable by setting button S. W 500.1 Hz 50/60 hz selectable by setting button S. W
500.1 Hz 50/60 hz selectable by setting button S. W WAVEFORM of the Note.8True sine wave (THD<3%) WAVEFORM of the Note.8True sine wave (THD<3%)
WAVEFORM of the Note.8True sine wave (THD<3%) AC REGULATION (Typ.) The TRANSFER TIME (Typ.) SAVING MODE (Typ.) AC REGULATION (Typ.) The TRANSFER TIME (Typ.) SAVING MODE (Typ.)
AC REGULATION (Typ.) The TRANSFER TIME (Typ.) SAVING MODE (Typ.) INDICATOR ON THE FRONT PANEL INDICATOR ON THE FRONT PANEL
INDICATOR ON THE FRONT PANEL 3% 3%
3% 10ms inverterby pass 10ms inverterby pass
10ms inverterby pass Disabled by default. Load5W will switch to the standby mode Disabled by default. Load5W will switch to the standby mode
Disabled by default. Load5W will switch to the standby mode The battery voltage level, output load level, saving mode, fault and operation status The battery voltage level, output load level, saving mode, fault and operation status
The battery voltage level, output load level, saving mode, fault and operation status BAT. VOLTAGE BAT. VOLTAGE
BAT. VOLTAGE 12V 12V
12V 24V 24V
24V 48V 48V
48V 12V 12V
12V 24V 24V
24V 48V 48V
48V VOLTAGE RANGE (Typ.) Note.3,6 10.5 ~ 15VDC VOLTAGE RANGE (Typ.) Note.3,6 10.5 ~ 15VDC
VOLTAGE RANGE (Typ.) Note.3,6 10.5 ~ 15VDC DC CURRENT (Typ.) Note.4300A DC CURRENT (Typ.) Note.4300A
DC CURRENT (Typ.) Note.4300A 21 ~ 30VDC 21 ~ 30VDC
21 ~ 30VDC 150A 150A
150A 42 ~ 60VDC 42 ~ 60VDC
42 ~ 60VDC 75A 75A
75A 10.5 ~ 15VDC 10.5 ~ 15VDC
10.5 ~ 15VDC 300A 300A
300A 21 ~ 30VDC 21 ~ 30VDC
21 ~ 30VDC 150A 150A
150A 42 ~ 60VDC 42 ~ 60VDC
42 ~ 60VDC 75A 75A
75A INPUT INPUT
INPUT NO LOAD DISSIPATION (Typ.)10W @ standby saving mode NO LOAD DISSIPATION (Typ.)10W @ standby saving mode
NO LOAD DISSIPATION (Typ.)10W @ standby saving mode Turn OFF MODE CURRENT consumption (Typ.) 1mA Turn OFF MODE CURRENT consumption (Typ.) 1mA
Turn OFF MODE CURRENT consumption (Typ.) 1mA EFFICIENCY (Typ.) Note.188% EFFICIENCY (Typ.) Note.188%
EFFICIENCY (Typ.) Note.188% 90% 90%
90% 91% 91%
91% 89% 89%
89% 91% 91%
91% 92% 92%
92% BATTERY TYPESOpen and sealed lead acid battery BATTERY TYPESOpen and sealed lead acid battery
BATTERY TYPESOpen and sealed lead acid battery FUSE FUSE
FUSE 40A*12 40A*12
40A*12 40A*6 40A*6
40A*6 20A*6 20A*6
20A*6 40A*12 40A*6 20*6 40A*12 40A*6 20*6
40A*12 40A*6 20*6 THE INPUT OF THE BATTERY THE INPUT OF THE BATTERY
THE INPUT OF THE BATTERY BAT. LOW ALARM Note.611.3 V BAT. LOW ALARM Note.611.3 V
BAT. LOW ALARM Note.611.3 V 22.5 V 22.5 V
22.5 V 45V 45V
45V 11.3 V 22.5 V 45V 11.3 V 22.5 V 45V
11.3 V 22.5 V 45V PROTECTIONBAT. LOW SHUTDOWNNote.610.5 V PROTECTIONBAT. LOW SHUTDOWNNote.610.5 V
PROTECTIONBAT. LOW SHUTDOWNNote.610.5 V 21V 21V
21V 42V 42V
42V 10.5 V 21V42V 10.5 V 21V42V
10.5 V 21V42V OUTPUT OUTPUT
OUTPUT REVERSE POLARITY OVER TEMPERATURE OUTPUT SHORT REVERSE POLARITY OVER TEMPERATURE OUTPUT SHORT
REVERSE POLARITY OVER TEMPERATURE OUTPUT SHORT By internal fuse open By internal fuse open
By internal fuse open 90 5 85 5 85 5 80 5 75 5 75 5 90 5 85 5 85 5 80 5 75 5 75 5
90 5 85 5 85 5 80 5 75 5 75 5 Protection type : Shut down o/p voltage, re-power on to recover Protection type : Shut down o/p voltage, re-power on to recover
Protection type : Shut down o/p voltage, re-power on to recover Protection type : Shut down o/p voltage, re-power on to recover Protection type : Shut down o/p voltage, re-power on to recover
Protection type : Shut down o/p voltage, re-power on to recover 105 ~ 115% loadfor 180 sec., 115% ~ 150% load for 10 sec. 105 ~ 115% loadfor 180 sec., 115% ~ 150% load for 10 sec.
105 ~ 115% loadfor 180 sec., 115% ~ 150% load for 10 sec. PROTECTIONOVER LOAD (Typ.) PROTECTIONOVER LOAD (Typ.)
PROTECTIONOVER LOAD (Typ.)CIRCUIT BREAKER CIRCUIT BREAKER
CIRCUIT BREAKER Protection type : Shut down o/p voltage, re-power on to recover Protection type : Shut down o/p voltage, re-power on to recover
Protection type : Shut down o/p voltage, re-power on to recover AC output: 40A, AC receptacle:15A AC output: 40A, AC receptacle:15A
AC output: 40A, AC receptacle:15A AC output: 20A, AC receptacle: 15A AC output: 20A, AC receptacle: 15A
AC output: 20A, AC receptacle: 15A GFCI PROCTECTION GFCI PROCTECTION
GFCI PROCTECTION Optional (Only type F) None Optional (Only type F) None
Optional (Only type F) None WORKING TEMP.Note.20 ~ +40 @ 100% load ; 60 @ 50% load WORKING TEMP.Note.20 ~ +40 @ 100% load ; 60 @ 50% load
WORKING TEMP.Note.20 ~ +40 @ 100% load ; 60 @ 50% loadENVIRONMENT ENVIRONMENT
ENVIRONMENT WORKING HUMIDITY WORKING HUMIDITY
WORKING HUMIDITY STORAGE TEMP., The MOISTURE STORAGE TEMP., The MOISTURE
STORAGE TEMP., The MOISTURE 20% ~ 90% RH non-condensing 20% ~ 90% RH non-condensing
20% ~ 90% RH non-condensing -30 ~ +70 / -22 ~ +158oF, 10 ~ 95% RH -30 ~ +70 / -22 ~ +158oF, 10 ~ 95% RH
-30 ~ +70 / -22 ~ +158oF, 10 ~ 95% RH VIBRATION 10 ~ 500Hz, 3G 10min./1cycle, 60min. each along X, y, Z axes VIBRATION 10 ~ 500Hz, 3G 10min./1cycle, 60min. each along X, y, Z axes
VIBRATION 10 ~ 500Hz, 3G 10min./1cycle, 60min. each along X, y, Z axes SAFETY STANDARDS SAFETY STANDARDS
SAFETY STANDARDS UL458 (only for Type G ) UL458 (only for Type G )
UL458 (only for Type G ) None None
None LVD NoneEN60950-1 LVD NoneEN60950-1
LVD NoneEN60950-1 SAFETY AND EMC SAFETY AND EMC
SAFETY AND EMC VOLTAGE RESISTANCE INSULATION RESISTANCE VOLTAGE RESISTANCE INSULATION RESISTANCE
VOLTAGE RESISTANCE INSULATION RESISTANCE Bat I/P - ACI/P:3.0 KVAC Bat I/P - ACO/P:3.0 KVAC AC O/P - FG:1.5 KVAC Bat I/P - ACI/P:3.0 KVAC Bat I/P - ACO/P:3.0 KVAC AC O/P - FG:1.5 KVAC
Bat I/P - ACI/P:3.0 KVAC Bat I/P - ACO/P:3.0 KVAC AC O/P - FG:1.5 KVAC Bat I/P - ACO/P, Bat I/P - FG, AC O/P - FG: 100M ohms / 500VDC / 25/ 70% RH Bat I/P - ACO/P, Bat I/P - FG, AC O/P - FG: 100M ohms / 500VDC / 25/ 70% RH
Bat I/P - ACO/P, Bat I/P - FG, AC O/P - FG: 100M ohms / 500VDC / 25/ 70% RH EMC EMISSION EMC EMISSION
EMC EMISSION EMC IMMUNITY EMC IMMUNITY
EMC IMMUNITY Compliance to FCC class a None Compliance to FCC class a None
Compliance to FCC class a None Compliance to EN55022 class a, 72/ 245/ CEE, 95/ 54/ CE, E-Mark Compliance to EN55022 class a, 72/ 245/ CEE, 95/ 54/ CE, E-Mark
Compliance to EN55022 class a, 72/ 245/ CEE, 95/ 54/ CE, E-Mark Compliance to EN61000-4-2,3,4,5,6,8,11 Compliance to EN61000-4-2,3,4,5,6,8,11
Compliance to EN61000-4-2,3,4,5,6,8,11 ACCHARGE CURRENT (Typ.) ACCHARGE CURRENT (Typ.)
ACCHARGE CURRENT (Typ.) 25A 25A
25A 12A6A 12A6A
12A6A 25A 25A
25A 12A6A 12A6A
12A6A CHARGER CHARGER
CHARGERSOLAR PANEL SOLAR PANEL
SOLAR PANEL The CHARGING VOLTAGE is noted.6 14.3 V MAX. OPEN CIRCUIT VOLTAGE 25V SHORT CIRCUIT CURRENT (max.) 30A The CHARGING VOLTAGE is noted.6 14.3 V MAX. OPEN CIRCUIT VOLTAGE 25V SHORT CIRCUIT CURRENT (max.) 30A
The CHARGING VOLTAGE is noted.6 14.3 V MAX. OPEN CIRCUIT VOLTAGE 25V SHORT CIRCUIT CURRENT (max.) 30A CONTROL of WIRINGNote.7 RJ11 -RS232 CONTROL of WIRINGNote.7 RJ11 -RS232
CONTROL of WIRINGNote.7 RJ11 -RS232 28.5 V 28.5 V
28.5 V 45V 45V
45V 57V 57V
57V 75V 75V
75V 14.3 V 14.3 V
14.3 V 25V 25V
25V 28.5 V 28.5 V
28.5 V 45V 45V
45V 57V 57V
57V 75V 75V
75V OTHER OTHER
OTHER DIMENSION DIMENSION
DIMENSION 466.8*283.5*100 mm (L*W*H) 466.8*283.5*100 mm (L*W*H)
466.8*283.5*100 mm (L*W*H) PACKAGING 12.9 Kg; 1pcs/14Kg/1.49 CUFT PACKAGING 12.9 Kg; 1pcs/14Kg/1.49 CUFT
PACKAGING 12.9 Kg; 1pcs/14Kg/1.49 CUFT NOTE 1.The efficiency is testedby 2100W, linearload at 13V, 26V, 52V input voltage. NOTE 1.The efficiency is testedby 2100W, linearload at 13V, 26V, 52V input voltage.
NOTE 1.The efficiency is testedby 2100W, linearload at 13V, 26V, 52V input voltage. 2.The output of the reduction capacity refers to curve1. 2.The output of the reduction capacity refers to curve1.
2.The output of the reduction capacity refers to curve1. 3.De input, the reduction capacity refers to curve2. 3.De input, the reduction capacity refers to curve2.
3.De input, the reduction capacity refers to curve2. 4.DCcurrent is testedby 3000W, linearload to 12V, 24V, 48V inputvoltage. 4.DCcurrent is testedby 3000W, linearload to 12V, 24V, 48V inputvoltage.
4.DCcurrent is testedby 3000W, linearload to 12V, 24V, 48V inputvoltage. 5.Allparameters not specified above are measured at ratedload,and 25 of ambient temperature and set to the factory default settings. 5.Allparameters not specified above are measured at ratedload,and 25 of ambient temperature and set to the factory default settings.
5.Allparameters not specified above are measured at ratedload,and 25 of ambient temperature and set to the factory default settings. 6.Thetolerance of eachvoltage valueby models is:112/2120.5 V;124/2241V;148/2482V. 6.Thetolerance of eachvoltage valueby models is:112/2120.5 V;124/2241V;148/2482V.
6.Thetolerance of eachvoltage valueby models is:112/2120.5 V;124/2241V;148/2482V. 7.Thecableis closed for the connection between TN-3000 and the computer to the monitoring software. 7.Thecableis closed for the connection between TN-3000 and the computer to the monitoring software.
7.Thecableis closed for the connection between TN-3000 and the computer to the monitoring software. 8.THD is testedby 3000W, linearload in 13,26,52 V inputvoltage. 8.THD is testedby 3000W, linearload in 13,26,52 V inputvoltage.
8.THD is testedby 3000W, linearload in 13,26,52 V inputvoltage.File name:TN-3000-SPEC 2015-06-24 File name:TN-3000-SPEC 2015-06-24
File name:TN-3000-SPEC 2015-06-24

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.