730833 GENERAL ELECTRIC Switch-disconnector-fuse Fulos 000 NF 22 x 58 100A 3P+N View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

730833 GENERAL ELECTRIC Switch-disconnector-fuse Fulos 000 NF 22 x 58 100A 3P+N

730833

GENERAL ELECTRIC

Available

Ship on today

Switch-disconnector-fuse Fulos 000 NF 22 x 58 100A 3P+N

More details


Residual Current Devices Rcd Ground Fault Circuit Interrupter Gfci Breaker Rccb

Industrial

DIFFERENTIAL PROTECTION

* Brand new product in its original packaging covered by the warranties and certifications provided by GENERAL ELECTRIC

Quantity Price
1+$171.66
2+$164.64
3+$161.35
4+$159.32
6+$156.93
*This price is per unit and is the net value (not including taxes if applicable).

Related products

More info



Fulos 000 NF - 125A

Performance

  • Panel mounting
  • Fused-safety-switch-disconnector (main disconnector)
  • Disconnect function
  • Transparent cover
  • Quick make and quick break mechanism
  • Independent opening and closing
  • Positive contact indication (PCI)
  • Very low power losses
  • Fuse completely disconnected in "OFF"
  • Defeat mechanism rotary handle
  • Double knife contacts - high short-circuit resistance
  • Number of poles 3P - 4P

Standards
  • For disconnectors
    IEC 60947-1 and IEC 60947-3, DIN VDE 0660 Teil 107, BS EN 60947-3, CEI 17-11 (Fasc. 1039), EN 60947-3, NBN EN 60947-3, NF C 63-130
    Safety-switch-disconnector (red/yellow) according to DIN VDE 0113 Teil 1
  • For fuses
    IEC 60269-2-1, BS 88 Parts 1 & 2 1988, DIN VDE 0636 Teil 1,NF EN 60269-1, NF C 63-211, NF C 63-210

SPECIFICATIONS

SeriesSwitch-disconnector-fuses - FULOS
Conventional enclosed thermal current Ithe = Ith100 A;63 A
Number of poles4P
Type of fuseNF
Type of disconnectorSwitch-disconnector-fuse
Contact position indicationPositive contact position indication
MountingPanel mounting
Type of Dilos/FulosFULOS 000
400/415V (AC23A/AC23B)125 A
500V (AC23A/AC23B)100 A
690V (AC23A/AC23B)80 A
400/415V (AC22A/AC22B)125 A
500V (AC22A/AC22B)125 A
690V (AC22A/AC22B)125 A
400/415V (AC21A/AC21B)125 A
500V (AC21A/AC21B)125 A
690V (AC21A/AC21B)125 A
110V (DC23A 2P)100 A
250V (DC23A 2P)63 A
250V (DC23A 4P)100 A
Rated operational voltage Ue (V)690 V
Rated impulse withstand voltage (2000 m) Uimp8 kV
StandardsBS88part21988;BSNBNEN60947-3;CEI17-11(Fasc.1039);DINVDE0636Teil1;DINVDE0660Teil1;IEC60269-2-1;IEC60947-1;IEC60947-3;K63B;NBNEN60947-3;NFC63-210;NFC63130;NFC63211;NFEN60269-1
ApprovalsKEMA
Conventional enclosed thermal current lthe125 A
Maximum torque on terminals (Nm)12 Nm
Rated insulation voltage Ui (V)1000 V
Durability (number of operational cycles) electrical3000
Max Rated Operational Power 400/415V (AC23 (kW))69 kW/72 kW
Max Rated Operational Power 500V (AC23 (kW))86 kW
Max Rated Operational Power 690V (AC23 (kW))45 kW
Rated capacity power at 400V (kVAR)60 kVAr
Durability (number of operational cycles) mech. (min.)10000
Terminal capacity (Cu) min/max (mm²)6 mm²/50 mm²
Rated Cond S/C current Backup protection kA rms @ 400V50 kA
Rated Cond S/C current Backup protection kA rms @ 415V50 kA
Rated Cond S/C current Backup protection kA rms @ 500V50 kA
Rated Cond S/C current Backup protection kA rms @ 690V33 kA

DIMENSIONS

Weight1.27 kg

CLASSIFICATION

ETIM 5.0 EC001040
ETIM 6.0 EC001040

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

Latest Customer Reviews

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.