Product successfully added to your shopping cart
XSDMC-2004
193281
Y7-193281
EATON-MOELLER
1
Variable frequency drive, 500 V AC, 3-phase, 13.5 A, 7.5 kW, IP21/NEMA1, Brake chopper, DC link choke
XSDMC-2004
Door to switchgear area, closed, IP55, HxW=500x425mm
Cabinet enclosures > Door/operating panel (switchgear cabinet)
Enclosures
Brand new product in its original packaging covered by the warranties and certifications provided by EATON-MOELLER
Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
Product range | Variable frequency drives | ||
Part group reference (e.g. DIL) | DG1 | ||
Rated operational voltage | Ue | 600 V AC, 3-phase | |
Output voltage with Ve | U2 | 600 V AC, 3-phase | |
Mains voltage (50/60Hz) | ULN | V | 500 (-10%) - 600 (+10%) |
Rated operational current | |||
At 150% overload | Ie | A | 13.5 |
At 110% overload | Ie | A | 18 |
Note | Rated operational current for a switching frequency of 1 - 6 kHz and an ambient temperature of +50 °C for a 150% overload and +40 °C for a 110% overload | ||
Assigned motor rating | |||
Note | for normal internally and externally ventilated 4 pole, three-phase asynchronous motors with 1500 rpm-1at 50 Hz or 1800 min-1at 60 Hz | ||
Note | Overload cycle for 60 s every 600 s | ||
Note | at 525 V, 50 Hz | ||
150 % Overload | P | kW | 7.5 |
110 % Overload | P | kW | 11 |
150 % Overload | IM | A | 12.1 |
110 % Overload | IM | A | 17.4 |
Note | at 600 V, 50 Hz | ||
150 % Overload | P | kW | 7.5 |
110 % Overload | P | kW | 11 |
150 % Overload | IM | A | 10.6 |
110 % Overload | IM | A | 15.1 |
Note | at 600 V, 60 Hz | ||
150 % Overload | P | HP | 10 |
110 % Overload | P | HP | 15 |
150 % Overload | IM | A | 11 |
110 % Overload | IM | A | 17 |
Degree of Protection | IP21/NEMA1 | ||
Interface/field bus (built-in) | Modbus RTU Modbus TCP BACnet MS/TP Ethernet IP | ||
Fieldbus connection (optional) | PROFIBUS CANopen® DeviceNet SmartWire-DT | ||
Fitted with | Radio interference suppression filter Additional PCB protection Multi-line graphic display Brake chopper DC link choke | ||
Frame size | FS2 | ||
Connection to SmartWire-DT | yes in conjunction with DXG-NET-SWD SmartWire DT module |
| General | |||
Standards | Specification for general requirements: IEC/EN 61800-2 EMC requirements: IEC/EN 61800-3 Safety requirements: IEC/EN 61800-5 | ||
Certifications | CE, UL, cUL, c-Tick, UkrSEPRO, EAC | ||
Production quality | RoHS, ISO 9001 | ||
Climatic proofing | ρw | % | < 95%, average relative humidity (RH), non-condensing, non-corrosive |
Air quality | 3C2, 3S2 | ||
Ambient temperature | |||
operation (150 % overload) | ϑ | °C | -30 - +50 (max. +60 with 1 % derating per Kelvin temperature rise) |
operation (110 % overload) | ϑ | °C | -30 - +40 (max. +55 mit 1 % Derating pro Kelvin Temperaturerhöhung) |
Storage | ϑ | °C | -40 - +70 |
Overvoltage category | III | ||
Pollution degree | 2 | ||
Radio interference level | |||
Radio interference class (EMC) | C1 (with external filter, for conducted emissions only), C2, C3, depending on the motor cable length, the connected load, and ambient conditions. External radio interference suppression filters (optional) may be necessary. | ||
Environment (EMC) | 1st and 2nd environments as per EN 61800-3 | ||
maximum motor cable length | I | m | C3 ≤ 10 m |
Mechanical shock resistance | g | EN 61800-5-1, EN 60068-2-27 UPS drop test (for weights inside the UPS frame) Storage and transportation: maximum 15 g, 11 ms (inside the packaging) | |
Vibration | EN 61800-5-1, EN 60068-2-6: 5 - 150 Hz Amplitude: 1 mm (peak) at 5 - 15.8 Hz Maximum acceleration amplitude: 1 g at 15.8 – 150 Hz | ||
Mounting position | Vertical | ||
Altitude | m | 0 - 1000 m above sea level Above 1000 m: 1% derating for every 100 m max. 2000 m | |
Degree of Protection | IP21/NEMA1 | ||
Protection against direct contact | BGV A3 (VBG4, finger- and back-of-hand proof) | ||
| Main circuit | |||
Supply | |||
Rated operational voltage | Ue | 600 V AC, 3-phase | |
Mains voltage (50/60Hz) | ULN | V | 500 (-10%) - 600 (+10%) |
Input current (150% overload) | ILN | A | 12.5 |
Input current (110% overload) | ILN | T | 16.7 |
System configuration | TN-S, TN-C, TN-C-S, TT, IT | ||
Supply frequency | fLN | Hz | 50/60 |
Frequency range | fLN | Hz | 45 - 66 |
Mains switch-on frequency | Maximum of one time every 60 seconds | ||
Mains current distortion | THD | % | 36.7 |
Rated conditional short-circuit current | Iq | kA | < 100 |
Power section | |||
Function | Variable frequency drive with internal DC link, DC link choke and IGBT inverter | ||
Overload current (150% overload) | IL | A | 20.25 |
Overload current (110% overload) | IL | A | 19.8 |
max. starting current (High Overload) | IH | % | 200 |
Note about max. starting current | for 2 seconds every 20 seconds | ||
Output voltage with Ve | U2 | 600 V AC, 3-phase | |
Output Frequency | f2 | Hz | 0 - 50/60 (max. 400) |
Switching frequency | fPWM | kHz | 1.5 adjustable 1 - 6 |
Operation Mode | U/f control Speed control with slip compensation sensorless vector control (SLV) Torque regulation | ||
Frequency resolution (setpoint value) | Δf | Hz | 0.01 |
Rated operational current | |||
At 150% overload | Ie | A | 13.5 |
At 110% overload | Ie | A | 18 |
Note | Rated operational current for a switching frequency of 1 - 6 kHz and an ambient temperature of +50 °C for a 150% overload and +40 °C for a 110% overload | ||
Motor current limit | I | A | 0.1 - 2 x IH(CT) |
Power loss | |||
Heat dissipation at rated operational current Ie=150 % | PV | W | 221 |
Heat dissipation at rated operational current Ie=110% | PV | W | 303 |
Efficiency | η | % | 98.2 |
Maximum leakage current to ground (PE) without motor | IPE | mA | 9.8 |
Fan | temperature controlled Tool-less swapping | ||
Internal fan delivery rate | m3/h | 94 | |
Fitted with | Radio interference suppression filter Additional PCB protection Multi-line graphic display Brake chopper DC link choke | ||
Safety function | STO (Safe Torque Off, SIL1, PLc Cat 1) | ||
Frame size | FS2 | ||
Motor feeder | |||
Note | for normal internally and externally ventilated 4 pole, three-phase asynchronous motors with 1500 rpm-1at 50 Hz or 1800 min-1at 60 Hz | ||
Note | Overload cycle for 60 s every 600 s | ||
Note | at 525 V, 50 Hz | ||
150 % Overload | P | kW | 7.5 |
110 % Overload | P | kW | 11 |
Note | at 600 V, 50 Hz | ||
150 % Overload | P | kW | 7.5 |
110 % Overload | P | kW | 11 |
Note | at 600 V, 60 Hz | ||
150 % Overload | P | HP | 10 |
110 % Overload | P | HP | 15 |
maximum permissible cable length | I | m | screened: 150 |
Apparent power | |||
Apparent power at rated operation 600 V | S | kVA | 18.7 |
Braking function | |||
Standard braking torque | max. 30 % MN | ||
DC braking torque | adjustable to 150 % | ||
Braking torque with external braking resistance | Max. 100% of rated operational current Iewith external braking resistor | ||
minimum external braking resistance | Rmin | Ω | 30 |
Switch-on threshold for the braking transistor | UDC | V | Supply voltage UAUX 1050 V DC |
DC braking | % | I/Ie | ≦ 150, adjustable |
| Control section | |||
External control voltage | Uc | V | 24 V DC (max. 250 mA options incl.) |
Reference voltage | Us | V | 10 V DC (max. 10 mA) |
Analog inputs | 2, parameterizable, 0 - 10 V DC, 2 - 10 V DC, -10 - +10 V DC, 0/4 - 20 mA | ||
Analog outputs | 2, parameterizable, 0 - 10 V, 0/4 - 20 mA | ||
Digital inputs | 8, parameterizable, max. 30 V DC | ||
Digital outputs | 1, parameterizable, 24 V DC | ||
Relay outputs | 3, parameterizable, 2 changeover contacts and 1 N/O, 6 A (240 VAC) / 6 A (24 VDC) | ||
Interface/field bus (built-in) | Modbus RTU Modbus TCP BACnet MS/TP Ethernet IP | ||
Expansion slots | 2 | ||
| Assigned switching and protective elements | |||
Power Wiring | |||
Safety device (fuse or miniature circuit-breaker) | |||
IEC (Type B, gG), 150 % | PKZM0-16 | ||
IEC (Type B, gG), 110 % | PKZM0-20 | ||
UL (Class CC or J) | A | 30 | |
Mains contactor | |||
150 % overload (CT/IH, at 50 °C) | DILM7 | ||
110 % overload (VT/IL, at 40 °C) | DILM7 | ||
Main choke | |||
150 % overload (CT/IH, at 50 °C) | Integrated DC link choke, uk = 5% | ||
110 % overload (VT/IL, at 40 °C) | Integrated DC link choke, uk = 5% | ||
Note regarding radio interference suppression filter | Optional external radio interference suppression filter for longer motor cable lengths and for use in different EMC environments | ||
DC link connection | |||
Braking resistance | |||
10 % duty factor (DF) | DX-BR040-3K1 | ||
20 % duty factor (DF) | DX-BR040-5K1 | ||
40 % duty factor (DF) | DX-BR047-9K2 | ||
Notes concerning braking resistances: | PnRm: = Connect every "n" resistors in parallel, then connect the resulting combinations "m" times in series. A total of "n" x "m" resistors will be needed. | ||
Motor feeder | |||
motor choke | |||
150 % overload (CT/IH, at 50 °C) | DX-LM3-016 | ||
110 % overload (VT/IL, at 40 °C) | DX-LM3-035 | ||
Sine filter | |||
150 % overload (CT/IH, at 50 °C) | DX-SIN3-016 | ||
110 % overload (VT/IL, at 40 °C) | DX-SIN3-023 | ||
All-pole sine filter | |||
150 % overload (CT/IH, at 50 °C) | DX-SIN3-024-A | ||
110 % overload (VT/IL, at 40 °C) | DX-SIN3-024-A | ||
| Product Standards | UL508C, CSA-C22.2 No. 274-13; IEC/EN61800-3; IEC/EN61800-5; CE marking | ||
| UL File No. | E134360 | ||
| UL Category Control No. | NMMS, NMMS7 | ||
| CSA File No. | UL report applies to both US and Canada | ||
| North America Certification | UL listed, certified by UL for use in Canada | ||
| Suitable for | Branch circuits | ||
| Max. Voltage Rating | 3~600 V AC IEC: TN-S UL/CSA: 'Y' (Solidly Grounded Wey) | ||
| Degree of Protection | IP21/NEMA1 |
| Low-voltage industrial components (EG000017) / Frequency converter =< 1 kV (EC001857) | |||
| Electric engineering, automation, process control engineering / Electrical drive / Static frequency converter / Static frequency converter = < 1 kV ([email protected] [AKE177014]) | |||
Mains voltage | V | 525 - 600 | |
Mains frequency | 50/60 Hz | ||
Number of phases input | 3 | ||
Number of phases output | 3 | ||
Max. output frequency | Hz | 400 | |
Max. output voltage | V | 575 | |
Nominal output current I2N | A | 13.5 | |
Max. output at quadratic load at rated output voltage | kW | 11 | |
Max. output at linear load at rated output voltage | kW | 15 | |
Relative symmetric net frequency tolerance | % | 10 | |
Relative symmetric net voltage tolerance | % | 10 | |
Number of analogue outputs | |||
Number of analogue inputs | |||
Number of digital outputs | |||
Number of digital inputs | |||
With control unit | Yes | ||
Application in industrial area permitted | Yes | ||
Application in domestic- and commercial area permitted | Yes | ||
Supporting protocol for TCP/IP | Yes | ||
Supporting protocol for PROFIBUS | Yes | ||
Supporting protocol for CAN | Yes | ||
Supporting protocol for INTERBUS | No | ||
Supporting protocol for ASI | No | ||
Supporting protocol for KNX | No | ||
Supporting protocol for MODBUS | Yes | ||
Supporting protocol for Data-Highway | No | ||
Supporting protocol for DeviceNet | Yes | ||
Supporting protocol for SUCONET | No | ||
Supporting protocol for LON | No | ||
Supporting protocol for PROFINET IO | Yes | ||
Supporting protocol for PROFINET CBA | No | ||
Supporting protocol for SERCOS | No | ||
Supporting protocol for Foundation Fieldbus | No | ||
Supporting protocol for EtherNet/IP | No | ||
Supporting protocol for AS-Interface Safety at Work | No | ||
Supporting protocol for DeviceNet Safety | No | ||
Supporting protocol for INTERBUS-Safety | No | ||
Supporting protocol for PROFIsafe | No | ||
Supporting protocol for SafetyBUS p | No | ||
Supporting protocol for BACnet | |||
Supporting protocol for other bus systems | Yes | ||
Number of HW-interfaces industrial Ethernet | 1 | ||
Number of interfaces PROFINET | 1 | ||
Number of HW-interfaces RS-232 | 0 | ||
Number of HW-interfaces RS-422 | 0 | ||
Number of HW-interfaces RS-485 | 1 | ||
Number of HW-interfaces serial TTY | 0 | ||
Number of HW-interfaces USB | 0 | ||
Number of HW-interfaces parallel | 0 | ||
Number of HW-interfaces other | 1 | ||
With optical interface | No | ||
With PC connection | Yes | ||
Integrated breaking resistance | Yes | ||
4-quadrant operation possible | Yes | ||
Type of converter | U converter | ||
Degree of protection (IP) | IP21 | ||
Degree of protection (NEMA) | |||
Height | mm | 419 | |
Width | mm | 169 | |
Depth | mm | 244 | |
| Feature Name | Feature Value |
|---|---|
| Model (EF000010) | Other |
| Version as glazed door (EF006966) | No |
| Version as door for disconnecting switch interlocking (EF006967) | No |
| Width (EF000008) | 595 mm |
| Height (EF000040) | 497 mm |
| Depth (EF000049) | 82 mm |
| EMC-version (EF001062) | No |
| Material (EF002169) | Other |
| Surface finishing (EF006569) | Powder coated |
| Colour (EF000007) | Grey |
| Degree of protection (IP) (EF005474) | IP55 |
| Title: | Size: | Type: |
|---|---|---|
| PDF CATALOGUE EATON EN .pdf | 38 Mbytes |
|
| XSDMC-2004 Y7-193281 193281 193281_EN.pdf | 229 Kbytes |
![]() |
No customer reviews for the moment.
| Rating: |
|
| Name: | |
| Email: | |
| Subject: | |
| Text: | |
| Do you recommend this product to buy? | |
|
|
|
| Add review | |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.