FGQDB3H/6 431163 GENERAL ELECTRIC FG-RCD DiffBottom-3p 400-690V View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

FGQDB3H/6 431163 GENERAL ELECTRIC FG-RCD DiffBottom-3p 400-690V

FGQDB3H/6

431163

GENERAL ELECTRIC

FG-RCD DiffBottom-3p 400-690V

More details


Industrial > DIFFERENTIAL PROTECTION

* Brand new product in its original packaging covered by the warranties and certifications provided by GENERAL ELECTRIC

* This article may be obsolete. Ask for a quotation and we will check if there are any units available. If not, one of our technicians will look for an alternative solution.

If our price is not the best, please ask us for a quote. Ask for a quotation

Best sellers

More info



A record plus circuit breaker can offer protection against earth leakage currents by using an add-on residual current device (RCD). A line of three pole completely integrated add-on devices are available as side mounted models (FD frame size) or as units that are fitted below the trip unit of the breaker (FD, FE and FG frame sizes). In all cases the RCD unit interfaces directly with the circuit breaker without the use of any secondary wiring connections. Earth RCD has a sensor placed around the phase and neutral current paths that detects the vectorial sum of the phase and neutral currents. When this sum is no longer zero it is assumed that current is flowing to earth (residual current). If this value exceeds the threshold set on the RCD the breaker connected to the device is tripped.
The RCD units electrical power is supplied by the line voltage of the breaker it is linked to. By use of a multi-phase bridge the design still works when one phase and the neutral is present. A pouch on the RCD allows one to place one BAT contact NO or NC which allows a remote signal on earth faults. A Record Plus breaker and an RCD combination can be connected like any stand-alone breaker and are available as fixed or plug-in devices. The mains connection interface of the RCD is an exact replica of the breaker connection area, thus allowing the use of all standard breaker terminals.

ORDER/DELIVERY STATUS

Status Active

SPECIFICATIONS

SeriesResidual Current devices
RangeProtection
Number of poles3P
Frame typeG frame (400A/630A)
Accessory DetailDifferential bottom
Measurements109x138.7x125.4 mm
Standard packing1

DIMENSIONS

Weight5 kg

CLASSIFICATION

ETIM 5.0 EC001021
ETIM 6.0 EC001021

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.