730572 GENERAL ELECTRIC Switch-disconnector-fuse Fulos 2 DIN 400A 3P View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

730572 GENERAL ELECTRIC Switch-disconnector-fuse Fulos 2 DIN 400A 3P

730572

GENERAL ELECTRIC

Available

Ship on today

Switch-disconnector-fuse Fulos 2 DIN 400A 3P

More details


Residual Current Devices Rcd Ground Fault Circuit Interrupter Gfci Breaker Rccb

Industrial

DIFFERENTIAL PROTECTION

* Brand new produt in its original packing covered by the warranties and certifications provided by GENERAL ELECTRIC

QuantityPrice
1+323,99 €
2+321,01 €
*This price is per unit and is the net value (not including taxes if applicable).

Related products

More info



Fulos 2 DIN - 400A

Performance

  • Panel mounting
  • Fused-safety-switch-disconnector (main disconnector)
  • Disconnect function
  • Transparent cover
  • Quick make and quick break mechanism
  • Independent opening and closing
  • Positive contact indication (PCI)
  • Very low power losses
  • Fuse completely disconnected in "OFF"
  • Defeat mechanism rotary handle
  • Double knife contacts - high short-circuit resistance
  • Number of poles 3P - 4P

Standards
  • For disconnectors
    IEC 60947-1 and IEC 60947-3, DIN VDE 0660 Teil 107, BS EN 60947-3, CEI 17-11 (Fasc. 1039), EN 60947-3, NBN EN 60947-3, NF C 63-130
    Safety-switch-disconnector (red/yellow) according to DIN VDE 0113 Teil 1
  • For fuses
    IEC 60269-2-1, BS 88 Parts 2 1988, DIN VDE 0636 Teil 1,NF EN 60269-1, NF C 63-211, NF C 63-210

SPECIFICATIONS

SeriesSwitch-disconnector-fuses - FULOS
Conventional enclosed thermal current Ithe = Ith400 A
Number of poles3P
Type of fuseDIN
Type of disconnectorSwitch-disconnector-fuse
Contact position indicationPositive contact position indication
MountingPanel mounting
Type of Dilos/FulosFULOS 2
400/415V (AC23A/AC23B)400 A
500V (AC23A/AC23B)400 A
690V (AC23A/AC23B)300 A
400/415V (AC22A/AC22B)400 A
500V (AC22A/AC22B)400 A
690V (AC22A/AC22B)400 A
400/415V (AC21A/AC21B)400 A
500V (AC21A/AC21B)400 A
690V (AC21A/AC21B)400 A
110V (DC23A 2P)400 A
250V (DC23A 4P)400 A
Rated operational voltage Ue (V)690 V
Rated impulse withstand voltage (2000 m) Uimp8 kV
StandardsBS88part21988;BSNBNEN60947-3;CEI17-11(Fasc.1039);DINVDE0636Teil1;DINVDE0660Teil1;IEC60269-2-1;IEC60947-1;IEC60947-3;K63B;NBNEN60947-3;NFC63-210;NFC63130;NFC63211;NFEN60269-1
ApprovalsKEMA
Conventional enclosed thermal current lthe400 A
Maximum torque on terminals (Nm)60 Nm
Rated insulation voltage Ui (V)1000 V
Durability (number of operational cycles) electrical700
Max Rated Operational Power 400/415V (AC23 (kW))218 kW/230 kW
Max Rated Operational Power 500V (AC23 (kW))295 kW
Max Rated Operational Power 690V (AC23 (kW))290 kW
Rated capacity power at 400V (kVAR)19 kVAr
Terminal capacity (Cu-rail mm x mm)Cu-rail 2x40x6 mm
Durability (number of operational cycles) mech. (min.)5000
Rated Cond S/C current Backup protection kA rms @ 400V100 kA
Rated Cond S/C current Backup protection kA rms @ 415V100 kA
Rated Cond S/C current Backup protection kA rms @ 500V100 kA
Rated Cond S/C current Backup protection kA rms @ 690V100 kA

DIMENSIONS

Weight10.6 kg

CLASSIFICATION

ETIM 5.0EC001040
ETIM 6.0EC001040

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review