MMX34AA4D3N0-0 122678 EATON ELECTRIC Inverter M-MAX TF 1.5kW No RF Filter View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

MMX34AA4D3N0-0 122678 EATON ELECTRIC Inverter M-MAX TF 1.5kW No RF Filter

MMX34AA4D3N0-0

122678

EATON-MOELLER

Inverter M-MAX TF 1.5kW - No RF Filter

More details


Home > EATON - MOELLER

Brand new product in its original packaging covered by the warranties and certifications provided by EATON-MOELLER

* This article may be obsolete. Ask for a quotation and we will check if there are any units available. If not, one of our technicians will look for an alternative solution.

If our price is not the best, please ask us for a quote. Ask for a quotation

Best sellers

More info



Range of delivery
Range
M-MAX (MMX)
Rated voltage of employment
3 AC 400 V
Mains voltage (50/60Hz)
ULN V 380 (-15%) - 480 (+10%)
Engine power corresponding
under 400 V, 50 Hz
P kW 1.5
Rated current of employment at a switching frequency of 6 kHz and an ambient air temperature of +50 °C
under 460 V, 60 Hz
P HP Two
Engine powers adapted to the three-phase asynchronous motors tétrapolaires standards, internal cooling and surface area (1500tr/minat 50 Hz and 1800tr/minto 60 Hz)
Rated current job
Ie Has 4.3
Rated current motor
under 400 V, 50 Hz
Ie Has 3.6
under 440 - 480 V, 60 Hz
Ie Has 3.4
Filters for interference suppression
without a filter of interference suppression built-in
Degree of protection
IP20/NEMA 0
Braking unit
unit with internal braking
Size
FS2
Notes
Transition in degree of protection IP21/NEMA 1, → additional Equipment
Technical characteristics
Power part
On the network side
Number of phases
Three-phase (L,1, L2, L3, e.g.)
Mains voltage (50/60Hz)
ULN V 380 (-15%) - 480 (+10%)
Mains voltage UL/CSA (45-66 Hz ± 0%)
ULN V 323 - 528 (±0%)
Rated voltage of employment
3 AC 400 V
Rated current job
Ie Has 4.3
Input current
ILN Has 5.6
Overload current for 60 s every 600 s at 50 °C
Has 6.5
Peak at start-up for 2 s every 20 s at 50 °C
Has 8.6
Leakage current maximum at the ground (PE) without motor
IPE my 25.1
Apparent power
Apparent power in rated service 400 V
S kVA 2.98
Apparent power in rated service 480 V
S kVA 3.57
Engine power corresponding
under 400 V, 50 Hz
P kW 1.5
under 460 V, 60 Hz
P HP Two
Braking torque
Braking torque Standard
max. 30 % MN
Braking torque Braking dc
max. 100% of the rated current of job Ieadjustable ,
Braking torque with external braking resistor
max. 100% of the rated current of job Iewith external resistor
External braking resistor min.
Rmin Ω Fifty five
Activation threshold for the braking transistor
UDC V DC Seven hundred sixty five
Clock frequency
fPWM kHz Six
adjustable 1 - 16 (real)
Power dissipated under current assigned job
PV W 66.4
Performance
% Ninety six
Equipment
Fan (internal, temperature-activated)
Size
FS2
Weight
m kg 0,700
Technical data ETIM 5.0(View criteria)(Hide criteria)
Voltage of the network
V 0 - 480
Network frequency
50/60 Hz
Number of phases at the entrance
Three
Number of phases to the output
Three
Value max. the output frequency
Hz Three hundred twenty
Nominal output voltage
V Four hundred
Output current rating
Has 4.3
Power output to the rated output voltage
kW 1.5
Value max. of output power with load, quadratic in the voltage nomi
kW 1.5
Value max. of the output power with linear load under the voltage-nominal
kW 1.5
With control element
Yes
Permitted use in industrial zones
Yes
uses allowed in the residential areas and tertiary
Not
Supports protocoleTCP/IP
Not
Supports protocol PROFIBUS
Not
Supports CAN protocol
Not
Supports protocol INTERBUS
Not
Support protocol ASI
Not
Supports protocol EIB/KNX
Not
Supports MODBUS protocol
Yes
Supports protocol Data-Highway
Not
Supports protocol DeviceNet
Not
Supports protocol SUCONET
Not
Protocol LON
Not
Protocol for PROFINET IO
Not
Protocol for PROFINET CBA
Not
Supports protocol SERCOS
Not
Protocol for Foundation Fieldbus
Not
Protocol for EtherNet/IP
Not
Protocol for AS-Interface Safety at Work
Not
Protocol for DeviceNet Safety
Not
Protocol INTERBUS Safety
Not
Protocol for PROFIsafe
Not
Protocol for SafetyBUS p
Not
Supporting protocol for other bus systems
Not
Number of interfaces industrial Ethernet
Zero
Number of interface HW-PROFINET
Zero
Number of interfaces serial RS-232
Zero
Number of interfaces serial RS-422
Zero
Number of interfaces serial RS-485
One
Number of interfaces serial TTY
Zero
Number of USB interfaces
Zero
Number of interfaces parallel
Zero
Number of interfaces other
Zero
Optical Interface
Not
With connection to PC
Yes
Chopper (chopper) integrated braking
Not
Operation in 4 quadrants possible
Not
Performance converters
Inverter U
Protection class (IP)
IP20
Height
mm One hundred ninety five
Width
mm Ninety
Depth
mm One hundred five
Relative tolerance of the frequency symmetrical to the network
% Ten
Tolerance relative to the voltage symmetric to the network
% Ten
Approvals
Product Standards UL 508C; CSA-C22.2 No. 14; IEC/EN61800-3; IEC/EN61800-5; CE marking
UL File No. E134360
UL Category Control No. NMMS, NMMS7
CSA File No. UL report applies to both US and Canada
CSA Class No. 3211-06
North America Certification UL listed, certified by UL for use in Canada
Specially designed for North America No.
Suitable for Branch circuits
Max. Voltage Rating 3~ 480 V AC IEC: TN-S UL/CSA: Y (Solidly Grounded Wey)
Degree of Protection IEC: IP20; optionally UL/CSA NEMA 1
Congestion
CAD data
More information on the products (links)
IL04020006Z frequency inverters MMX, sizes 1, 2 and 3
MN04020001Z frequency inverters M-Max, manual

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.