Z-R23/16-01 ICS-R16D024B010 4100207 EATON ELECTRIC Installation relay, 24 V DC, 1NC, 16A View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

Z-R23/16-01 ICS-R16D024B010 4100207 EATON ELECTRIC Installation relay, 24 V DC, 1NC, 16A

Z-R23/16-01

ICS-R16D024B010

4100207

EATON-MOELLER

2

Installation relay, 24 V DC, 1NC, 16A

Contactor modular, 24 vdc, 1NC, 16A, 1ΜM

More details


Modular Switchgear – Others and Accessories

* Brand new product in its original packaging covered by the warranties and certifications provided by EATON-MOELLER

* This article may be obsolete. Ask for a quotation and we will check if there are any units available. If not, one of our technicians will look for an alternative solution.

If our price is not the best, please ask us for a quote. Ask for a quotation

Best sellers

More info



Installation relay, 24 V DC, 1NC, 16A
Installation relay with manual operation, control voltage 24V DC, function: 1 NC, rated operational current 16 A, 240V AC, type conform to IEC/EN 60947-4-1, standard front dimension 45 mm, mounting width 1 MU top-hat rail mounting.

Design verification as per IEC/EN 61439

Technical data for design verification
Rated operational current for specified heat dissipation [In]
16 A
Equipment heat dissipation, current-dependent [Pvid]
0.8 W
IEC/EN 61439 design verification
10.2 Strength of materials and parts10.2.2 Corrosion resistance
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.5 Lifting
Does not apply, since the entire switchgear needs to be evaluated.
10.2 Strength of materials and parts10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.2 Strength of materials and parts10.2.7 Inscriptions
Meets the product standard's requirements.
10.3 Degree of protection of ASSEMBLIES
Does not apply, since the entire switchgear needs to be evaluated.
10.4 Clearances and creepage distances
Meets the product standard's requirements.
10.5 Protection against electric shock
Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components
Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections
Is the panel builder's responsibility.
10.8 Connections for external conductors
Is the panel builder's responsibility.
10.9 Insulation properties10.9.2 Power-frequency electric strength
Is the panel builder's responsibility.
10.9 Insulation properties10.9.3 Impulse withstand voltage
Is the panel builder's responsibility.
10.9 Insulation properties10.9.4 Testing of enclosures made of insulating material
Is the panel builder's responsibility.
10.10 Temperature rise
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.12 Electromagnetic compatibility
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.13 Mechanical function
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.

Technical data ETIM 6.0

Devices for distribution board-/surface mounting (EG000062) / Installation relay (EC001652)
Electric engineering, automation, process control engineering / Electrical installation, device / Modular serial built-in device for electrical circuit distributors / Installation relay for distribution board ([email protected] [AFZ821011])
Function
Mechanical
Mounting method
DIN rail
Width in number of modular spacings
1
Built-in depth
60 mm
Number of normally open contacts
0
Number of normally closed contacts
1
Number of change-over contacts
0
Control voltage 1
21 - 26 V
Type of control voltage 1
DC
Frequency control voltage 1
0 - 0 Hz
Control voltage 2
0 - 0 V
Type of control voltage 2
DC
Frequency control voltage 2
0 - 0 Hz
Nominal rated current
16 A
Supply voltage
240 - 240 V
Voltage type of supply voltage
AC
Max. incandescent lamp load
720 W
Max. load fluorescent lamp
303 VA
Max. load fluorescent lamp (Duo circuit)
541 VA
Max. load fluorescent lamp (parallel compensated)
271 VA
Max. switching current (cos phi = 0.6)
5 A

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.