LN4-4-1000-I 112017 EATON ELECTRIC Switch-disconnector, 4 p, 1000A, frame size 4 View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

LN4-4-1000-I 112017 EATON ELECTRIC Switch-disconnector, 4 p, 1000A, frame size 4

LN4-4-1000-I

112017

EATON-MOELLER

Switch-disconnector, 4 p, 1000A, frame size 4

LN4-4-1000-I

More details


Circuit Breakers LZM

* Brand new product in its original packaging covered by the warranties and certifications provided by EATON-MOELLER

Total price: $2,219.44
Unit price: $2,219.44

*This price is per unit and is the net value (not including taxes if applicable).

If our price is not the best, please ask us for a quote. Ask for a quotation

More info



Switch-disconnector, 4 p, 1000A, frame size 4

General specifications
Product name
Eaton Moeller series Power Defense molded case switch-disconnector
Part no.
LN4-4-1000-I
EAN
4015081115655
Product Length/Depth
401 millimetre
Product height
207 millimetre
Product width
280 millimetre
Product weight
22 kilogram
Compliances
RoHS conform
Certifications
IEC
Product Tradename
Power Defense
Product Type
Molded case switch-disconnector
Product Sub Type
None
Delivery program
Application
Use in unearthed supply systems at 525 V
Type
Switch-disconnector
Circuit breaker frame type
LN4
Number of poles
Four-pole
Amperage Rating
1000 A
Features
Motor drive optional
Version as maintenance-/service switch
Version as main switch
Version as emergency stop installation
Special features
Busbar tag shroud to VDE 0160 Part 100.Main switch characteristics including positive drive to IEC/EN 60204 and VDE 0113.Isolating characteristics to IEC/EN 60947-3 and VDE 0660.Rated current = rated uninterrupted current: 1000 A
Technical Data - Electrical
Voltage rating
690 V - 690 V
Rated operating voltage (Ue) at AC - max
400 V
Rated insulation voltage (Ui)
1000 V
Rated impulse withstand voltage (Uimp) at auxiliary contacts
6000 V
Rated impulse withstand voltage (Uimp) at main contacts
8000 V
Rated conditional short-circuit current (Iq)
100 kA
Rated operational current
1600 A (690 V AC-1, making and breaking capacity)
1600 A (415 V AC-1, making and breaking capacity)
1600 A (690 V AC-22/23A, making and breaking capacity)
1600 A (415 V AC-22/23A, making and breaking capacity)
Rated permanent current at AC-21, 400 V
0 A
Rated conditional short-circuit current with back-up fuse
80 kA at 690 V
N4-630…1600: 2 x 800 AgGgL
100 kA at 400/415 V
Rated conditional short-circuit current with downstream fuse
80 kA at 690 V
100 kA at 400/415 V
N4-630…1600: 2 x 800 AgGgL
Rated short-time withstand current (Icw)
25 kA
Rated short-time withstand current (t = 0.3 s)
25 kA
Rated short-time withstand current (t = 1 s)
25 kA
Rated operating frequency
50 Hz
Rated short-circuit making capacity Icm at 690 V, 50/60 Hz
53 kA
Rated operating power at AC-3, 400 V
0 kW
Rated operating power at AC-23, 400 V
560 kW
Switching power at 400 V
0 kW
Short-circuit total breaktime
< 10 ms
Short-circuit protective device fuses - max
1600 A gL
Electrical connection type of main circuit
Bolt connection
Number of operations per hour - max
60
Handle type
Rocker lever
Overvoltage category
III
Pollution degree
3
Lifespan, electrical
3000 operations at 400 V AC-1
1000 operations at 690 V AC-3
2000 operations at 400 V AC-3
2000 operations at 690 V AC-1
2000 operations at 415 V AC-3
3000 operations at 415 V AC-1
Technical Data - Mechanical
Mounting Method
Distribution board installation
Fixed
Intermediate mounting
Built-in device fixed built-in technique
Ground mounting
Degree of protection (IP), front side
IP20
Number of auxiliary contacts (change-over contacts)
0
Number of auxiliary contacts (normally closed contacts)
0
Number of auxiliary contacts (normally open contacts)
0
Handle color
Gray
Switch positions
I, +, 0
Special features
Busbar tag shroud to VDE 0160 Part 100.Main switch characteristics including positive drive to IEC/EN 60204 and VDE 0113.Isolating characteristics to IEC/EN 60947-3 and VDE 0660.Rated current = rated uninterrupted current: 1000 A
Lifespan, mechanical
10000 operations
Technical Data - Mechanical - Terminals
Standard terminals
Screw terminal
Terminal capacity (control cable)
0.75 mm² - 1.5 mm² (2x)
0.75 mm² - 2.5 mm² (1x)
Terminal capacity (aluminum stranded conductor/cable)
50 mm² - 240 mm² (4x) at 4-hole tunnel terminal
Terminal capacity (copper busbar)
Min. 25 mm x 5 mm at rear-side 1-hole module plate
Max. 80 mm x 10 mm (2x) at rear-side width extension
Min. 60 mm x 10 mm at rear-side width extension
Min. 25 mm x 5 mm direct at switch rear-side connection
M10 at rear-side screw connection
Max. 50 mm x 10 mm (2x) at rear-side 1-hole module plate
Max. 80 mm x 10 mm (2x) direct at switch rear-side connection
Max. 50 mm x 10 mm (2x) direct at switch rear-side connection
50 mm x 10 mm (2x) at rear-side 2-hole module plate
Terminal capacity (copper solid conductor/cable)
50 mm² - 240 mm² (4x) at 4-hole tunnel terminal
95 mm² - 240 mm² (6x) at rear-side width extension
35 mm² - 185 mm² (4x) at rear-side 2-hole module plate
120 mm² - 300 mm² (1x) at rear-side 1-hole module plate
300 mm² (4x) at rear-side width extension
95 mm² - 185 mm² (2x) at rear-side 2-hole module plate
95 mm² - 300 mm² (2x) at rear-side 1-hole module plate
Terminal capacity (copper stranded conductor/cable)
50 mm² - 185 mm² (4x) direct at switch rear-side connection
120 mm² - 185 mm² (1x) direct at switch rear-side connection
Terminal capacity (copper strip)
10 segments of 50 mm x 1 mm (2x) at 1-hole module plate
10 segments of 80 mm x 1 mm (2x) at rear-side width extension
Max. 10 segments of 50 mm x 1 mm (2x) at rear-side connection (punched)
Max. 10 segments of 32 mm x 1 mm (2x) at flat conductor terminal
Min. 10 segments of 50 mm x 1 mm (2x) at rear-side connection (punched)
Min. 6 segments of 16 mm x 0.8 mm at flat conductor terminal
Design verification as per IEC/EN 61439 - technical data
Rated operational current for specified heat dissipation (In)
1000 A
Equipment heat dissipation, current-dependent
111 W
Design verification as per IEC/EN 61439
10.2.2 Corrosion resistance
Meets the product standard's requirements.
10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard's requirements.
10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard's requirements.
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects
Meets the product standard's requirements.
10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard's requirements.
10.2.5 Lifting
Does not apply, since the entire switchgear needs to be evaluated.
10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.2.7 Inscriptions
Meets the product standard's requirements.
10.3 Degree of protection of assemblies
Does not apply, since the entire switchgear needs to be evaluated.
10.4 Clearances and creepage distances
Meets the product standard's requirements.
10.5 Protection against electric shock
Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components
Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections
Is the panel builder's responsibility.
10.8 Connections for external conductors
Is the panel builder's responsibility.
10.9.2 Power-frequency electric strength
Is the panel builder's responsibility.
10.9.3 Impulse withstand voltage
Is the panel builder's responsibility.
10.9.4 Testing of enclosures made of insulating material
Is the panel builder's responsibility.
10.10 Temperature rise
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.12 Electromagnetic compatibility
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.13 Mechanical function
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
Additional information
Functions
Interlockable
Disconnectors/main switches
Voltage release optional

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.