730988 GENERAL ELECTRIC Switch-disconnector Dilos 00 32A 3P DIN-rail View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

730988 GENERAL ELECTRIC Switch-disconnector Dilos 00 32A 3P DIN-rail

730988

GENERAL ELECTRIC

Available

Ship on today

Switch-disconnector Dilos 00 32A 3P DIN-rail

More details


Residual Current Devices Rcd Ground Fault Circuit Interrupter Gfci Breaker Rccb

Industrial

DIFFERENTIAL PROTECTION

* Brand new product in its original packaging covered by the warranties and certifications provided by GENERAL ELECTRIC

Quantity Price
1+$34.23
9+$29.64
17+$28.67
25+$28.20
34+$27.89
*This price is per unit and is the net value (not including taxes if applicable).

Related products

More info



Dilos 00 - 16A up to 40A

Performance

  • DIN-rail type
  • Disconnect function
  • Complete range of add-on devices
  • Double knife contacts
  • Number of poles 2P - 3P - 4P
  • Mounting
    • DIN-rail / Panel
    • Wall
  • Box terminals
  • Padlockable

Standards

IEC 60947-1 and IEC 60947-3, DIN VDE 0660 Teil 107,BS EN 60947-3, CEI 17-11 (Fasc. 1039), EN 60947-3, NBN EN 60947-3, NF C 63-130 Safety-switch-disconnector (red/yellow) according to DIN VDE 0113 Teil 1

SPECIFICATIONS

SeriesSwitch-disconnectors - DILOS
Conventional enclosed thermal current Ithe = Ith32 A
Number of poles3P
Type of disconnectorSwitch-disconnector
Contact position indicationPositive contact position indication
MountingDIN-rail
Type of Dilos/FulosDILOS 00
400/415V (AC23A/AC23B)32 A
500V (AC23A/AC23B)32 A
690V (AC23A/AC23B)25 A
400/415V (AC22A/AC22B)32 A
500V (AC22A/AC22B)32 A
690V (AC22A/AC22B)32 A
400/415V (AC21A/AC21B)32 A
500V (AC21A/AC21B)32 A
690V (AC21A/AC21B)32 A
110V (DC23A 2P)32 A
250V (DC23A 4P)32 A
Rated operational voltage Ue (V)690 V
Rated impulse withstand voltage (2000 m) Uimp8 kV
StandardsBSNBNEN60947-3;CEI17-11(Fasc.1039);DINVDE0660Teil1;IEC60947-1;IEC60947-3;K63B;NBNEN60947-3;NFC63130
ApprovalsKEMA
Conventional enclosed thermal current lthe32 A
Maximum torque on terminals (Nm)2.2 Nm
Rated insulation voltage Ui (V)690 V
Durability (number of operational cycles) electrical3000
Max Rated Operational Power 400/415V (AC23 (kW))11 kW/11 kW
Max Rated Operational Power 500V (AC23 (kW))11 kW
Max Rated Operational Power 690V (AC23 (kW))11 kW
Rated short circuit making cap Icm (kA peak) Ue = 400V4.5 kA
Rated short circuit making cap Icm (kA peak) Ue = 415V4.5 kA
Rated short circuit making cap Icm (kA peak) Ue = 500V3 kA
Rated short circuit making cap Icm (kA peak) Ue = 690V3 kA
Rated short time withstand current Icw (kA rms) 1 s1.2 kA
Durability (number of operational cycles) mech. (min.)40000
Terminal capacity (Cu) min/max (mm²)1.5 mm²/16 mm²
Rated Cond S/C current Backup protection kA rms @ 400V50 kA
Rated Cond S/C current Backup protection kA rms @ 415V50 kA
Rated Cond S/C current Backup protection kA rms @ 500V50 kA
Rated Cond S/C current Backup protection kA rms @ 690V50 kA

DIMENSIONS

Weight0.125 kg

CLASSIFICATION

ETIM 5.0 EC000216
ETIM 6.0 EC000216

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

Latest Customer Reviews

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.