400W Sine Wa ve DC-AC power Inverter
400W Sine Wa ve DC-AC power Inverter
400W Sine Wa ve DC-AC power Inverter
TS-400series
TS-400series
TS-400seriesFeatures :
Features :
Features :
Sine wave output (THD<3%)
Sine wave output (THD<3%)
Sine wave output (THD<3%)
Surge power-up to 800W
Surge power-up to 800W
Surge power-up to 800W
High efficiency up to 88.5%
High efficiency up to 88.5%
High efficiency up to 88.5%
Thermostat fan controlledcooling
Thermostat fan controlledcooling
Thermostat fan controlledcooling
Built-in remote ON-OFF control
Built-in remote ON-OFF control
Built-in remote ON-OFF control
Front panelindicator to the state of operation
Front panelindicator to the state of operation
Front panelindicator to the state of operation
Power on-OFF switch
Power on-OFF switch
Power on-OFF switch
Protections: Bat. low alarm / Bat. low shutdown / Over voltage / Over temperature.
Protections: Bat. low alarm / Bat. low shutdown / Over voltage / Over temperature.
Protections: Bat. low alarm / Bat. low shutdown / Over voltage / Over temperature.
/ Outputshort / Input polarity reverse / Overload
/ Outputshort / Input polarity reverse / Overload
/ Outputshort / Input polarity reverse / Overload
Application : home appliances, power tools, office and portable
Application : home appliances, power tools, office and portable
Application : home appliances, power tools, office and portable
equipment, motor vehicles, and yachts, etc ...
equipment, motor vehicles, and yachts, etc ...
equipment, motor vehicles, and yachts, etc ...
3 years warranty
3 years warranty
3 years warrantySPECIFICATION
SPECIFICATION
SPECIFICATION
MODEL
MODEL
MODEL
E13
E13
E13TS-400-112 TS-400-124 TS-400-148 TS-400-212 TS-400-224 TS-400-248
TS-400-112 TS-400-124 TS-400-148 TS-400-212 TS-400-224 TS-400-248
TS-400-112 TS-400-124 TS-400-148 TS-400-212 TS-400-224 TS-400-248
NOMINAL POWER400W
NOMINAL POWER400W
NOMINAL POWER400W
MAXIMUM OUTPUT POWER
MAXIMUM OUTPUT POWER
MAXIMUM OUTPUT POWER
460W for 180 sec. / 600W for 10 sec. power / 800W for 30 cycles(typ.)
460W for 180 sec. / 600W for 10 sec. power / 800W for 30 cycles(typ.)
460W for 180 sec. / 600W for 10 sec. power / 800W for 30 cycles(typ.)
OUTPUT
OUTPUT
OUTPUT
THE AC VOLTAGE FREQUENCY
THE AC VOLTAGE FREQUENCY
THE AC VOLTAGE FREQUENCY
Factory setting set at 110VAC
Factory setting set at 110VAC
Factory setting set at 110VAC
100 / 110 / 115 / 120 v ac-selectable by setting button S. W
100 / 110 / 115 / 120 v ac-selectable by setting button S. W
100 / 110 / 115 / 120 v ac-selectable by setting button S. W
600.1 Hz 50/60 hz selectable by setting button
600.1 Hz 50/60 hz selectable by setting button
600.1 Hz 50/60 hz selectable by setting button
Factory setting set at 230VAC
Factory setting set at 230VAC
Factory setting set at 230VAC
200 / 220 / 230 / 240VAC selectable by setting button S. W
200 / 220 / 230 / 240VAC selectable by setting button S. W
200 / 220 / 230 / 240VAC selectable by setting button S. W
500.1 Hz 50/60 hz selectable by setting button
500.1 Hz 50/60 hz selectable by setting button
500.1 Hz 50/60 hz selectable by setting button
WAVEFORM of the Note.2 sine wave (THD<3%)
WAVEFORM of the Note.2 sine wave (THD<3%)
WAVEFORM of the Note.2 sine wave (THD<3%)
AC REGULATIONNote.2 3.0% nominal input voltage
AC REGULATIONNote.2 3.0% nominal input voltage
AC REGULATIONNote.2 3.0% nominal input voltage
FRONT PANEL INDICATOR Operation status ; Green : normal, Orange(flashing) : remote control OFF, Red : abnormal
FRONT PANEL INDICATOR Operation status ; Green : normal, Orange(flashing) : remote control OFF, Red : abnormal
FRONT PANEL INDICATOR Operation status ; Green : normal, Orange(flashing) : remote control OFF, Red : abnormal
BAT. VOLTAGE
BAT. VOLTAGE
BAT. VOLTAGE
12V
12V
12V
24V48V
24V48V
24V48V
12V
12V
12V
24V48V
24V48V
24V48V
VOLTAGE RANGE (Typ.) Note.3 10.5 ~ 15VDC
VOLTAGE RANGE (Typ.) Note.3 10.5 ~ 15VDC
VOLTAGE RANGE (Typ.) Note.3 10.5 ~ 15VDC
21 ~ 30VDC
21 ~ 30VDC
21 ~ 30VDC
42 ~ 60VDC
42 ~ 60VDC
42 ~ 60VDC
10.5 ~ 15VDC
10.5 ~ 15VDC
10.5 ~ 15VDC
21 ~ 30VDC
21 ~ 30VDC
21 ~ 30VDC
42 ~ 60VDC
42 ~ 60VDC
42 ~ 60VDC
DC CURRENT (Typ.)
DC CURRENT (Typ.)
DC CURRENT (Typ.)
40A
40A
40A
20A
20A
20A
10A
10A
10A
40A
40A
40A
20A
20A
20A
10A
10A
10A
INPUT
INPUT
INPUT
NO-LOAD CURRENT (Typ.) 1.25 a OFF MODE CURRENT of 1mA EFFICIENCY (Typ.)Note.184.5%
NO-LOAD CURRENT (Typ.) 1.25 a OFF MODE CURRENT of 1mA EFFICIENCY (Typ.)Note.184.5%
NO-LOAD CURRENT (Typ.) 1.25 a OFF MODE CURRENT of 1mA EFFICIENCY (Typ.)Note.184.5%
0.63 A
0.63 A
0.63A86%
86%
86%
0.32 A
0.32 A
0.32A87%
87%
87%
1.25 to
1.25 to
1.25A86%
86%
86%
0.63 A
0.63 A
0.63A87.5%
87.5%
87.5%
0.32 A
0.32 A
0.32A88.5%
88.5%
88.5%
BATTERY TYPES Open & sealed Lead Acid
BATTERY TYPES Open & sealed Lead Acid
BATTERY TYPES Open & sealed Lead Acid
FUSE
FUSE
FUSE
40A*2
40A*2
40A*2
40A*1
40A*1
40A*1
20A*1
20A*1
20A*1
40A*240V*120A*1
40A*240V*120A*1
40A*240V*120A*1
BATTERY INPUT PROTECTION
BATTERY INPUT PROTECTION
BATTERY INPUT PROTECTION
BAT. LOW ALARM
BAT. LOW ALARM
BAT. LOW ALARM
BAT. LOW SHUTDOWN BAT. The POLARITY
BAT. LOW SHUTDOWN BAT. The POLARITY
BAT. LOW SHUTDOWN BAT. POLARITYOVER TEMPERATURE
THE EXCESS OF TEMPERATURE
THE EXCESS OF TEMPERATURE
11.34%
11.34%
11.34%
10.54%
10.54%
10.54%
By internal fuse open
By internal fuse open
By internal fuse open
855
855
Eight hundred fifty five
22.54%
22.54%
22.54%
214%
214%
214%75 5
75 5
75 5
454%
454%
454%
424%
424%
424%70 5
70 5
70 5
11.34%
11.34%
11.34%
10.54%
10.54%
10.54%85 5
85 5
85 5
22.54%
22.54%
22.54%
214%
214%
214%75 5
75 5
75 5
454%
454%
454%
424%
424%
424%70 5
70 5
70 5OUTPUT PROTECTION
OUTPUT PROTECTION
OUTPUT PROTECTIONOUTPUT SHORT OVER LOAD (Typ.)
OUTPUT short OVER LOAD (Typ.)
OUTPUT short OVER LOAD (Typ.)
GFCI PROCTECTION
GFCI PROCTECTION
GFCI PROCTECTION
Protection type : Shut down o/p voltage, re-power on to recover; by internal RTH1 detect power transistor
Protection type : Shut down o/p voltage, re-power on to recover; by internal RTH1 detect power transistor
Protection type : Shut down o/p voltage, re-power on to recover; by internal RTH1 detect power transistor
Protection type : Shut down o/p voltage, re-power on to recover
Protection type : Shut down o/p voltage, re-power on to recover
Protection type : Shut down o/p voltage, re-power on to recover
105 ~ 115% load for 180 sec., 115% ~ 150% load for 10 sec. Protection type : Shut down o/p voltage, re-power on to recover
105 ~ 115% load for 180 sec., 115% ~ 150% load for 10 sec. Protection type : Shut down o/p voltage, re-power on to recover
105 ~ 115% load for 180 sec., 115% ~ 150% load for 10 sec. Protection type : Shut down o/p voltage, re-power on to recover
Optional (Only type F) None
Optional (Only type F) None
Optional (Only type F) None
The REMOTE CONTROLOpen : Normal work ; Short : Remote off
The REMOTE CONTROLOpen : Normal work ; Short : Remote off
The REMOTE CONTROLOpen : Normal work ; Short : Remote off
ENVIRONMENT
ENVIRONMENT
ENVIRONMENT
WORKING TEMP. WORKING HUMIDITY
WORKING TEMP. WORKING HUMIDITY
WORKING TEMP. WORKING HUMIDITY
STORAGE TEMP., The MOISTURE
STORAGE TEMP., The MOISTURE
STORAGE TEMP., The MOISTURE
-10 ~ +40 @ 100% load ; +60 @ 50% load
-10 ~ +40 @ 100% load ; +60 @ 50% load
-10 ~ +40 @ 100% load ; +60 @ 50% load
20% ~ 90% RH non-condensing
20% ~ 90% RH non-condensing
20% ~ 90% RH non-condensing
-30 ~ +70 / -22 ~ +158oF, 10 ~ 95% RH
-30 ~ +70 / -22 ~ +158oF, 10 ~ 95% RH
-30 ~ +70 / -22 ~ +158oF, 10 ~ 95% RH
VIBRATION10 ~ 500Hz, 3G 10min./1cycle, 60min. each along X, y, Z axes
VIBRATION10 ~ 500Hz, 3G 10min./1cycle, 60min. each along X, y, Z axes
VIBRATION10 ~ 500Hz, 3G 10min./1cycle, 60min. each along X, y, Z axes
SAFETY STANDARDS
SAFETY STANDARDS
SAFETY STANDARDS
Design refer to UL458
Design refer to UL458
Design refer to UL458
None
None
None
LVDNoneEN60950-1
LVDNoneEN60950-1
LVDNoneEN60950-1
SAFETY AND EMC
SAFETY AND EMC
SAFETY AND EMC
VOLTAGE RESISTANCE INSULATION RESISTANCE
VOLTAGE RESISTANCE INSULATION RESISTANCE
VOLTAGE RESISTANCE INSULATION RESISTANCE
Bat. I/P - ACO/P:3.0 KVACAC O/P - FG:1.5 KVAC
Bat. I/P - ACO/P:3.0 KVACAC O/P - FG:1.5 KVAC
Bat. I/P - ACO/P:3.0 KVACAC O/P - FG:1.5 KVAC
Bat. I/P-AC O/P, AC O/P-FG:100M Ohms / 500VDC / 25/ 70% RH
Bat. I/P-AC O/P, AC O/P-FG:100M Ohms / 500VDC / 25/ 70% RH
Bat. I/P-AC O/P, AC O/P-FG:100M Ohms / 500VDC / 25/ 70% RH
EMC EMISSION
EMC EMISSION
EMC EMISSION
EMC IMMUNITY
EMC IMMUNITY
EMC IMMUNITY
Compliance to FCC class a None
Compliance to FCC class a None
Compliance to FCC class a None
Compliance to EN55022 class a, 72/ 245/ CEE, 95/ 54/ CE, E-Mark
Compliance to EN55022 class a, 72/ 245/ CEE, 95/ 54/ CE, E-Mark
Compliance to EN55022 class a, 72/ 245/ CEE, 95/ 54/ CE, E-Mark
Compliance to EN61000-4-2,3,8
Compliance to EN61000-4-2,3,8
Compliance to EN61000-4-2,3,8 OTHER
OTHER
OTHER
MTBF 104.7 K hrs min.MIL-HDBK-217F (25)
MTBF 104.7 K hrs min.MIL-HDBK-217F (25)
MTBF 104.7 K hrs min.MIL-HDBK-217F (25)
DIMENSION205*158*67mm (L*W*H)
DIMENSION205*158*67mm (L*W*H)
DIMENSION205*158*67mm (L*W*H)
PACKING1.73Kg; 6pcs/11.4 Kg/1.55 CUFT
PACKING1.73Kg; 6pcs/11.4 Kg/1.55 CUFT
PACKING1.73Kg; 6pcs/11.4 Kg/1.55 CUFT
NOTE 1.The efficiency is tested by 300W, linear load at 13V/26V/52V input voltage.
NOTE 1.The efficiency is tested by 300W, linear load at 13V/26V/52V input voltage.
NOTE 1.The efficiency is tested by 300W, linear load at 13V/26V/52V input voltage.
2.AC regulation and THD are tested by 400W, linear load at 13V/26V/52V input voltage.
2.AC regulation and THD are tested by 400W, linear load at 13V/26V/52V input voltage.
2.AC regulation and THD are tested by 400W, linear load at 13V/26V/52V input voltage.
3.Thetolerance of each voltagevalue by modelsis:112/2120.5 V;124/2241V;148/2482V
3.Thetolerance of each voltagevalue by modelsis:112/2120.5 V;124/2241V;148/2482V
3.Thetolerance of each voltagevalue by modelsis:112/2120.5 V;124/2241V;148/2482V
4.Allparameters not specified aboveare measured at the rated load, 25 of ambient temperature and is set to factorysetting.
4.Allparameters not specified aboveare measured at the rated load, 25 of ambient temperature and is set to factorysetting.
4.Allparameters not specified aboveare measured at the rated load, 25 of ambient temperature and is set to factorysetting.File name:TS-400-SPEC2015-05-27
File name:TS-400-SPEC2015-05-27
File name:TS-400-SPEC2015-05-27