PLP-20-48 MEANWELL AC-DC Single output LED driver Mix mode (CV+CC), Output 48VDC / 0.42A, open frame, I/O wi.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

PLP-20-48 MEANWELL AC-DC Single output LED driver Mix mode (CV+CC), Output 48VDC / 0.42A, open frame, I/O wi..

PLP-20-48

MEANWELL

Available Ship on today

AC-DC Single output LED driver Mix mode (CV+CC), Output 48VDC / 0.42A, open frame, I/O with cable

More details


LED DRIVERS > PLP

* Brand new product in its original packaging covered by the warranties and certifications provided by MEANWELL

* This article may be obsolete. Ask for a quotation and we will check if there are any units available. If not, one of our technicians will look for an alternative solution.

Go to successor article: IDPV-25-48 IDPV-25-48

If our price is not the best, please ask us for a quote. Ask for a quotation

More info



20W Single Output LED Power supply 20W Single Output LED Power supply
20W Single Output LED Power supply PLP-20series PLP-20series
PLP-20seriesFeatures : Features :
Features : UniversalAC input / Full range(up to 277VAC) UniversalAC input / Full range(up to 277VAC)
UniversalAC input / Full range(up to 277VAC) Protections:short circuit/Over current/Over voltage/Over temperature Protections:short circuit/Over current/Over voltage/Over temperature
Protections:short circuit/Over current/Over voltage/Over temperature Cooling by free air convection Cooling by free air convection
Cooling by free air convection Built-in constant currentlimiting circuit with level adjustment OCP Built-in constant currentlimiting circuit with level adjustment OCP
Built-in constant currentlimiting circuit with level adjustment OCP Built-in active PFC function Built-in active PFC function
Built-in active PFC function Classpower unit, no FG Classpower unit, no FG
Classpower unit, no FG Class 2 power unit Class 2 power unit
Class 2 power unit Small and compact size Small and compact size
Small and compact size 100% full load burn-in test 100% full load burn-in test
100% full load burn-in test High reliability,low cost High reliability,low cost
High reliability,low cost Suitable for applications of LED lighting Suitable for applications of LED lighting
Suitable for applications of LED lighting 2 years warranty 2 years warranty
2 years warrantySPECIFICATION SPECIFICATION
SPECIFICATION Bauar t gepr u f t Bauar t gepr u f t
Bauar t gepr u f t Sicherheit egel ma ge Sicherheit egel ma ge
Sicherheit egel ma ge od or s od or s
od or s be wacg be wacg
be wacg www. tuv. com www. tuv. com
www. tuv. com ID 2000000000 ID 2000000000
ID 2000000000 MODEL MODEL
MODEL PLP-20-12 PLP-20-12
PLP-20-12 PLP-20-18 PLP-20-24PLP-20-36 PLP-20-18 PLP-20-24PLP-20-36
PLP-20-18 PLP-20-24PLP-20-36 PLP-20-48 PLP-20-48
PLP-20-48 THE DC VOLTAGE THE DC VOLTAGE
THE DC VOLTAGE 12V 12V
12V 18V 18V
18V 24V 24V
24V 36V 36V
36V 48V 48V
48V CONSTANT CURRENT REGION Note.59 ~ 12V CONSTANT CURRENT REGION Note.59 ~ 12V
CONSTANT CURRENT REGION Note.59 ~ 12V 13.5 ~ 18V 13.5 ~ 18V
13.5 ~ 18V 18 ~ 24V 18 ~ 24V
18 ~ 24V 27 ~ 36V 27 ~ 36V
27 ~ 36V 36 ~ 48V 36 ~ 48V
36 ~ 48V RATED CURRENT CURRENT RANGE RATED CURRENT CURRENT RANGE
RATED CURRENT CURRENT RANGE 1.6 1.6
1.6 0 ~ 1.6 0 ~ 1.6
0 ~ 1.6 1.1A0.8A0.55A 1.1A0.8A0.55A
1.1A0.8A0.55A 0 ~ 1.1A0 ~ 0.8A0 ~ 0.55 A 0 ~ 1.1A0 ~ 0.8A0 ~ 0.55 A
0 ~ 1.1A0 ~ 0.8A0 ~ 0.55 A 0.42 A 0.42 A
0.42 A 0 ~ 0.42 A 0 ~ 0.42 A
0 ~ 0.42 A CURRENT ADJ. RANGE of 75% ~ 100% CURRENT ADJ. RANGE of 75% ~ 100%
CURRENT ADJ. RANGE of 75% ~ 100% RATED POWER RATED POWER
RATED POWER 19.2 W 19.2 W
19.2 W 19.8 19.2 W 19.8 W 19.8 19.2 W 19.8 W
19.8 19.2 W 19.8 W 20.2 W 20.2 W
20.2 WOUTPUT OUTPUT
OUTPUT RIPPLE & NOISE (max.) Note.22.5 Vp-p RIPPLE & NOISE (max.) Note.22.5 Vp-p
RIPPLE & NOISE (max.) Note.22.5 Vp-p VOLTAGE TOLERANCE Note.310% VOLTAGE TOLERANCE Note.310%
VOLTAGE TOLERANCE Note.310% 3.0 Vp-p3.0Vp-p 3.0 Vp-p 3.0 Vp-p3.0Vp-p 3.0 Vp-p
3.0 Vp-p3.0Vp-p 3.0 Vp-p 3.8 Vp-p 3.8 Vp-p
3.8 Vp-p LINE REGULATION LOAD REGULATION SETUP, RISE TIME LINE REGULATION LOAD REGULATION SETUP, RISE TIME
LINE REGULATION LOAD REGULATION SETUP, RISE TIME 3.0% 3.0%
3.0% 10% 10%
10% 500ms / 230VAC2000ms / 115VAC at full load 500ms / 230VAC2000ms / 115VAC at full load
500ms / 230VAC2000ms / 115VAC at full load VOLTAGE RANGENote.490 ~ 277VAC 127~392VDC VOLTAGE RANGENote.490 ~ 277VAC 127~392VDC
VOLTAGE RANGENote.490 ~ 277VAC 127~392VDC FREQUENCY RANGE POWER FACTOR FREQUENCY RANGE POWER FACTOR
FREQUENCY RANGE POWER FACTOR TOTAL HARMONIC DISTORTION TOTAL HARMONIC DISTORTION
TOTAL HARMONIC DISTORTION 47 ~ 63Hz 47 ~ 63Hz
47 ~ 63Hz PF0.9 at 75~100% load, 115VAC/230VAC;PF0.9 in the 85~100% load 277VAC (please refer to "Power Factor Characteristic" curve) THD< 20% when output loading75% at 115VAC/230VAC input and output loading75% at 277VAC input PF0.9 at 75~100% load, 115VAC/230VAC;PF0.9 in the 85~100% load 277VAC (please refer to "Power Factor Characteristic" curve) THD< 20% when output loading75% at 115VAC/230VAC input and output loading75% at 277VAC input
PF0.9 at 75~100% load, 115VAC/230VAC;PF0.9 in the 85~100% load 277VAC (please refer to "Power Factor Characteristic" curve) THD< 20% when output loading75% at 115VAC/230VAC input and output loading75% at 277VAC input EFFICIENCY(Typ.) EFFICIENCY(Typ.)
EFFICIENCY(Typ.) 80% 80%
80% 81%82%83%83.5% 81%82%83%83.5%
81%82%83%83.5% INPUT INPUT
INPUT AC POWER AC POWER
AC POWER INRUSH CURRENT(Typ.) MAX. No. of the systems of power in the 16TH INRUSH CURRENT(Typ.) MAX. No. of the systems of power in the 16TH
INRUSH CURRENT(Typ.) MAX. No. of the systems of power in the 16TH CIRCUIT BREAKER CIRCUIT BREAKER
CIRCUIT BREAKER THE LEAKAGE CURRENT THE LEAKAGE CURRENT
The LEAKAGE of CURRENTOVER of the CURRENT Note.5 ON the CURRENT Note.5
ON the CURRENT Note.5SHORT CIRCUIT SHORT CIRCUIT
SHORT CIRCUIT 0.4 A/115VAC 0.2 A/230VAC 0.15 A/277VAC 0.4 A/115VAC 0.2 A/230VAC 0.15 A/277VAC
0.4 A/115VAC 0.2 A/230VAC 0.15 A/277VAC COLD start 25A(twidth=60 measured at 50% Ipeak) at 230VAC COLD start 25A(twidth=60 measured at 50% Ipeak) at 230VAC
COLD start 25A(twidth=60 measured at 50% Ipeak) at 230VAC92 units (circuit breaker type (B) / 98 units (circuit breaker type C) 230VAC 92 units (circuit breaker type (B) / 98 units (circuit breaker type C) 230VAC
92 units (circuit breaker type (B) / 98 units (circuit breaker type C) in 230VAC0.5mA / 240VAC 0.5 mA / 240VAC
0.5 mA / 240VAC 95 ~ 110% 95 ~ 110%
95 ~ 110% Protection type : Constant current limiting, recovers automatically after fault condition is removed Protection type : Constant current limiting, recovers automatically after fault condition is removed
Protection type : Constant current limiting, recovers automatically after fault condition is removed Hiccup mode, recovers automatically after fault condition is removed. Hiccup mode, recovers automatically after fault condition is removed.
Hiccup mode, recovers automatically after fault condition is removed. PROTECTION PROTECTION
PROTECTION 14 ~ 16V 14 ~ 16V
14 ~ 16V 19 ~ 22V 27 ~ 34V41 ~ 46V54 ~ 60V 19 ~ 22V 27 ~ 34V41 ~ 46V54 ~ 60V
19 ~ 22V 27 ~ 34V41 ~ 46V54 ~ 60VENVIRONMENT ENVIRONMENT
ENVIRONMENTSAFETY & EMC SAFETY AND EMC
SAFETY AND EMC OTHER OTHER
OTHER OVER VOLTAGE OVER VOLTAGE
MOST OF VOLTAGEOVER TEMPERATURE WORKING TEMP. WORKING HUMIDITY THE OVER TEMPERATURE WORKING TEMP. WORKING HUMIDITY
THE OVER TEMPERATURE WORKING TEMP. WORKING HUMIDITY STORAGE TEMP., THE HUMIDITY TEMP. COEFFICIENT VIBRATION STORAGE TEMP., THE HUMIDITY TEMP. COEFFICIENT VIBRATION
STORAGE TEMP., THE HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS VOLTAGE RESISTANCE ISOLATION RESISTANCE EMC EMISSION SAFETY STANDARDS VOLTAGE RESISTANCE ISOLATION RESISTANCE EMC EMISSION
SAFETY STANDARDS VOLTAGE RESISTANCE ISOLATION RESISTANCE EMC EMISSION EMC IMMUNITY MTBF DIMENSION EMC IMMUNITY MTBF DIMENSION
EMC IMMUNITY MTBF DIMENSION PACKAGING PACKAGING
PACKAGING Protection type : Shut off o/p voltage, clamping by zener diode Protection type : Shut off o/p voltage, clamping by zener diode
Protection type : Shut off o/p voltage, clamping by zener diode Shut down o/p voltage, recovers automatically after temperature goes down Shut down o/p voltage, recovers automatically after temperature goes down
Shut down o/p voltage, recovers automatically after temperature goes down -30 ~ +60 (Refer to "Reduction Curve") -30 ~ +60 (Refer to "Reduction Curve")
-30 ~ +60 (Refer to "Reduction Curve") 20 ~ 90% RH non-condensing 20 ~ 90% RH non-condensing
20 ~ 90% RH non-condensing -40 ~ +80, 10 ~ 95% RH -40 ~ +80, 10 ~ 95% RH
-40 ~ +80, 10 ~ 95% RH 0.06%/ (0 ~ 50) 0.06%/ (0 ~ 50)
0.06%/ (0 ~ 50) 10 ~ 500Hz, 2G 10min./1cycle, period for 60 min. each along X, y, Z axes 10 ~ 500Hz, 2G 10min./1cycle, period for 60 min. each along X, y, Z axes
10 ~ 500Hz, 2G 10min./1cycle, period for 60 min. each along X, y, Z axes TUV EN61347-1, EN61347-2-13, GB19510.14, GB19510.1, UL8750, CSA C22.2 No. 250.0-08 approved TUV EN61347-1, EN61347-2-13, GB19510.14, GB19510.1, UL8750, CSA C22.2 No. 250.0-08 approved
TUV EN61347-1, EN61347-2-13, GB19510.14, GB19510.1, UL8750, CSA C22.2 No. 250.0-08 approved I/P-O/P:3.75 KVAC I/P-O/P:3.75 KVAC
I/P-O/P:3.75 KVAC I/P-O/P:100M Ohms/500VDC / 25/ 70% RH I/P-O/P:100M Ohms/500VDC / 25/ 70% RH
I/P-O/P:100M Ohms/500VDC / 25/ 70% RH Compliance to EN55015, GB17743, GB17625.1, EN61000-3-2 Class C(75% load); EN61000-3-3 Compliance to EN55015, GB17743, GB17625.1, EN61000-3-2 Class C(75% load); EN61000-3-3
Compliance to EN55015, GB17743, GB17625.1, EN61000-3-2 Class C(75% load); EN61000-3-3 Compliance to EN61000-4-2,3,4,5,6,8,11, EN61547, light industry level,criteria A Compliance to EN61000-4-2,3,4,5,6,8,11, EN61547, light industry level,criteria A
Compliance to EN61000-4-2,3,4,5,6,8,11, EN61547, light industry level,criteria A 643.6 Khrs min.MIL-HDBK-217F (25) 643.6 Khrs min.MIL-HDBK-217F (25)
643.6 Khrs min.MIL-HDBK-217F (25) 140*32*22(L*W*H) 140*32*22(L*W*H)
140*32*22(L*W*H) 0.12 kg;60pcs/9.2 kg/0.62 CUFT 0.12 kg;60pcs/9.2 kg/0.62 CUFT
0.12 kg;60pcs/9.2 kg/0.62 CUFTNOTE NOTE
NOTE 1. All the parameters are NOT speciallymentioned are measured at 230vac input, ratedload and 25 ° C ambient temperature. 1. All the parameters are NOT speciallymentioned are measured at 230vac input, ratedload and 25 ° C ambient temperature.
1. All the parameters are NOT speciallymentioned are measured at 230vac input, ratedload and 25 ° C ambient temperature. 2. Curly and noiseare measured at 20 mhz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1 uf & 47uf parallel capacitor. 2. Curly and noiseare measured at 20 mhz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1 uf & 47uf parallel capacitor.
2. Curly and noiseare measured at 20 mhz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1 uf & 47uf parallel capacitor. 3. Tolerance : includes setup tolerance, line regulation and load regulation. 3. Tolerance : includes setup tolerance, line regulation and load regulation.
3. Tolerance : includes setup tolerance, line regulation and load regulation. 4. Deratingmay be necessary underlow input voltage,please checkthe feature static for more details. 4. Deratingmay be necessary underlow input voltage,please checkthe feature static for more details.
4. Deratingmay be necessary underlow input voltage,please checkthe feature static for more details. 5. Please refer to "DRIVING METHODS OF LED MODULE". 5. Please refer to "DRIVING METHODS OF LED MODULE".
5. Please refer to "DRIVING METHODS OF LED MODULE". 6. The supply is considered a component which will be installedinto a final computer. All EMC testing has been executed for mountingthe unit on a 360mm*360mm metalplate with 1mm of thickness. The final equipment must be re-confirmed that still meets EMC directives. For information on how to perform these EMC tests, please refer to "EMI testingof component powersupplies." (available in http://www.meanwell.com) 6. The supply is considered a component which will be installedinto a final computer. All EMC testing has been executed for mountingthe unit on a 360mm*360mm metalplate with 1mm of thickness. The final equipment must be re-confirmed that still meets EMC directives. For information on how to perform these EMC tests, please refer to "EMI testingof component powersupplies." (available in http://www.meanwell.com)
6. The supply is considered a component which will be installedinto a final computer. All EMC testing has been executed for mountingthe unit on a 360mm*360mm metalplate with 1mm of thickness. The final equipment must be re-confirmed that still meets EMC directives. For information on how to perform these EMC tests, please refer to "EMI testingof component powersupplies." (available in http://www.meanwell.com) 7. Direct connection to LEDs is suggested, but is not suitable for the use of additionaldrivers. 7. Direct connection to LEDs is suggested, but is not suitable for the use of additionaldrivers.
7. Direct connection to LEDs is suggested, but is not suitable for the use of additionaldrivers. 8. To comply with the requirements of the latestErP regulation of the luminaires, LED supply you canonly be used behinda switch without permanently connected to the electrical grid. 8. To comply with the requirements of the latestErP regulation of the luminaires, LED supply you canonly be used behinda switch without permanently connected to the electrical grid.
8. To comply with the requirements of the latestErP regulation of the luminaires, LED supply you canonly be used behinda switch without permanently connected to the electrical grid. File name:PLP-20-SPEC2016-01-21 File name:PLP-20-SPEC2016-01-21
File name:PLP-20-SPEC2016-01-21

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.