Dilos 00 - 16A up to 40A

Performance

  • DIN-rail type
  • Disconnect function
  • Complete range of add-on devices
  • Double knife contacts
  • Number of poles 2P - 3P - 4P
  • Mounting
    • DIN-rail / Panel
    • Wall
  • Box terminals
  • Padlockable

Standards

IEC 60947-1 and IEC 60947-3, DIN VDE 0660 Teil 107,BS EN 60947-3, CEI 17-11 (Fasc. 1039), EN 60947-3, NBN EN 60947-3, NF C 63-130 Safety-switch-disconnector (red/yellow) according to DIN VDE 0113 Teil 1

SPECIFICATIONS

SeriesSwitch-disconnectors - DILOS
Conventional enclosed thermal current Ithe = Ith32 A
Number of poles3P
Type of disconnectorSwitch-disconnector
Contact position indicationPositive contact position indication
MountingDIN-rail
Type of Dilos/FulosDILOS 00
400/415V (AC23A/AC23B)32 A
500V (AC23A/AC23B)32 A
690V (AC23A/AC23B)25 A
400/415V (AC22A/AC22B)32 A
500V (AC22A/AC22B)32 A
690V (AC22A/AC22B)32 A
400/415V (AC21A/AC21B)32 A
500V (AC21A/AC21B)32 A
690V (AC21A/AC21B)32 A
110V (DC23A 2P)32 A
250V (DC23A 4P)32 A
Rated operational voltage Ue (V)690 V
Rated impulse withstand voltage (2000 m) Uimp8 kV
StandardsBSNBNEN60947-3;CEI17-11(Fasc.1039);DINVDE0660Teil1;IEC60947-1;IEC60947-3;K63B;NBNEN60947-3;NFC63130
ApprovalsKEMA
Conventional enclosed thermal current lthe32 A
Maximum torque on terminals (Nm)2.2 Nm
Rated insulation voltage Ui (V)690 V
Durability (number of operational cycles) electrical3000
Max Rated Operational Power 400/415V (AC23 (kW))11 kW/11 kW
Max Rated Operational Power 500V (AC23 (kW))11 kW
Max Rated Operational Power 690V (AC23 (kW))11 kW
Rated short circuit making cap Icm (kA peak) Ue = 400V4.5 kA
Rated short circuit making cap Icm (kA peak) Ue = 415V4.5 kA
Rated short circuit making cap Icm (kA peak) Ue = 500V3 kA
Rated short circuit making cap Icm (kA peak) Ue = 690V3 kA
Rated short time withstand current Icw (kA rms) 1 s1.2 kA
Durability (number of operational cycles) mech. (min.)40000
Terminal capacity (Cu) min/max (mm²)1.5 mm²/16 mm²
Rated Cond S/C current Backup protection kA rms @ 400V50 kA
Rated Cond S/C current Backup protection kA rms @ 415V50 kA
Rated Cond S/C current Backup protection kA rms @ 500V50 kA
Rated Cond S/C current Backup protection kA rms @ 690V50 kA

DIMENSIONS

Weight0.125 kg

CLASSIFICATION

ETIM 5.0 EC000216
ETIM 6.0 EC000216

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

Últimas Opiniones de Nuestros Clientes

Todas las valoraciones que recibimos de los artículos que ofrecemos son reales y están verificadas. Un pequeño gesto, pero de mucho valor. Por eso, te agradecemos ese minuto que inviertes en dejarnos tu opinión y calificación sobre los productos, porque nos ayuda a seguir mejorando y a ofrecerte un servicio de todavía mayor calidad.