XN-322-8AIO-I 178771 EATON ELECTRIC Analog input and output module 4 analog inputs and 4 analog outputs 0/4 .. View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

XN-322-8AIO-I 178771 EATON ELECTRIC Analog input and output module 4 analog inputs and 4 analog outputs 0/4 ..

XN-322-8AIO-I

178771

EATON-MOELLER

Analog input and output module; 4 analog inputs and 4 analog outputs; 0/4 to 20 mA

XN-322-8AIO-I

More details


PLC's > Fieldbus, decentr. periphery - analogue I/O module

Remote I / O Modules XN300

* Brand new product in its original packaging covered by the warranties and certifications provided by EATON-MOELLER

Total price: $335.00
Unit price: $335.00

Quantity Price
1+$335.00
2+$324.53
*This price is per unit and is the net value (not including taxes if applicable).

If our price is not the best, please ask us for a quote. Ask for a quotation

More info



General specifications

Product Name
Eaton XN-322 I/O module
Catalog Number
178771
Model Code
XN-322-8AIO-I
EAN
7640130098350
Product Length/Depth
104.2 mm
Product Height
16.8 mm
Product Width
80.3 mm
Product Weight
0.061 kg
Certifications
IEC/EN 61131-2
IEC/EN 61000-6-4
IEC/EN 61000-6-2
CE
CULus
UL File No.: E135462
Catalog Notes
The max. heat dissipation is specified as the maximum power produced inside the device's housing.

Features & Functions

Current measurement
50 Ω typ., input resistance
0 - 20 mA
Electric connection type
Plug-in connection
Features
Analog outputs configurable
Input, current
Output, current
Analog inputs configurable
Fieldbus connection over separate bus coupler possible
Input signal, configurable
Fitted with:
Parameterizable Software input filter
1 kHz, third-order low-pass input filter
Value representation
SIGNED16, Current measurement

General

Current consumption
55 mA (typ.), for +5 V power supply (internal), Power supply - Input
None mA (typ.), for +24 V, Power supply - Input
Degree of protection
IP20
NEMA 1
Limit frequency
1 kHz (third-order low-pass filter)
Mounting method
Rail mounting possible
Number of channels
4, Analog Inputs
Overvoltage category
III
Pollution degree
3
Product category
XN-322 analog input and output module
Resolution
  • 12 Bit (Analog outputs)
  • 16 Bit (Analog inputs)
Type
  • Analog mixed module with 4 analog outputs 0/4 to 20 mA (12 bit) and 4 analog inputs 0/4 to 20 mA (16 bit).
  • XN300 I/O slice module
Used with
XN300
XN-312-…
Voltage type
DC

Ambient conditions, mechanical

Height of fall (IEC/EN 60068-2-32) - max
1 m
Mounting position
Horizontal
Shock resistance
15 g, Mechanical, Half-sinusoidal shock 11 ms, 18 Impacts
Vibration resistance
5 - 8.4 / 8.4 -150 Hz, 3,5 mm / 1 g

Climatic environmental conditions

Air pressure
795 - 1080 hPa (operation)
Ambient operating temperature - min
0 °C
Ambient operating temperature - max
60 °C
Ambient storage temperature - min
-20 °C
Ambient storage temperature - max
85 °C
Climatic proofing
Damp heat, constant, to IEC 60068-2-3
Dry heat to IEC 60068-2-2
Environmental conditions
Condensation: prevent with appropriate measures
Relative humidity
0 - 95 % (non-condensing)

Electro magnetic compatibility

Air discharge
8 kV
Burst impulse
2 kV, Supply cable
1 kV, Signal cable
Contact discharge
4 kV
Electromagnetic fields
1 V/m at 2 - 2.7 GHz (according to IEC EN 61000-4-3)
10 V/m at 0.08 - 1.0 GHz (according to IEC EN 61000-4-3)
3 V/m at 1.4 - 2 GHz (according to IEC EN 61000-4-3)
Emitted interference
47 dB (at 230 - 1000 MHz, Class A, radiated, high frequency)
40 dB (at 30 - 230 MHz, Class A, radiated, high frequency)
Radiated RFI
10 V
Surge rating
1 kV, Signal cable, unbalanced, EMC
0.5/0.5 kV, Supply cable, balanced/unbalanced), EMC
Voltage dips
Voltage dips: 10 ms/Voltage fluctuations: Yes

Terminal capacities

Terminal capacity
24 - 16 AWG
0.2 - 1.5 mm², flexible without ferrule, H07V-K
0.25 - 1.5 mm², with ferrules with plastic collar according to DIN 46228-1 (ferrules crimped gas-tight)
0.25 - 1.5 mm², with ferrules without plastic collar according to DIN 46228-1 (ferrules crimped gas-tight)
0.2 - 1.5 mm², solid, H07V-U
Gauge pin
A1 (according to IEC/EN 60947-1)
Stripping length (main cable)
10 mm
Insulating material group
I

Electrical rating

Rated operational voltage
24 V (X5)
160 V (terminations)
Short-circuit protection
Yes, Short-circuit strength, Analog outputs
Supply voltage at AC, 50 Hz - min
0 VAC
Supply voltage at AC, 50 Hz - max
0 VAC
Supply voltage at DC - min
18 VDC
Supply voltage at DC - max
30 VDC

Communication

Connection type
Push-in spring-cage terminal (plug-in connection), Connection design in TOP direction
2 conductors, Current measurement
2 conductors, Analog outputs, Output current
Protocol
Other bus systems

Input/Output

Accuracy
± 0.5 % of full scale, Analog outputs
± 0.5 % of full scale, Current measurement
Input
4 Analog inputs (0/4 - 20 mA)
Input current
Max. 100 mA
Load current
Not specified by plug manufacturer
Measured variables
Current
Number of inputs (analog)
4
Number of outputs (analog)
4
Output
4 Analog Outputs (0/4 - 20 mA)
Output current
0 - 20 mA, Analog outputs
Refresh time
1 ms (analog inputs, all channels)
Resistive load
≤ 500 Ω, analog outputs
Value refresh time/cycle time
Min. 1 / 1 ms (per channel / all channels), Analog Inputs

Safety

Explosion safety category for dust
None
Explosion safety category for gas
None
Potential isolation
Analog inputs: no
Power supply, Input: no

Design verification

Equipment heat dissipation, current-dependent Pvid
0 W
Heat dissipation capacity Pdiss
0 W
Heat dissipation per pole, current-dependent Pvid
0.851 W
Rated operational current for specified heat dissipation (In)
0 A
Static heat dissipation, non-current-dependent Pvs
2.58 W
10.2.2 Corrosion resistance
Meets the product standard's requirements.
10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard's requirements.
10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard's requirements.
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects
Meets the product standard's requirements.
10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard's requirements.
10.2.5 Lifting
Does not apply, since the entire switchgear needs to be evaluated.
10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.2.7 Inscriptions
Meets the product standard's requirements.
10.3 Degree of protection of assemblies
Meets the product standard's requirements.
10.4 Clearances and creepage distances
Meets the product standard's requirements.
10.5 Protection against electric shock
Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components
Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections
Is the panel builder's responsibility.
10.8 Connections for external conductors
Is the panel builder's responsibility.
10.9.2 Power-frequency electric strength
Is the panel builder's responsibility.
10.9.3 Impulse withstand voltage
Is the panel builder's responsibility.
10.9.4 Testing of enclosures made of insulating material
Is the panel builder's responsibility.
10.10 Temperature rise
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating
Is the panel builder's responsibility.
10.12 Electromagnetic compatibility
Is the panel builder's responsibility.
10.13 Mechanical function
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.