NZM1-XUHIV20LK24DC 284401 EATON ELECTRIC Undervoltage release, 24VDC +2early N/O View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

NZM1-XUHIV20LK24DC 284401 EATON ELECTRIC Undervoltage release, 24VDC +2early N/O

NZM1-XUHIV20LK24DC

284401

EATON-MOELLER

Undervoltage release, 24VDC +2early N/O

NZM1-XUHIV20LK24DC

More details


Low-voltage industrial components > Under voltage coil

Circuit Breakers NZM Accessories

* Brand new product in its original packaging covered by the warranties and certifications provided by EATON-MOELLER

Total price: $147.51
Unit price: $147.51

Quantity Price
1+$147.51
2+$142.30
*This price is per unit and is the net value (not including taxes if applicable).

If our price is not the best, please ask us for a quote. Ask for a quotation

More info



Undervoltage release, 24VDC +2early N/O
Optional accessories for the circuit-breaker series NZM offers a comprehensive portfolio of application options for use world wide. The mounting is always flexible and easy thanks to the modular function groups. Notes: for interlocking and load-shedding circuits, as well as for early-make of the undervoltage release in main-switch applications. For use with Emergency-Stop devices in conjunction with emergency-stop button. when the shunt release is energized, accidental contact with the main contacts of the switch during attempts to switch on is safely prevented. Early make of auxiliary contacts on switching on and off (manual operation): approx. 20ms. Cannot be used in conjunction with NZM...-XR.. remote operator. Undervoltage releases cannot be installed simultaneously with NZM..-XHIV.. early-make auxiliary contact or NZM..-XA.. shunt release. Can be used for: NZM1(-4), N(N/O)1(-4)

Delivery program

Product range
Accessories
Accessories
Undervoltage release
Accessories
Undervoltage release with early-make auxiliary contact
Standard/Approval
UL/CSA, IEC
Construction size
NZM1
Description
Undervoltage release with 2 early-make auxiliary contacts, e.g., for early-make connection of undervoltage release in main switch applications, as well as for interlock and load shedding circuits.
For use with emergency-stop devices in connection with an emergency-stop button.
When the under-voltage trip is switched off, accidental contact with the circuit breaker’s primary contacts is prevented when switched on.
Early make of auxiliary contacts on switching on and off (manual operation): approx. 20 ms
Cannot be used in conjunction with NZM...-XR... remote operator.
Undervoltage releases cannot be installed simultaneously with NZM...-XHIV... early-make auxiliary contact or NZM...-XA... shunt release.
Connection type
Coil terminals with 3 m of loose connection cables
Auxiliary contact terminals wired to terminal block
Auxiliary contacts
with two separate early-make auxiliary contacts
Rated control voltage [Us]
24 V DC V
For use with
NZM1(-4), N(S)1(-4)

Technical data

Undervoltage release
Rated control voltage [Us]DC [Us]
24-24 V DC
Rated control voltage [Us]Rated control voltage [Us]
24 V DC V
Operating rangeDrop-out voltage
0.35 - 0.7 x Us
Operating rangePick-up voltage [x Uc]
0.85 - 1.1
Power consumptionACPick-up AC
1.5 VA
Power consumptionACSealing AC
1.5 VA
Power consumptionDCPick-up DC
0.8 W
Power consumptionDCSealing DC
0.8 W
Maximum opening delay (response time until opening of the main contacts)
19 ms
Minimum command time
10 - 15 ms
Terminal capacities
Solid or flexible conductor, with ferrule
1 x (0,75 - 2,5)
2 x (0,75 - 2,5) mm2
1 x (18 … 14)
2 x (18 … 14) AWG

Design verification as per IEC/EN 61439

IEC/EN 61439 design verification
10.2 Strength of materials and parts10.2.2 Corrosion resistance
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.5 Lifting
Does not apply, since the entire switchgear needs to be evaluated.
10.2 Strength of materials and parts10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.2 Strength of materials and parts10.2.7 Inscriptions
Meets the product standard's requirements.
10.3 Degree of protection of ASSEMBLIES
Does not apply, since the entire switchgear needs to be evaluated.
10.4 Clearances and creepage distances
Meets the product standard's requirements.
10.5 Protection against electric shock
Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components
Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections
Is the panel builder's responsibility.
10.8 Connections for external conductors
Is the panel builder's responsibility.
10.9 Insulation properties10.9.2 Power-frequency electric strength
Is the panel builder's responsibility.
10.9 Insulation properties10.9.3 Impulse withstand voltage
Is the panel builder's responsibility.
10.9 Insulation properties10.9.4 Testing of enclosures made of insulating material
Is the panel builder's responsibility.
10.10 Temperature rise
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.12 Electromagnetic compatibility
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.13 Mechanical function
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.

Technical data ETIM 7.0

Low-voltage industrial components (EG000017) / Under voltage coil (EC001022)
Electric engineering, automation, process control engineering / Low-voltage switch technology / Circuit breaker (LV < 1 kV) / Undervoltage trip ([email protected] [AKF015013])
Rated control supply voltage Us at AC 50HZ
0 - 0 V
Rated control supply voltage Us at AC 60HZ
0 - 0 V
Rated control supply voltage Us at DC
24 - 24 V
Voltage type for actuating
DC
Type of electric connection
Screw connection
Number of contacts as normally open contact
2
Number of contacts as normally closed contact
0
Number of contacts as change-over contact
0
Delayed
No
Suitable for power circuit breaker
Yes
Suitable for off-load switch
Yes
Suitable for motor safety switch
No
Suitable for overload relay
No

Approvals

Product Standards
UL489; CSA-C22.2 No. 5-09; IEC60947, CE marking
UL File No.
E140305
UL Category Control No.
DIHS
CSA File No.
022086
CSA Class No.
1437-01
North America Certification
UL listed, CSA certified

Dimensions

123X305

NZM1-XA(HIV)
NZM1-XU(HIV)(20)
NZM1-XHIV

NZM1-XA(HIV)(L)
NZM1-XU(V)(HIV)(L)(20)
NZM1-XHIV(L)

NZM1-XHIVR

Datasheet - PDF

Title: Size: Type:
NZM1-XUHIV20LK24DC 284401 EN_284401.pdf 198 Kbytes   NZM1-XUHIV20LK24DC  284401 EN_284401.pdf

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.