+IZMX-UVR110AD 123761 EATON MOELLER Undervoltage release 110-125 VAC/DC View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

+IZMX-UVR110AD 123761 EATON MOELLER Undervoltage release 110-125 VAC/DC

+IZMX-UVR110AD

123761

EATON - MOELLER

Undervoltage release 110-125 VAC/DC

More details


Circuit Breakers Electrical Power

* Brand new product in its original packaging covered by the warranties and certifications provided by EATON - MOELLER

* This article is obsolete. Please ask us for a quotation and we will check if there are units available or we will offer you an alternative product.

Related products

More info



Delivery programme
Product range
  Accessories
Accessories
  Remote switching
Accessories
  Undervoltage release
 
  Cannot be combined with a second shunt release.
Maximum operating frequency
Actuations/minute 3
 
  Limited to 3/min due to the high pick-up current for 35 ms.
Please note - the circuit-breaker's switching frequency = 60/h
Rated control voltage
UsV110 - 127 V AC 50/60 Hz
110 - 125 V DC
Operating range
x USFactor0,85 -1,1
max. holding current
InA0.056
max. pick-up current (35ms)
InA8.04
max. sealing power
AC/DCVA/W5
max. pull-in power (35ms)
AC/DCVA/W890
Circuit-breaker total switching time
@ US=100%ms37
For use with
  IZMX16..., IZMX40...
INX16..., INX40...
Notes 

Can be continuously ON (100% DF)

Design verification as per IEC/EN 61439(Show features)(Hide features)
Technical data for design verification
   
Operating ambient temperature min.
 °C-25
Operating ambient temperature max.
 °C70
Technical data ETIM 6.0
Low-voltage industrial components (EG000017) / Under voltage coil (EC001022)
Electric engineering, automation, process control engineering / Low-voltage switch technology / Circuit breaker (LV < 1 kV) / Undervoltage trip ([email protected] [AKF015010])
Rated control supply voltage Us at AC 50HZ
 V110 - 127
Rated control supply voltage Us at AC 60HZ
 V110 - 127
Rated control supply voltage Us at DC
 V110 - 125
Voltage type for actuating
  AC/DC
Type of electric connection
  Flat plug-in connection
Number of contacts as normally open contact
  0
Number of contacts as normally closed contact
  0
Number of contacts as change-over contact
  0
Delayed
  No
Suitable for power circuit breaker
  Yes
Suitable for off-load switch
  Yes
Suitable for motor safety switch
  No
Suitable for overload relay
  No

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

Últimas Opiniones de Nuestros Clientes

Todas las valoraciones que recibimos de los artículos que ofrecemos son reales y están verificadas. Un pequeño gesto, pero de mucho valor. Por eso, te agradecemos ese minuto que inviertes en dejarnos tu opinión y calificación sobre los productos, porque nos ayuda a seguir mejorando y a ofrecerte un servicio de todavía mayor calidad.